![Visonic IR-50 Installation Instructions Download Page 2](http://html1.mh-extra.com/html/visonic/ir-50/ir-50_installation-instructions_1033140002.webp)
2
DE1854
B. Mount the base (with the P.C. board) in the selected location
and height for optimum coverage. For surface mounting use
the 2 base rear knockout holes. For corner mounting use the
angled sides knockouts. The unit(s) must be fastened tightly to
the mounting surface to avoid vibrations.
C . To close the front cover (after wiring), insert the legs, located
on the bottom of cover, into their respective slots in the bottom
of the base and close by exerting slight downward.
:LULQJ
A. To route wires into the housing, use either the wiring
knockouts or one of the lower circular mounting knockouts.
B. Wiring the receiver
1) Connect Tamper N.C. terminals
to control panel normally
closed 24h protection zone.
Tamper contact opens when
cover is removed.
Figure 7 - Terminal Block
Wiring - Receiver
2) Connect Relay N.C. terminals to control panel normally
closed burglar protection zone. Relay contacts opens when
an intruder is detected or during power loss.
3) Connect the 12VDC (+) and (-) terminals to 9-16VDC
power source and verify correct polarity. Multiple receivers
(IR-50 only) should be connected in parallel.
C. Wiring the transmitter
The transmitter requires only the connection of the supply
voltage (9 -16 VDC) to the 12VDC (+) and (-) terminals.
Note: It is advisable to use power supply with battery back-up.
$OLJQPHQW
Receiver and transmitter alignment is accomplished with Visible
Beam Locator lights that operate through the upper section of the
receiver’s lens (for IR-150: receiver and the transmitter) (Fig. 6).
The receiver should be aligned horizontally and vertically so that
the LED light is fully visible through the Beam Locator section of
the lens when viewed from the transmitter. The transmitter is then
similarly aligned, using the transmitter Beam Locator light.
Three mode LED selector
The receiver’s LED selector consists of a 4-pin connector and a
jumper which can be inserted to link two pins, enabling three
operational modes:
A. WALK/ALARM (Jumper links pins 1-2) - This mode is used for
walk testing. The LED lights up for 2-3 seconds whenever the
beam is interrupted.
B. ALIGN (Jumper links pins 2-3) - This mode is used for
aligning. The LED lights continuously to enable convenient
observation of the red light in the beam locator lenses (Fig. 6.)
C. OFF (Jumper links pins 3-4) - This mode can be used to
disable the LED after final test is completed, to prevent
unauthorized persons from tracing the direction of the beam.
Note: The LED mode selection does not interfere with alarm relay
operation, which will signal whenever the beam is interrupted.
For IR-150: The LED selector in the transmitter lRT-150 enables
only two operational modes: ALIGN and OFF.
For aligning, move the jumper of the LED selector in both units to
ALIGN. The LEDs should light continuously.
Horizontal Alignment
The field of view of each unit can be adjusted horizontally
approximately 30
°
, by rotating the lens to the left or right. To
adjust, remove the lens-locking devices, located on both sides of
the lens, by pushing them from the inside of the cover. Rotate the
lens carefully to the desired position. Holding firmly in place, insert
locking devices from outside (ridges pointed outward) and firmly
push into place until a click is heard. The transmitter is aligned
similarly, using its Beam Locator light.
For IR-50: To align, look towards the receiver from the transmitter
location. Move to the left and to the right of the transmitter, to
determine the area in which the Beam Locator light on the
receiver is fully visible. Align the receiver's lens, so that the center
of the area in which the Beam Locator light is fully visible will be
approximately at the place where the transmitter is located.
Vertical Adjustment
The P.C. board vertical adjusting scale (IR-150: in both units) and
the plastic pointer on the base indicate the approximate vertical
angle in degrees between the receiver's (for IR-150: receiver’s or
transmitter's) line of sight and the horizontal line of the unit.
To change the vertical adjustment, loosen the screw which
fastens the printed circuit board to the base. Slide the P.C. board
up or down to the desired angle and tighten the screw firmly.
To align the receiver, look toward the receiver from the transmitter
location. Align the receiver (vertically) so that the Beam Locator
light will be fully visible from the floor level below the transmitter
and up to the same distance above the transmitter (provided the
distance between the transmitter and receiver is at least 20 times
larger than their height from the floor). The transmitter is aligned
similarly, using the Beam Locator light on the transmitter.
)LQDO7HVW
The system should be checked at least once a week as follows:
A . Move the LED selector jumper to 'WALK' position. Replace
the receiver front cover [IR-50: receiver(s)]. The LED should
go off, indicating correct alignment of the receiver.
B. Walk-test by crossing the path between the transmitter and
receiver [IR-50: receiver(s)]. The receiver LED should light for
2-3 seconds indicating alarm condition caused by interruption
of infrared beam barrier. This test should be performed with all
fluorescent lights at the protected area turned on.
C . Determine the signal margin by slowly covering the receiver
lens from the bottom upward (using a piece of cardboard) until
the LED lights up. The ratio between the size of the covered
lens area and the total lens area (excluding the Beam Locator
area) indicates the signal margin of the system. If alignment is
correct, the signal margin should be more than 35 percent.
D . Move the jumpers (IR-150: in both units) from 'WALK' to 'OFF'
position to disable the LED and prevent unauthorized persons
from ascertaining the path(s) of the infrared beam barrier(s).
The user should be instructed to cross the infrared barrier to
assure an alarm output prior to each system arming.
Figure 8. Printed Circuit Board
$YRLGLQJ5HIOHFWHG%HDP3DWKV
Eliminate reflected beams as follows:
A. For IR-50 only: Apply piece of black insulation tape on inner
side of transmitter window, to narrow the transmitter beam and
allow emission of infrared energy only in the receiver direction.
B. Change the receiver alignment (for IR-150: of receiver and
transmitter), adjusting them away from the reflecting surface.
C. Reduce receiver’s sensitivity by lens partial covering (from
inside). When the reflected beam barrier is eliminated recheck
system signal margin (para. 3.5c.).
VISONIC LTD (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): 10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISONIC LTD. (UK): UNIT 1, STRATTON PARK, DUNTON LANE BIGGLESWADE, BEDS. SG18 8QS. PHONE: (01767) 600857 FAX: (01767) 601098
VISONIC LTD. 1998 IR-50 / IR-150 D-1851-0 NEW: DE1851- (REV. 1, 7/98). WARRANTY STATEMENT IS AVAILABLE UPON REQUEST.