Visonic IR-50 Installation Instructions Download Page 1

DE1851

1

,5,5

Indoor Photo-Electric Infrared Beam Barrier

Installation Instructions

,1752'8&7,21

IR-50 and IR-150 are pulse-modulated photoelectric infrared
beam barrier designed for indoor residential, commercial and
industrial applications. The system consists of a transmitter
producing a wide angle (IR-50) or concentrated (IR-150) invisible
infrared beam towards a narrow-angle receiver. Visible Beam
Locator light in the receiver (IR-50) or in the transmitter and the
receiver (IR-150), provide quick and easy alignment without
special tools or test equipment.
The transmitted beam is generated by 2 powerful infrared LEDs.
The 40

°

 wide angle beam of IR-50 allows multiple receiver

installations using a single transmitter. The 6

°

 receiver field of

view provides a large safety margin to prevent false alarms. Yet it
is narrow enough to eliminate reception of reflected beam. Internal
built-in optical filter prevents unwanted light penetration, other
than the infrared wavelength.

The system is immune to
fluorescent radiation, flickering
lights and indirect sunlight.
State-of-the-art electronic
circuitry provides protection
against RF interference and
supply voltage transients.
The transmitter emits an invisible
beam, to the receiver. When an
intruder crosses this beam
barrier, the receiver’s internal
alarm relay deenergizes.

IR-50 Transmitter & Receiver

Note: External view of IR-150
transmitter & receiver is  similar.

The receiver’s walk test LED lights at the same time (when LED
selector is in Walk position, see par. 3.4). After crossing, the relay
again energizes and the LED extinguishes.

63(&,),&$7,216

FEATURE

IR-50

IR-150

OPTICAL
Range (**)

Up to 50m (150 ft)

Up to 150m (500 ft)

Transmitter beam width

40

°

 (*)

6

°

 (*)

Receiver field of view

6

°

(*)

Adjustment

Ve10

°

 to 20

°

. Horizontal 30

°

.

Beam Locators

Visible Beam Locator built into receiver and transmitter

ELECTRICAL
Voltage

9 - 16VDC (protected against reverse polarity)

Transmitter current

20mA

15mA

Receiver current

15mA

Relay output

Normally closed (fail-safe) contacts. 18 ohm resistor in

series with contacts. Rating - 0.5A resistive/24 VDC.

Alarm period

2 - 3 seconds

Tamper contacts

Normally closed. Rating - 0.5A resistive/24 VDC.

LED

Three selectable operation modes

FEATURE

IR-50

IR-150

Infrared source

Long-life Gallium Arsenide LED

Infrared sensor

PIN photodiode

Transmitter Frequency

1 kHz, 10 microsecond pulse width

IR wavelength

950 nm

Receiver type (Qty.)

IRR-50 (one or multiple)

IRR-150 (one)

ENVIRONMENTAL
Operating temperature

-10

°

C to 50

°

C (14

°

F to 122

°

F)

Storage temperature

-20

°

C to 60

°

C (-4

°

F to 140

°

F)

PHYSICAL
Dimensions

120 x 70 x 48 mm (4.7 x 2.7 x 1.9 in)

Weight

220 g (0.48 lb)

Colors

Dark beige standard

cream/ white also available

Dark beige or standard

white

* Typical, horizontal and vertical.

** distance between transmitter to receiver

 Figure 1A. IR-50 Side View Beam Pattern

Figure 1B. IR-50 Top View - Multiple

Receivers

       Figure 2. IR-150 View Beam Pattern

,167$//$7,21

6HOHFWLQJ0RXQWLQJ/RFDWLRQ

A. Select mounting locations / height for the transmitter and

receiver(s) so that an intruder will cross the beam(s). The
receiver and transmitter should be mounted facing each other,
and their angular back housing allow installation directly onto a
wall (surface mount), or in a corner. They may also be
flush-mounted using optional bracket SRF-201. (Fig. 5).

  B .  Prevent receiver’s lens exposure to direct sun light, to prevent

false alarm.

  C .  For maximum reliability, locate the receiver as far as possible

from fluorescent light or flickering lights.

NOTE: The transmitter unit is not sensitive to any of the above
disturbance sources and may be placed wherever desired.

0RXQWLQJ

A. Insert a small screw driver into the slot on top of the unit, press

lightly down and remove the cover.

Figure 3. Cover Removal

Figure 4. Cover Replacement

Figure 5. Flush Mounting

Bracket SRF-201

Figure 6. Beam Locator Light

Side View

Top View