D-303424 GSD-441 PG2 Installation Instructions
3
3. PREPARATION FOR USE
3.1 The LED Functions
Once the unit is plugged into the wall outlet, the green power indicator flashes indicating that power is present and the unit is working. After
an initial ten minute warm-up period, the unit will start the process of continually sampling the air around it.
Table 1.
LED functions
LED Function
Green
Flashing:
During the first ten minutes (after power connection) the green LED flashes (stabilization time).
Constant light:
The equipment is ready for operation: "Power ON".
Orange
Illuminates in the event of trouble and emits a lengthy buzzer sound.
Red (alarm)
Flashes and a supplementary acoustic signal generator (transducer) sounds intermittently in the event of an alarm.
3.2 Test Button and Muting Switch
Press down on the Test / Silent button (see Figure 2) to test the operation of the indicators. The red and orange LEDs will flash and an
acoustic signal tone will sound intermittently. This action should be performed once a
week
. Use the Test / Silent button (see Figure 2) to
switch off the acoustic alarm tone in the event of an alarm. The red LED will continue to flash and a short signal tone will sound
approximately every 45 seconds.
Note:
Do not test the GSD-441 PG2 using a gas lighter.
Note:
In the event of a gas leakage, the smell of the gas may be in the air before the detector activates the alarm.
4. MISCELLANEOUS COMMENTS
Visonic Ltd. wireless systems are very reliable and are tested to high standards. However, due to low transmitting power and limited range
(required by FCC and other regulatory authorities), there are some limitations to be considered:
A.
Receivers may be blocked by radio signals occurring on or near their operating frequencies, regardless of the digital code used.
B.
A receiver responds only to one transmitted signal at a time.
C.
Wireless devices should be tested regularly to determine whether there are sources of interference and to protect against faults.
D.
It is recommended to unplug the detector from the electricity mains before cleaning. Clean only using a dry cloth. Do not clean using a liquid
substance. Clean externally surfaces only.
The user is cautioned that changes or modifications to the unit, not expressly approved by Visonic Ltd., could void the user’s FCC or other
authority to operate the equipment
.
5. COMPLIANCE WITH STANDARDS
FCC part 15 statement:
The digital circuit of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
IC statement:
This device complies with Part 15 of the FCC Rules and with Industry Canada license-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.
WARNING!
To comply with FCC and IC RF exposure compliance requirements, the device should be located at a distance of at least 20 cm from all
persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other
antenna or transmitter.