Visonic CL-8 Installation Instructions Manual Download Page 8

8

DE6205

$SSHQGL[%3URJUDPPLQJ6XPPDU\

Important!  First access to the programming menu is gained through the factory default master code 1234. After programming, User
Code No. 01 becomes the master code.

No.

Function

Keying Format

Format Explanation and Correct Response

1

Access to
Programming
Menu

[

❋❋

 

Master Code 

❋❋

]

 •  

The green LED starts to flash slowly - the programming

 •  

menu is active!

2

Deleting all
previous
User Codes

[4] [

❋❋

]# [Master Code]#

 •  

After pressing [4] - rapid flashing;

 •  

[

❋❋

] deletes all user codes except for code No. 01;

 •  

After keying [

❋❋

]# - steady light for 2 seconds and then rapid flashing

 •  

After Keying [Master Code]# - steady light for 2 seconds and then
slow flashing.

3

Relay timing

[2] [TT]#

 •  

After pressing [2] - rapid flashing;

 •  

[TT]   = 01 to 98 seconds; 99 selects the toggle mode, in which a user
code will latch or unlatch the relay;

 •  

After keying [TT]# -  steady light for 2 seconds and then slow flashing.

4

Selecting
AUX output
operating
mode

[3] [M]#

 •  

After pressing [3] - rapid flashing;

 •  

[M]   =  a code specifying the operating mode of the AUX output
(selected from Table 4, page 13).

 •  

After keying [M]# -  steady light for 2 seconds and then slow flashing.

5

Defining an
AMBUSH
digit

[5] [A]#

 •  

After pressing [5] - rapid flashing;

 •  

[A]   = Ambush digit, 0 to 9 (see note C below)

 •  

After keying [A]# -  steady light for 2 seconds and then slow flashing.

6

Deleting the
AMBUSH
digit

[5] [

]#

 •  

After pressing [5] - rapid flashing;

 •  

[

]   = Deletes the Ambush digit

 •  

After keying [

]# -  steady light for 2 seconds and then slow flashing.

7

Programming
user codes
(prepare a
list - see
Appendix A)

[1] [NN]# [C]# [C]# [F]#

 •  

After pressing [1] - rapid flashing;

 •  

[NN]   =  the serial number of the code user, 01 to 56

 •  

After entering [NN]# -  steady light for 2 seconds and then rapid
flashing.

 •  

[C]   =  the access code allocated to this user, 1 to 8 digits

 •  

After entering [C]# -  steady light for 2 seconds and then rapid
flashing.

 •  

Repeat  [C]# for verification; the LED responds as before.

 •  

[F]  = a code defining which outputs will be tripped by this user code

 •  

1: Authorization to trip the relay only

 •  

2: Authorization to trip the AUX output only

 •  

3: Authorization to trip both  relay and the AUX output

 •  

After entering [F] - steady light for 2 seconds and then slow flashing.

8

Deleting
individual
user codes

[4] [NN]# [Master Code]#

 •  

After pressing [4] - rapid flashing;

 •  

[NN] = the serial number of the code user, 02 to 56

 •  

After entering [NN]# - steady light for 2 seconds and then rapid
flashing

 •  

After entering [Master Code]# - steady light for 2 seconds and then
slow flashing.

Notes:
A. Quit programming by pressing [#] when the green LED flashes slowly.
B. If, while entering data, the green LED responds by going out for 3 seconds instead of lighting for 2 seconds, the data has not been accepted.

Press [

] and repeat the entire stage from the beginning.

C. An AMBUSH digit can not be used with 8-digit user codes, and should not be identical with the last digit in any code.
D. The PANIC output is tripped by pressing [

] and [#] simultaneously.

Table 2. Auxiliary Output Operating Modes

Mode

Description

1

Pulsed for 1 second by every user code authorized to operate the auxiliary output.

2

Toggled (latch/unlatch) by every user code authorized to operate the auxiliary output.

3

Latches by user codes authorized to trip the auxiliary output, unlatches by entry of any user code.

4

Latches by user codes authorized to trip the auxiliary output, unlatches by pressing [

*

].

5

Turned on for ten seconds by pressing any key.

6

Oscillates at the rate of 1 Hz after 3 consecutive code errors. This condition will persist for 10 minutes, and may be reset only
by entering a valid user code (resetting is possible only after the first 30 seconds, during which the keypad will be locked out a
result of the 3 code errors).

7

Turned on by pressing 1 and 3 simultaneously. Remains on while either key is pressed.

Summary of Contents for CL-8

Page 1: ...NIC signal In addition the CL 8 is virtually impossible to defeat by unauthorized people who try to discover a correct code by trial and error a penalty timer locks out the keypad for 30 seconds after three consecutive inputs of erroneous codes Model CL 8A with an extended operating temperature range is supplied for use in uncontrolled temperature environments Model CL 8A EXT is designed to operat...

Page 2: ...back cover Make no splices within the unit and avoid contact between uninsulated wires and the printed circuit board RQQHFWLRQV LULQJ IMPORTANT Before wiring be sure to set jumper JP3 in the position that corresponds with the power source you are using 9 6 Volts mount the jumper across the two pins of JP3 22 26 Volts remove the jumper or mount it on a single pin of JP3 The connections to the termi...

Page 3: ...ile the green LED is flashing slowly causes the green LED to start flashing rapidly The desired value should then be entered followed by the end of data character D Functions 2 3 and 5 on the menu are single stage programming operations If the correct data is entered followed by the green LED lights steadily for 2 seconds and then resumes flashing slowly indicates return to the menu E User Code pr...

Page 4: ...horized to operate the auxiliary output 2 Toggled latch unlatch by every user code authorized to operate the auxiliary output 3 Operated concurrently with the relay timer but stays enabled 5 seconds more after the relay is de energized operation time TT 5 seconds If the relay toggle mode has been selected TT 99 the auxiliary output will be turned on for 5 seconds each time the relay is toggled 4 L...

Page 5: ...rogramming ensure that the green LED is flashing slowly then press This will restore the keypad to normal operation HOHWLQJ XVHU FRGHV A Access the programming menu by entering master code With the programming menu active the green LED will flash slowly B Enter 4 to select the user code deleting function The green LED will respond by flashing rapidly indicating that the keypad is ready to receive ...

Page 6: ...anyone other than the Manufacturer This warranty is exclusive and expressly in lieu of all other warranties obligations or liabilities whether written oral express or implied including any warranty of merchantability or fitness for a particular purpose or otherwise In no case shall the Manufacturer be liable to anyone for any consequential or incidental damages for breach of this warranty or any o...

Page 7: ...7 SSHQGL 8VHU RGH 3URJUDPPLQJ KDUW DATE USER NAME FUNC TION USER NUMBER SEPA R ATING CHAR NEW USER CODE 1 8 DIGITS SEPA RATING CHAR REPEAT USER CODE FOR VERIFICATION SEPA RATING CHAR TRIP CODE END OF DATA CHAR ...

Page 8: ...onds and then rapid flashing Repeat C for verification the LED responds as before F a code defining which outputs will be tripped by this user code 1 Authorization to trip the relay only 2 Authorization to trip the AUX output only 3 Authorization to trip both relay and the AUX output After entering F steady light for 2 seconds and then slow flashing 8 Deleting individual user codes 4 NN MasterCode...

Reviews: