8
DE6205
$SSHQGL[%3URJUDPPLQJ6XPPDU\
Important! First access to the programming menu is gained through the factory default master code 1234. After programming, User
Code No. 01 becomes the master code.
No.
Function
Keying Format
Format Explanation and Correct Response
1
Access to
Programming
Menu
[
❋❋
Master Code
❋❋
]
•
The green LED starts to flash slowly - the programming
•
menu is active!
2
Deleting all
previous
User Codes
[4] [
❋❋
]# [Master Code]#
•
After pressing [4] - rapid flashing;
•
[
❋❋
] deletes all user codes except for code No. 01;
•
After keying [
❋❋
]# - steady light for 2 seconds and then rapid flashing
•
After Keying [Master Code]# - steady light for 2 seconds and then
slow flashing.
3
Relay timing
[2] [TT]#
•
After pressing [2] - rapid flashing;
•
[TT] = 01 to 98 seconds; 99 selects the toggle mode, in which a user
code will latch or unlatch the relay;
•
After keying [TT]# - steady light for 2 seconds and then slow flashing.
4
Selecting
AUX output
operating
mode
[3] [M]#
•
After pressing [3] - rapid flashing;
•
[M] = a code specifying the operating mode of the AUX output
(selected from Table 4, page 13).
•
After keying [M]# - steady light for 2 seconds and then slow flashing.
5
Defining an
AMBUSH
digit
[5] [A]#
•
After pressing [5] - rapid flashing;
•
[A] = Ambush digit, 0 to 9 (see note C below)
•
After keying [A]# - steady light for 2 seconds and then slow flashing.
6
Deleting the
AMBUSH
digit
[5] [
❋
]#
•
After pressing [5] - rapid flashing;
•
[
❋
] = Deletes the Ambush digit
•
After keying [
❋
]# - steady light for 2 seconds and then slow flashing.
7
Programming
user codes
(prepare a
list - see
Appendix A)
[1] [NN]# [C]# [C]# [F]#
•
After pressing [1] - rapid flashing;
•
[NN] = the serial number of the code user, 01 to 56
•
After entering [NN]# - steady light for 2 seconds and then rapid
flashing.
•
[C] = the access code allocated to this user, 1 to 8 digits
•
After entering [C]# - steady light for 2 seconds and then rapid
flashing.
•
Repeat [C]# for verification; the LED responds as before.
•
[F] = a code defining which outputs will be tripped by this user code
•
1: Authorization to trip the relay only
•
2: Authorization to trip the AUX output only
•
3: Authorization to trip both relay and the AUX output
•
After entering [F] - steady light for 2 seconds and then slow flashing.
8
Deleting
individual
user codes
[4] [NN]# [Master Code]#
•
After pressing [4] - rapid flashing;
•
[NN] = the serial number of the code user, 02 to 56
•
After entering [NN]# - steady light for 2 seconds and then rapid
flashing
•
After entering [Master Code]# - steady light for 2 seconds and then
slow flashing.
Notes:
A. Quit programming by pressing [#] when the green LED flashes slowly.
B. If, while entering data, the green LED responds by going out for 3 seconds instead of lighting for 2 seconds, the data has not been accepted.
Press [
❋
] and repeat the entire stage from the beginning.
C. An AMBUSH digit can not be used with 8-digit user codes, and should not be identical with the last digit in any code.
D. The PANIC output is tripped by pressing [
❋
] and [#] simultaneously.
Table 2. Auxiliary Output Operating Modes
Mode
Description
1
Pulsed for 1 second by every user code authorized to operate the auxiliary output.
2
Toggled (latch/unlatch) by every user code authorized to operate the auxiliary output.
3
Latches by user codes authorized to trip the auxiliary output, unlatches by entry of any user code.
4
Latches by user codes authorized to trip the auxiliary output, unlatches by pressing [
*
].
5
Turned on for ten seconds by pressing any key.
6
Oscillates at the rate of 1 Hz after 3 consecutive code errors. This condition will persist for 10 minutes, and may be reset only
by entering a valid user code (resetting is possible only after the first 30 seconds, during which the keypad will be locked out a
result of the 3 code errors).
7
Turned on by pressing 1 and 3 simultaneously. Remains on while either key is pressed.