Enter programming 

Menu 

Operation steps 

Description 

Default 

value 

(1-99)# 

Alarming time range: 1-99 min 

51 

(0-255)# 

Set device number 

52 

(26-58)# 

Wiegand output

26-58 bits 

26 

53 

0# 

Keypad transmission format 4 bits 

1# 

Keypad transmission format 8 bits 

2# 

Virtual card number output 

62 

0# 

Disable light indicator 

1# 

Enable light indicator 

63 

0# 

Disable the keypad backlight 

1# 

Enable the keypad backlight 

(2-99)# 

Time of keypad backlight: 2-99 sec 

64 

0# 

Disable buzzer 

1# 

Enable buzzer 

9.

Admin Card Operation

9.1  Add Card 

Read admin add card , Read the 1

st

 user card      Read the 2

nd

 user card …,Read admin add card   

Note:

 The add card is used to add card users continuously and quickly. When you read the admin add card at the first time, 

you will hear short "BEEP" sounds twice and the indicator light turns orange, it means you have entered into add user 
programming, when you read the admin add card at the second time, you will hear long "BEEP" sound once and the 
indicator light turns red, it means you have exited the add user programming

9.2  Delete Card 

Read admin delete card , Read the 1

st

 user card      Read the 2

nd

 user card … , Read admin delete card   

Note:

 The delete card is used to delete card users continuously and quickly. When you read the admin delete card at the 

first time, you will hear short "BEEP" sounds twice and the indicator light turns orange, it means you have entered into 
delete user programming, when you read the admin delete card at the second time, you will hear long "BEEP" sound once, 
the indicator light turns red, it means you have exited the delete user programming. 

Summary of Contents for 560780

Page 1: ...1 p n 560780 p n 560781 Keypad Fingerprint Access Control User Manual Please read and understand this instruction completely before installation or operation...

Page 2: ...adjusted by user Support seven access ways Support admin add card and admin delete card 10 000 card users and 600 fingerprint userss 3 Technical Specifications Operating Voltage DC 12 24V Standby Curr...

Page 3: ...ional 4 Yellow OPEN BEEP Exit button input end Beeper input as reader mode 5 Brown D_IN LED Door contact switch input LED input as reader mode optional 6 Red 12V Positive power supply or AC power supp...

Page 4: ...4 6 2 Special Power Supply Note The door contact and alarm function are optional 6 3 Reader Mode...

Page 5: ...tor flash slowly Enter setting status Orange Unlocking Green Buzzer alarm Red indicator flash quickly Alarm 8 Admin Menu 8 1 Standalone Mode Settings Device Management Enter programming Men u Operatio...

Page 6: ...nts to a card Maximum 2 fingerprints 13 Press ID number press 8 or 10 digits card number input card quantity Add conductive number card Delete users 21 Read card Input a fingerprint once Delete card u...

Page 7: ...gs Enter programming Menu Operation steps Description Default value Press Admin code Default admin code is 999999 00 New admin code new admin code Change admin code 999999 01 Read card Input a fingerp...

Page 8: ...d the admin add card at the first time you will hear short BEEP sounds twice and the indicator light turns orange it means you have entered into add user programming when you read the admin add card a...

Page 9: ...default code 1234 11 Other Operation 11 1 Remove Alarm Read admin card or Read valid user card or Input valid fingerprint or Press admin code Note When the alarm is activated user can remove the alarm...

Reviews: