3
The VisionLINE Taurus may require an insulating Floor Protector depending on the installation type. It is
tested and complies with the minimum Floor Protector requirements of
AS/NZS 2918:2018
. See below
for Hearth specifications.
Note:
▪ The minimum Floor Protector sizes are specified in the clearance chart, see Table 1 & 2.
▪ A Floor Protector can include ceramic tiles with grouted joints fixed directly onto a wooden floor or a
Steel panel or any other non combustible material laid directly onto a wooden floor.
▪ If installed directly onto a concrete slab, the concrete slab can be considered as the floor protector,
but must maintain the minimum measurement listed.
D
ra
w
in
g
n
o
t
to
s
c
a
le
PARALLEL POSITIONING
Fig. 1
A
E
B
F
D
C
G
Hearth Thickness - 6mm thick hearth when unit is installed on optional raised wood storage
base
* When optional rear heat shield is attached to the appliance, the rear wall clearance reduces
to 200mm to the shield from a combustible wall.
If being installed against a fully non-combustible wall - 50mm spacing is recommended for
servicing access.
** See FIG 3 on page 5
Using AU Default Flue kit (Solid 8” or Mesh)
TAURUS-AU
A
Min. Clearance from firebox to rear wall
450mm*
B
Min. Clearance from firebox to side wall
475mm
C
Min. Distance from firebox opening to floor protector front
600mm**
D
Min distance from firebox to floor protector side
95mm
E
Min distance from centre of flue to side wall
996mm
F
Depth of floor protector
1040mm
G
Width of floor protector
1230mm