background image

Maintenance Kit for an Auto Document Feeder (ADF) with Flatbed Scanner 

1

 

This Kit Contains 

  1 Bottle of Streak-Free De-Ionized Cleaning Solution 

  10 Lint-Free Dry Cleaning Cloths (White) 

  5 Dry Cleaning Cloths (Blue) 

  3 Scan Through Staticide Wipes 

  10 Isopropyl Alcohol Pre-Moistened Cleaning Wipes 

  2 ADF Pad Assemblies 

 Cleaning 

Instructions 

 

Maintenance  

Instructions 

 

 

 

 

 

 

  Dry Cleaning Cloth & Cleaning Solution (Flatbed Only) 

  Spray the flatbed glass with the De-Ionized Cleaning Solution 

  Wipe the glass clean using a lint-free dry cloth (white) 

  Clean the ADF scan frame (small strip of glass with a white 

frame and is the 

only

 area where ADF images are captured) 

  Spray the cleaning solution onto a dry cleaning cloth (blue) to 

clean the outside of the scanner and the cables 

 

  Scan-Through Staticide Wipes (ADF Only) 

  Pre-moistened 8.5x11 pads; keep sealed until use 

  Open the package and take out the pre-moistened pad 

  Unfold the pad and place in the ADF 

  Scan the pad as you would a regular piece of paper 

  Take the pad from the output bed and repeat the scan 

process 4 additional times then delete resulting scan images 

 

  Pre-Moistened Cleaning Wipes 

  Use these wipes between Staticide Scan Through cleanings 

  Open the ADF door and wipe down all plastic surfaces 

2

  

  Wipe and rotate the rollers to ensure the entire surface of  

each roller is clean, wipe down the ADF pad 

 

DO NOT vigorously rub these across the rollers

 

 

  ADF Pad Assemblies 

  ADF Pads push the paper against the main pick-up roller and 

is a user replaceable, consumable part 

  Each pad can be used for up to 20,000 

3

 scans  

  Open the scanner and remove the ADF Pad by pinching the 

plastic clips on either side of the metal bar, place a new pad 
in the scanner, press on the metal bar until it snaps into place 

 

Note: The scanner should be powered off for all cleaning methods except for when 
using the Staticide Pads. 

The contents of this kit should be kept in a clean, dry area and out of the reach of children. 

2

 Do not attempt to clean the black paper-sensor arm, wipe gently around this area without touching the paper 

sensor. 

3

 This number varies based on scanner model, paper weight, paper texture, size of scan batches and frequency 

of scanning. 