Suggestion of the Smoke Detector Location:

 

       

         

 

         

 

 

 

 

 

 

Operation 

 

1. 

Power-on Mode: 

1) Install the battery into the module 2) The detector will emit a 

beep in 0.5 second and the three LEDs will flash once quickly. 3) Close the bracket. 
The CO detector will alarm once remove the bracket.     

2. 

Stand-by Mode:

 The Green LED flashes one time every 60 seconds. 

3. 

Alarm Mode (It

’s the status when the alarm is triggered.):

 If a certain density of 

CO is detected, an audible alarm with 4 beeps, pause 5 seconds and 4 beeps will 
occure. The red LED will flash continuously and rapidly. Meanwhile, the CO 
detector will send an alarm report (Alarm type:0x02, Level:0xFF) to the user

’s 

controller and also the CO dectecor will send an alarm report(Alarm type: 0x02, 
Level: 0x00) while the alarm off. 

4. 

Error Mode:

 If the CO detector beep once and yellow LED flash three times every 

minute, it indicates the CO detector is not working properly. Please require to 
repaire or service.   

5. 

Low battery warning Mode:

 The yellow LED will flash once every minute with a 

“beep” sound. 

6. 

Low sensitivity Mode:

 The yellow LED will flash twice every minute with a 

“beep” 

sound. It indicates the CO detector has internal problem, please replace the unit. 

7. 

Tamper Mode:

 The yellow LED will go solid and the detector will emit a short beep 

every minute untill the CO detector is mounted back to the bracket properly. 

8. 

End of life signal Mode: 

The yellow LED will flash four times every minute with a 

short 

“beep” sound. It indicates the CO detector is reaching to the end of useful life, 

please replace with a new unit.

 

9. 

Testing Mode: 

Test the alarm by pushing test switch

 

until the user hear 4 short 

beeps and three LEDs flash synchronously in five senconds. Then, the CO detector 
will send an alarm report (Alarm type:0x02, Level:0xFF) to the user

’s controller and 

also the CO dectecor will send an alarm report (Alarm type: 0x02, Level: 0x00) 
while the alarm off. Please note if the CO detector only beep once and yellow LED 
falsh three times every minute, it indicates the CO detector is not working properly. 
Please require to repair or service.

         

 

10. 

Battery Power indicator:

 The detector will report the current status of battery 

capcity to the user

’s contorller. 

11. 

Silence Mode: 

The user could press the test switch to get into silence mode to turn 

off the alarm temporarily when the CO detector alarm. Meanwhile, the red LED will 
flash continually. The silence function will automatically turn into normal operation if 
the CO concentration around the CO detector is still at alarming level after 4 
minutes of silence mode.   

 

    Federal Communications Commission Statement 

 

This equipment has been followed to comply with the limits for a Class B digital device, pursuant to 
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction, may cause harmful 
interference to radio communications. However, there is no guarantee that interference will not occur 
in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
and correct the interferene by one of the following measures: 
-- Reorient or relocate the receiving antenna, 
-- Increase the separation between the equipment and receiver, 
-- Connect the equipment into and outlet on a circuit different from that to which the receiver is 
connected. 
-- Consult the dealer or an experienced radio/TV technician for help. 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undersired operation. 
FCC Caution: Any changes or modifications not expressly approved by the party responsible for 
compliance could void the user

’s authority to operate this equipment. 

 

Limited Warranty 

 

Vision Guarantees that every wireless CO detector is free from physical defects in material and 
workmanship under normal use for one year from the date of purchase. If the product proves 
defective during this one-year warranty period, Vision will replace it free of charge. Vision does not 
issue any refunds. This warranty is extended to the original end user purchase only and is not 
transferable. This warranty does not apply to: (1) damage to units caused by accident, dropping or 
abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair, 
opened, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) 
damages exceeding the cost of the product; (5) transit damage, initial installation costs, removal cost, 
or reinstallation cost. 
For information on addional devices, plesae visit us at 

www.visionsecurity.com.tw

 

 

WARNING:

 

The carbon monoxide sensing unit

 has only 5-year limited life. For the 

security issue, we strongly recommend the user to change whole the CO detector after 
4-year usage.   

 

 