Introduction
Thanks for choosing the Vision’s Power Monitor or On/Off Module of the home automation device. This
Power Monitor or On/Off Module is a Z-Wave
TM
enabled device (interoperable, two-way RF mesh
networking technology) and is fully compatible with any Z-Wave
TM
enabled network. Every main powered
Z-Wave
TM
enabled device acts as a signal repeater and multiple devices result in more possible
transmission routes, which helps eliminate “RF dead-sport”.
Z-Wave
TM
enabled devices displaying the Z-Wave
TM
logo can also be used with it regardless of the
manufacturer, and ours can also be used in other manufacturer’s Z-Wave
TM
enabled networks. This
module will send On/Off signal to the appliance that attached to this module by receiving Z-Wave
TM
signal from controller or manually switch. It also sends the energy consumption (ZL7261 only) to the
controller when it requests. With special design, this module won’t interfere the other power outlet when
plug into the AC outlet. This module also acts as repeater (supporting FLiRS).
Product Description and Specification
Specification:
Package Content:
Protocol: Z-Wave
TM
(ZM5202)
Frequency:
868.42 MHz (ZL7201CN/DE/FR/IT / ZL7261CN/DE/FR/IT)
869.00 MHz (ZL7201RU / ZL7261RU)
908.40 MHz (ZL7201CL/US / ZL7261CL/US)
919.70 MHz (ZL7201KR / ZL7261KR)
922-926MHz (ZL7201JP / ZL7261JP)
Operating Temp. -15
°
C~ 60
°
C (-5
°
F~ 140
°
F)
Operating Voltage: AC 100V~230V
Operating Range: Up to 100 feet (about 30m)
Data Rate: Up to 9.6k/40k/100kbps
Application: Indoor use
Max Loading
1pc
Power Monitor or On/Off Module
1pc User Manual
Type B: 110V/15A/1600W (Resistive)
220V15A/3200W (Resistive)
Type E, F & L: 230V/10A/2300W (Resistive)
Z-Wave
™
™
™
™
Command Class:
COMMAND_CLASS_APPLICATION_STATUS
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_METER_V4 (ZL7261 only)
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_PROTECTION (ZL7201 only)
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SWITCH_ALL
COMMAND_CLASS_SWITCH_BINARY mapping COMMAND-CLASS_BASIC
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_ZWAVEPLUS_INFO
Operation
If you are installing the entire Z-Wave
TM
system for the first time, please refer to the
installation guide of Z-Wave
TM
Interface Controller before installing
ZL7261 or ZL7201.
1.
For “
Inclusion
” in (adding to) a network: Put the Z-Wave
TM
Interface Controller into
“inclusion” mode, and following its instruction to add the
ZL7261 or ZL7201
into your
controller. To get in the “Inclusion” mode, the distance between
ZL7261 or ZL7201
and
controller is suggested to be in one meter. By power up to get included for first time, or
press the Program switch
3 times within 2 seconds to be included.
For “
Exclusion
” from (removing from) a network: Set up the Z-Wave
TM
Interface
Controller into “exclusion” mode, and following its instruction to delete the
ZL7261 or
ZL7201
from your controller. Press the Program Switch
3 times within 2 seconds to
be excluded.
For “Association”: the Z-Wave
TM
interface controller set “Association”, and following its
instruction to associate the
ZL7261 or ZL7201
with other device. Support one group (5
nodes).
ZL7261 or
ZL7201
will report back every time ON and OFF status, also it will
reports every notification to all devices in the association group.
2. For “Meter Supported Get” (ZL7261 only): the Z-Wave
TM
Interface Controller or Gateway
can send “Meter Get” command with any of the following supported scales, and the
ZL7261 will report back with the energy consumption values for the requested scale:
Scale: 0x00-kWh(Default);
0x01-kVAh
0x02-W
0X04-V
0X05-A
0X06-Power Factor.