background image

ROUTINE MAINTENANCE

Page 10

ROUTINE MAINTENANCE

Viewing

Screen

11

5

23

0

Voltage

Selector

Input

Power

Fuse

Base

Securing

Screws

Rubber

Feet

Sub-Stage

Fuse

Securing Clip

Retaining Knobs

Graticule

Clean the viewing screen periodically with optical cloth.

GENERAL

MAINTENANCE

POINTS

If, after cleaning the

viewing screen, the

picture quality is

below standard,

remove and clean the 

graticule if fitted.

If the graticule

requires adjustment

after it has been

cleaned, see page 9.

NOTE

Ensure the Voltage Selector is

turned to the correct setting.

For Japan and some Far

Eastern markets the voltage

selector is marked 100 - 110V.

Changing the

Sub-Stage Fuse:

Remove the 4 rubber 

feet from the base

(push fit).

Remove the 5 base

securing screws.

Replace the fuse with 

an 800mA quick

blow type.

NOTE

When the base is

replaced, ensure

the heat slots line

up with the heatsink 

and substage bulb.

Summary of Contents for Lynx Stereo

Page 1: ...E N G I N E E R I N G Stereo ...

Page 2: ......

Page 3: ...research laboratory and biomedical uses Vision Engineering has manufacturing and distribution subsidiaries world wide as follows GREAT BRITAIN Manufacturing Base and Headquarters Vision Engineering Limited Tel 44 0 1483 223417 Send Road Fax 44 0 1483 223297 Send e mail 100721 1202 compuserve com WOKING Surrey GU23 7ER Commercial Vision Engineering Limited Tel 44 0 1483 248300 Monument House Fax 44...

Page 4: ...ion Engineering Limited Tel 33 0 1 64 46 90 82 Miniparc du Verger Fax 33 0 1 64 46 31 54 1 Rue de Terre Neuve e mail 100772 1206 compuserve com ZA Courtaboeuf 91967 Les Ulis Cedex France JAPAN Nippon Vision Engineering Tel 81 0 45 472 1004 No 6 Shinyokohama Hayama Building Fax 81 0 45 472 1177 1 28 8 Shinyokohama e mail info vision eng co jp Kohoku ku Yokohama shi Japan All other countries are cov...

Page 5: ... Stand Assembly 4 Column Attachment Assembly 5 Attaching Head 6 Objective Lens 6 Attaching 6 Point Ringlight 6 Attaching Spot Illuminator 7 Photographic Attachments 7 Zoom Multiplier 8 Mains Connection 8 Inserting Graticule 8 Operator Controls Main System Controls 9 Graticule Adjustment 9 Routine Maintenance General Maintenance Points 10 Sub Stage Lamp Changing 11 Illuminator Lamp Changing 11 ...

Page 6: ...Magnification Optical Information Lynx Magnification Table 12 Product Family Family Tree 13 Warranty ...

Page 7: ...pack Each pack has a check list on the outside of its contents PACKING CONTENTS Page 1 PACKING CONTENTS STAND PACK Column Stand Platform Adjustable Subject Platform HEAD PACK Substage Illuminator PLATFORM PACK OR Condenser Assembly with Diffuser ...

Page 8: ...5 ZOOM PACK Spot Lamp Assembly 6 Point Ringlight Illuminator Power Supply Objective Lenses Zoom Focus Assembly Anti glare Shield Spare Lamp ACCESSORIES PACKS Zoom Multiplier Photographic Adaptors Photo Arm Upright Horizontal Boom Bars Stage Boom Mount Bracket ...

Page 9: ... 1 left Allow room for the horizontal support bar to protrude behind the Lynx Feed the stand securing bolts up through the pressure cups and secure into the stand base see 2 left Attach the horizontal support bar to the vertical bar as shown in 3 above Slide the securing collar up and lock it into the desired position see 4 above HEAD TO TUBULAR SUPPORT ASSEMBLY Attach clamps to the horizontal pos...

Page 10: ...STAND ASSEMBLY Insert the Fan connect it and lock it in position with its securing screw see inset 1 Raise the column into the upright position and secure it with the four column securing screws Remove the Blanking Plate Remove the stage glass and lower the Stage onto the Stand Secure it with the 4 bolts supplied ...

Page 11: ...Put the condenser plate into position and fit the diffuser in either the base or subject platform as required Adjustable Subject Platform Slide the platform on to the column position it as required and secure it in position OR Slacken the securing clamp until the platform can be pushed on to the column Re tighten the clamp with the platform in the required position Zoom Focus Assembly Remove the C...

Page 12: ...levant slot in the Head Tighten the securing screw ATTACHING HEAD Securing Screws Objective Lens 6 Point Ring Light Beam Converger only for 1 5x or 2x lens Place the ringlight into position and tighten the securing screws Clip the Beam Converger only required if using a 1 5x or 2x objective lens into place and attach the fibre optic cable to the illuminator ATTACHING 6 POINT RINGLIGHT Objective Le...

Page 13: ...tach the appropriate Camera interface to the Photographic Attachment and tighten the securing screws NOTE Adapters for the Polaroid 35mm and CCTV Digital cameras are different The camera attaches to the interface PHOTOGRAPHIC ATTACHMENTS Objective Lens Spot Illuminator Connector Spot Illuminator Securing Screws Place the Spot Illuminator into position and tighten the securing screws Insert the ill...

Page 14: ...the securing screw Replace the Head on to the assembly and tighten the Head Securing NOTE Ensure the Voltage Selector is turned to the correct setting For Japan and some Far Eastern markets the voltage selector is marked 100 110V INSERTING GRATICULE Squeeze the securing clip at the base of the front cover and lift the cover off Loosen the appropriate retaining knob the graticule can be placed on e...

Page 15: ...e best clarity The focus will now be maintained throughout the Zoom range Squeeze the securing clip at the base of the front cover and lift the cover off To focus and centralize the graticule loosen the appropriate retaining knob and move the graticule up or down for focus and sideways to centralize Re tighten the retaining knob To adjust the graticule rotationally remove the rotation spigot from ...

Page 16: ...y is below standard remove and clean the graticule if fitted If the graticule requires adjustment after it has been cleaned see page 9 NOTE Ensure the Voltage Selector is turned to the correct setting For Japan and some Far Eastern markets the voltage selector is marked 100 110V Changing the Sub Stage Fuse Remove the 4 rubber feet from the base push fit Remove the 5 base securing screws Replace th...

Page 17: ...ENSURE THE ILLUMINATOR IS NOT HOT Press down the bulb fan assembly release button see 1 above Lift out the bulb fan assembly see 2 above Disconnect the lamp as shown in 3 above When relocating a lamp ensure it is fully pushed into the lamp holder SUB STAGE LAMP CHANGING ILLUMINATOR LAMP CHANGING NOTE The 250W Halogen lamp version 60 hours has the same lamp change procedure ...

Page 18: ...ringlight C 055 x0 5 x3 5 x20 x5 3 x30 x7 0 x40 175mm 7mm 46mm C 051 x0 7 x4 9 x28 x7 4 x42 x9 8 x56 127mm 5mm 33mm C 052 x1 0 x7 0 x40 x10 5 x60 x14 x80 85mm 3 5mm 24mm C 053 x1 5 x10 5 x60 x15 8 x90 x21 x120 45mm 2 5mm 16mm Requires converging lens Part No C 034 when used with 6 point ringlight C 054 x2 0 x14 x80 x21 x120 x28 x160 25mm 1 75mm 12mm Note Above figures without multipliers fitted To...

Page 19: ...x1 x2 25 Angle Adjuster Dust Cover C 103 Photographic Attachment C 069 Polaroid Camera C 061 Digital Camera CCTV Camera C 063 35mm Camera C 062 Adjustable Subject Platform C 011 C 040 C 041 C 152 Objective Lenses 0 3x C 050 0 5x C 055 0 7x C 051 1 0x C 052 1 5x C 053 2 0x C 054 Boom Mount C 145 Lynx Stereo FOR INSPECTION AND GENERAL MICROSCOPE APPLICATIONS E N G I N E E R I N G Platform Base for B...

Page 20: ......

Page 21: ...e caused by misuse neglect or carelessness or damage resulting from either improper servicing or modification by other than Vision Engineering approved service personnel Further this warranty does not cover any routine maintenance work on the product described in the instruction manual or any other minor maintenance work which is reasonably expected to be performed by the purchaser No responsibili...

Reviews: