Vision tools 08K0008A Technical Manual Download Page 6

 

General 

 

Technical Manual 

Version 1.5 

 

2.5 

Limitation of liability 

All information and statements in this manual are compiled in consideration of valid standards 
and regulations, as well as state of the art technological knowledge. 

 

The manufacturer accepts no liability for damages due to: 

  

 

Failure to observe this manual 

 

Inappropriate use 

 

Using non-trained personnel 

 

Undertaking unauthorized modifications 

 

Using impermissible replacement parts 

  

Additionally, the obligations, the General Terms and Conditions and delivery conditions of the 
manufacturer, and the statutory regulations valid at the time the contract was concluded will 
apply. 

  

2.6 

Copyright law 

Copyright law to this operating manual belongs to the company VisionTools Bildanalyse 
Systeme GmbH. This manual is intended only for the operator and the operator’s personnel. 
 

It includes regulations and information that may not be 

  

 

duplicated, 

 

distributed, or 

 

transmitted in any other manner, either in whole or in part. 

  

Duplicating the manual within a company for the purposes of training by the operator is 
excepted. Violations may have criminal consequences. 

  

2.7 

Guarantee and Liability 

Our General Terms and Conditions apply. Claims for a guarantee or for liability in case of 
personal injury or property damage are excluded if they are due to one or more of the 
following causes. 

 

  

 

Inappropriate use of the assembly 

 

Inappropriate installation, commissioning, operation, and maintenance of the device or 
system 

 

Failure to follow the information in the manual regarding transportation, storage, 
installation, commissioning, operation, limit values, maintenance of assemblies 

 

Unauthorized modifications to the assemblies 

 

Unauthorized modifications to the programmes 

 

Lack of monitoring of components subject to wear 

 

Catastrophic incidents due to foreign objects and force majeure 

 

Liability for subsequent damages is excluded 

  

Summary of Contents for 08K0008A

Page 1: ...Technical Manual MDL600 LED module light white diffuse Article No 08K0008A Version 1 5 ...

Page 2: ...se Systeme GmbH Heinrich Hertz Straße 7 68753 Waghäusel Germany Tel 49 7254 9351 0 Fax 49 7254 9351 200 www vision tools com info vision tools com Revision date April 2019 Version 1 5 Version change Attachment Technical data ...

Page 3: ...ility 4 2 6 Copyright law 4 2 7 Guarantee and Liability 4 3 Safety 5 3 1 Appropriate use 5 3 2 Foreseeable misuse 5 4 Technical Data 6 4 1 Dimensions mm 7 4 2 Pin Assignment 7 4 3 Settings 7 5 Commissioning 8 5 1 Initial operation 8 5 2 Return to service 8 5 3 Assembly 9 6 Maintenance and repair 10 6 1 Recommended Spare Parts 10 7 Product versions 10 8 Disposal 11 9 Notes 12 10 Attachment 13 10 1 ...

Page 4: ...nd instructions are to be carefully read before use The manual is a product component and must be kept accessible to the plant operator at all times 2 3 Documents enclosed Declaration of Conformity 2 4 Safety information In this manual icons acc to EN ISO 7010 are used to highlight correct text passages and relevant sections If the product is sold in a non EU country the warning symbols may need t...

Page 5: ...ions In accordance with DIN EN ISO 7010 General warning sign In accordance with DIN EN ISO 7010 Warning of electrical voltage In accordance with DIN EN ISO 7010 Warning of hot surface In accordance with DIN EN ISO 7010 Warning of oxidising substances In accordance with DIN EN ISO 7010 ...

Page 6: ... includes regulations and information that may not be duplicated distributed or transmitted in any other manner either in whole or in part Duplicating the manual within a company for the purposes of training by the operator is excepted Violations may have criminal consequences 2 7 Guarantee and Liability Our General Terms and Conditions apply Claims for a guarantee or for liability in case of pers...

Page 7: ...will bear sole responsibility for any damages that may result from such use the company VisionTools accepts no liability In case of changes or unauthorized modifications to the system any liability or guarantee from VisionTools Bildanalyse Systeme GmbH will cease to exist The electromagnetic behaviour of the system can be impaired by additions or changes of any kind Therefore make no changes or ad...

Page 8: ...A Power consumption 52 W Dimming external 0 10 V Dimming internal 0 100 Dimming fix 95 Trigger external 10 30 V Trigger Current approx 6 mA Perm ambient temperature 10 50 C Protection type IP40 Mean time between failures MTBF 100000 h Life span typ max 50000 h Luminous efficiency after 100h 98 Luminous efficiency after 50000h 95 Luminous efficiency after 100000h 90 Connection M12 Male Connector 4p...

Page 9: ...imensions mm X 620 4 2 Pin Assignment M12 Male Connector 4pin A Coded Pin Signal Colour of Conductor 1 24 VDC brown 2 white 3 0 V GND blue 4 EXT black 4 3 Settings Switch Position Setting MODE 1 internal dimming Poti 2 luminosity fix 3 external control ...

Page 10: ...rating voltage can be found in chapter Technical Data The MDL glows continuously because the slider is in the delivery status is at the second position see Settings 5 2 Return to service Specifically the following points should be noted The setting of the slide switch see Settings If necessary the surface of the MDL should be cleaned with a dry cloth to eliminate dust and other dirt ...

Page 11: ... the help of slot nuts In order to rotate an MDL with a flange clamping piece by 90 it is advisable to install a dedicated adapter plate between the MDL and the flange clamping piece Fig 1 Flange clamping piece FK18 Fig 2 Aluminium joint 8 40x40 Fig 3 Adapter plate 90 for FK18 NOTE It is recommended that for MDLs with sizes larger than 300mm either two flange clamping pieces or two aluminium joint...

Page 12: ...lange clamp FK 18 10A0008B Flange clamp FK 18 with elongated hole 08K0101A Adapter plate 90 for FK18 09E0003B Power cabel M12 4pos female connector 5m open end 09E0003C Power cabel M12 4pos female connector 10m open end 09E0003E Power cabel M12 4pos female connector 15m open end 09E0003D Power cabel M12 4pos female connector 20m open end 09E0003F Power cabel M12 4pos female connector 25m open end ...

Page 13: ...collection stations Your responsible administrative authority can give you more specific information on where authorized collection stations can be found NOTE Observe national regulations and internal operational solutions Dispose of the packaging of production materials including in the product cycle of the system appropriately Ensure appropriate separation and disposal ...

Page 14: ...Notes Technical Manual Version 1 5 12 9 Notes ...

Page 15: ...Attachment Technical Manual Version 1 5 13 10 Attachment 10 1 Declaration of conformity Konformitätserklaerung ...

Page 16: ......

Reviews: