Pin No.
Lens
DC
No.1 Pin
Damping -
No.2 Pin
D
No.3 Pin
Drive +
No.4 Pin
Drive -
Coaxial
5C-HFBT
Max. 100M
Network Server
(Decoder)
Network Server
(Encoder)
SDI-Monitor
Receiver
HD-Monitor
PC-DVR
4ch Digital Splitter
DVR
Stand Alone DVR
Optical Transmitter
Optical cable
Optical Receiver
40Km
Repea
ter
Coaxial
5C-HFBT
Max. 100M
LENS
DC
SHUTTER
D-WDR
WDR
ATW
AUTO
2DNR
CAM TITLE
LANGUAGE
SHARPNESS
FRAMERATE
FACTORY
3DNR
D-EFFECT
DEFECT
MONITOR
VIDEO.OUT
LSC
RESOLUTION RETURN
RETURN
LEVEL
MOTION
RS485
AWC→SET
COLOR
B/W
INDOOR
OUTDOOR
SMART NR
PRIVACY
PELCO-C
RETURN
VERSION
RETURN
MANUAL
BLC
HSBLC
OFF
AGC
DEFOG
SENS-UP BRIGHTNESS RETURN
MANUAL
EXPOSURE
BACKLIGHT
WHITE BAL
DAY&NIGHT
NR
SPECIAL
ADJUST
RESET
EXIT
SETUP
6. Installation
3. Solder the wires on the pin-connector (iris-jack) supplied with
the lens according to the pin configuration as shown in the
drawing.
4. Assemble the lens.
5. Connect the Auto Iris jack.
· Please assemble C-Mount adaptor.
· C-Mount adaptor is included in the package.
· Fix the lens by turning it clockwise.
6-3. When using a C-mount Lens
C-Mount ADAPTOR
6-4. When using a CS-mount Lens
· Take off the Protection cover.
· Take off the C-MOUNT adaptor.
· Assemble the CS-MOUNT lens by turning it clockwise.
- When used with an Auto Iris lens, please insert the iris jack into the
Iris socket which is located on the right side of the camera.
- Please set the lens mode by using OSD Switch on the back of the
camera depending on the type of selected lens.
CS-Mount Lens
6. Installation
- Insert the iris jack into the
iris socket.
LENS Connector
- Control the Lens (CS-Mount)
to focus the Lens.
CS-Mount
- Fix the CS-Mount using the
L-Wrench.
L-Wrench
*
Lens adjustment
Tele-Wide
Near-Far
6-5. Application of HD-SDI output
Impedance alliance in the system connection.Make sure to
connect the cable with the power off. Please locate the
impedance switch of each equipment as instructed.
Locate the switch to Hi-z position for the interim equipments
Locate the switch to 75 for the last equipment.
6. Installation
6-6. Power
12VDC camera
Please make sure to use a UL / CE
approved and 12VDC / 450mA
regulated power supply.
12VDC / 24VAC Dual Power camera
(Option)
Please make sure to use a UL / CE
approved and 12VDC / 450mA, 24VAC / 220mA regulated power
supply.
6-7. OSD Manual for functions control
6-8. Setting up the menu
Settings can be made using the OSD Switch located on the back of
the camera.
1. Press the button to access the
SETUP mode. The SETUP menu
is displayed on the monitor.
2. Please select any function you wish
to activate by using the UP / DOWN
selections. The cursor can be moved
up or down by using the UP / DOWN
selections. Position the cursor to point to the function you wish to
operate.
7. Dimension (mm)
66
64
138.8
8. Troubleshooting
Before asking for repairs, refer to the following table. If the problem
persists, please contact the dealer or your service center.
Problems
Troubleshooting
Nothing appears
on the screen.
· Please check that the power cord and line connection
between the camera and monitor are fixed properly.
· Please check that you have properly connected
VIDEO cable to the camera VIDEO output jack.
The dim image
on the screen.
· Is lens stained with dirt? Clean your lens with soft,clean
cloth.
· Set the monitor to proper condition.
· If the camera is exposed to too strong light, change
the camera position.
· Please check if the power supply is within the specification&
cables.(Due to the voltage drop with distance and gauges,
LED Will light poor)
· Adjust the contrast feature of the monitor.
· If there is an intermediate device,
set the 75Ω / Hi-Z properly.
(Please check the impedance)
· Please check if the power supply is regulated and is within
the standard requirement of the products.
· Please check the setting of White Balance setup.
· Please check if the camera is facing directly towards
sunlight or fluorescent light.
The dark image
on the screen.
The camera is
not working
properly, and
the body of the
camera is hot.
Color is not
correct.
The screen is
flickering.
RS-485
communication
fails.
· Please check the polarity between RS-485 Control
Port and RS-485 cable.
485 Control Board Connection Port
(+)CONNECTION TERMINAL(TRX+)
(-)CONNECTION TERMINAL(TRX-)
RS-485 Control Port
485+
485-
* RS-485 Communication establishment initial value.
· Please check if the RS-485 Communication establishment
initial value.
UART MODE
RET PKT
Item
Camera ID
BAUD RATE
Initial value
1
9600
8-NONE-1
ENABLE
· We recommend that you make ground connect between
camera and controller in order to maintain safety
communication control.
9. Specifications
Effective Pixels
Sensor Device
Sony 1/2.8 inch 2.1MP Exmor CMOS Sensor
1952(H) x 1116(V) 2.18 Megapixel
1944(H) x 1104(V) 2.14 Megapixel
Progressive Scan
More than 1100 TVL
More than 52dB
0.2 Lux (AGC On)
1/30s Default,(Long Exposure Mode, ~1Sec)
Total Pixels
Horizontal
S/N Ratio
Min. Illumination
Video Output Format
Digital Output
Day & Night
Serial Port
AV Output
Power Source
Operating Current
Operating Humidity
Weight ( Approx.)
Effective Pixels
Shutter Speed
Video Output
1920 x 1080 60p / 50p / 30p / 25P,
1280 x 720 60p / 50P / 30p / 25p (Mode Select)
1.485G/s, 2.97G/s HD-SDI Output, 1Port CVBS
1V p-p Composite. 75 Ohms
SDI Output
True Day & Night with ICR
Pelco-C support analog video only
CS Mount Lens Option
(2.8 ~ 12mm & 5 ~ 50mm 2Mega Lens)
DC IRIS / Manual Lens Mode Select
DC12V(24VAC / 12VDC Dual Power Option)
170mA
-10°C ~ 50°C
-20°C ~ 60°C
(Humidity : 0%RH ~ 90%RH)
1500g
Video Mode / D&N / AWB / AE / Privacy Mask /
Flickerless / Brightness / Sharpness /
Mirror & Flip / DSS / DNR, etc.
MODEL
2 Megapixel FULL HD Box Camera
Scanning System
Lens
Measurement (mm)
Lens Control
Operating Temperature
Storage Temperature
OSD
specifications are subject to change without prior notice.
*
66(W) x 64(V) x 138.8(L)
140623-1SFHD2