![Vision Fitness T9200 DELUXE Engineering Manual Download Page 2](http://html1.mh-extra.com/html/vision-fitness/t9200-deluxe/t9200-deluxe_engineering-manual_1031975002.webp)
ENGINEERING
GUIDES
Date of last revision: 2.06
TREADMILL.UPPERBDENG.DELUXE.REV1
2
ENGINEERING MODE
The user must hold down
“ELEVATION UP”
and
“SPEED DOWN”
for 5 seconds after powering up the treadmill to
enter the engineering menus. The P6 menu appears with the software version in the upper right window along with
the model number in the upper left window. Press
“STOP”
to exit P6. The user has 6 engineering modes to choose
from. The
“SPEED”
and
“ELEVATION”
keys scroll through the modes, while
“SELECT”
chooses the mode. HOLDING
the
“SELECT”
button saves information and the
“STOP”
button goes back to the previous screen. When in
Engineering modes 1-5, holding down the
“STOP”
button for 5 seconds will return you to the Engineering Mode
Selection Screen.
Display
Engineering Mode
Eng 1- Configure Mode
Edits variables stored in the NOVRAM. Speed and Incline variables
can be edited in this mode.
Eng 2- Display and Key Test
Tests displays and keyboard
Eng 3- Burn In Mode
Runs continuous program
Eng 4- Auto Calibration Mode
Calibrates both speed and elevation
Eng 5- Speed Sensor Test
Tests speed sensor functionality
Eng 6- Exit
Exit engineering mode
ENG1: EDIT VARIABLES MODE
The display shows the P address. To choose the P address press
“SELECT”
.
To clear P9 total time press and hold
“START”
for 3 seconds
To clear P10 total distance press and hold
“START”
for 3 seconds
T9200/T9250/T9450 VARIABLES
Address
Description
Default Value
Min.Value
MaxValue
P0
Minimum Speed Data
N/A
310
600
SP1
Speed Data 2
N/A
700
1100
P1
1/2 max Speed Data
N/A
1400
2100
SP2
Speed Data 4
N/A
2000
3000
P2
Max speed Data
N/A
3200
4500
P3
LED Brightness
3
0
9
P4
Minimum Elevation Data
N/A
30
300
P5
Max Elevation Data
N/A
650
900
P6
Model and Unit (Metric/US)
N/A
N/A
N/A
P7
Max Time
99
15
99
P8
Default Weight
150
80
400
P9
Accumulated Time
N/A
N/A
N/A
P10
Accumulated Distance
N/A
N/A
N/A
P11
Belt Thickness (depending on model)
16
44
P12
Roller Diameter
60
60
60
P13
Elevation motor
1
P14
Pause Time
5:00
:20
10:00
P15
Default Time
30
1
99
P16
Default Age
40
5
120
P17
Exit Mode (Exits Eng 1)
Deluxe Upper Board: Engineering Guide