1624R, 2525 and 2550 Series 5 Installation
33
© 2019 Vision Engraving Systems
2.7
Series 5 Controller Connections
On the rear of the Vision Series 5 controller, there are 13 connection ports. Plug in all of the cables
unless noted below.
1. The Aux Table plug connects to a 15 pin connector on the Vision 2525 and 2550.
NOTE:
This is not
used with the 1624R.
2. The Table plug connects to a 25 pin connector on the Vision 1624R, 2525 and 2550.
3. The Rotary plug connects to a 9 pin connector on the Vision Rotary attachment.
NOTE:
This is not
used unless a rotary attachment or configured with the machine.
4. The 90V Spindle plug connects a 4 pin round connector that comes from the Vision 1624R, 2525 and
2550.
5. The Vacuum plug connects to a 2 pin round connector that comes from an optional vacuum chip
removal system. If your machine is equipped with the optional Vacuum Chip Removal System, a
remote On/Off cable is connected to the controller to automatically turn the vacuum pump on and off
when the job is being run.
NOTE:
This will not be used if a vacuum chip removal system is not
configured with the machine.
6. The Pump/Mist plug connects to a misting system or water pump.
NOTE:
This is not used unless a
misting system or water pump is configured with the machine.
7. The Computer plug connects to the Ethernet port on the computer. This is typically plugged into the
USB to Ethernet adapter supplied with the machine.
8. The Pendant network plug connects to the back of the touch screen LCD pendant.
9. The 4 pin Pendant plug connects to the back of the touch screen LCD pendant.
10. The Mod Bus plug connects to the 3 hp router spindle power inverter.
NOTE:
This is only used if the
3 hp router motor is configured with the machine.
11. The power input plug connects to either the power source.
IMPORTANT:
Only use the 110 volt AC
or 220 volt AC power source that is displayed on the yellow label. Using the incorrect input power
can cause serious damage to the machine.
12. The Analog plug is used to control optional spindles such as a 50,000 RPM spindle.
NOTE:
This is
not used unless an optional spindle is configured with the machine.
13. The Aux plug is an expansion port that can be used for new products at a later date.
NOTE:
This is
not currently used.
Summary of Contents for 1624R
Page 1: ...2019 Vision Engraving Systems Vision 1624R 2525 and 2550 Series 5 User Guide Revised 7 3 2019...
Page 20: ...Vision Series 5 Controller User Manual 20 2019 Vision Engraving Systems 1624R Diagrams...
Page 21: ...1624R 2525 and 2550 Series 5 Installation 21 2019 Vision Engraving Systems...
Page 22: ...Vision Series 5 Controller User Manual 22 2019 Vision Engraving Systems...
Page 26: ...Vision Series 5 Controller User Manual 26 2019 Vision Engraving Systems 2525 2550 Diagrams...
Page 27: ...1624R 2525 and 2550 Series 5 Installation 27 2019 Vision Engraving Systems...
Page 37: ...1624R 2525 and 2550 Series 5 Installation 37 2019 Vision Engraving Systems...
Page 54: ...Vision Series 5 Controller User Manual 54 2019 Vision Engraving Systems...
Page 58: ...Vision Series 5 Controller User Manual 58 2019 Vision Engraving Systems...
Page 128: ...Vision Series 5 Controller User Manual 128 2019 Vision Engraving Systems...
Page 130: ...Vision Series 5 Controller User Manual 130 2019 Vision Engraving Systems...
Page 131: ......