Vision Engineering Swift PRO Cam User Manual Download Page 4

UNPACKING

1

2

3

Copyright

Copyright © 2017 Vision Engineering Ltd., The Freeman 
Building, Galileo Drive, Send, Woking, Surrey GU23 7ER, 

UK All Rights Reserved.

Mantis® (1532468), Lynx® (3672061) and Dynascope® 

(915579) are registered trademarks of Vision Engineering 
Ltd. The use of our trademarks is strictly controlled and 
monitored and any unauthorised use is forbidden.

Copyright in this document is owned by Vision 
Engineering Ltd. Any person is hereby authorised to 

view, copy, print and distribute this document subject to 

the following conditions:

 

ƒ

The document may be used for informational purposes 
only

 

ƒ

The document may be used for non-commercial 
purposes only

 

ƒ

Any copy of this document or portion thereof must 
include this copyright notice

Revision 1.0, published June 2017 by:

Vision Engineering Ltd. 

The Freeman Building, Galileo Drive, Send,

 

Woking, Surrey, GU23 7ER, UK

 

www.visioneng.com

Disclaimer

This document is provided “as is” without any warranty 

of  any  kind,  either  express  or  implied,  statutory  or 
otherwise; without limiting the foregoing, the warranties 
of satisfactory quality, fitness for a particular purpose or 

non-infringement are expressly excluded and under no 
circumstances will Vision Engineering Ltd. be liable for 

direct or indirect loss or damage of any kind, including 
loss of profit, revenue, goodwill or anticipated savings. 

All such warranties are hereby excluded to the fullest 
extent permitted by law.

We have compiled the texts and illustrations as accurately 

as possible. However, Vision Engineering Ltd. will not be 

responsible for the accuracy of the information contained 

in  this  document,  which  is  used  at  your  own  risk  and 

should not be relied upon. The information included in 
this manual may be changed without prior notice.

Summary of Contents for Swift PRO Cam

Page 1: ...ft PRO Cam 9 9 Swift PRO Elite User Guide Vision Engineering Ltd has been certified for the quality management system ISO 9001 2015 FM 557119 Est 1958 www visioneng com Swift PRO series of optical and...

Page 2: ......

Page 3: ...safety A dust cover is supplied with your system Turn off your system and ensure it has cooled down before using the dust cover Illumination safety Do not look directly at the illuminated LED s This...

Page 4: ...ision Engineering Ltd The Freeman Building Galileo Drive Send Woking Surrey GU23 7ER UK www visioneng com Disclaimer This document is provided as is without any warranty of any kind either express or...

Page 5: ...C system connection 6 QC 3000 connection 6 Stage alignment video systems only 7 Securing the stage 150mm x 100mm 200mm x 100mm 7 Head attachment 8 Fitting the stage glass 8 Stage glass levelling 9 Ant...

Page 6: ...Height adjustment 14 Encoder Resolution 14 Video Camera 14 Optics Swift PRO Duo and Elite 14 Illumination 14 PSU fuse ratings 14 Dimensions 14 Swift PRO Duo and Elite 14 Swift PRO Cam 14 Service calib...

Page 7: ...com support 1 System equipment Stand objectives Stand Lens mount Lens options Illuminator options Toolkit Anti glare shield Z Axis upgrade kit optional Swift PRO Cam Stage 150mm x 100mm manual stage...

Page 8: ...System equipment www visioneng com support 2 Head QC 3000 Controller PC Monitor Keyboard and mouse...

Page 9: ...of your system It is highly recommended that you refit the transit protection whenever you transport your system Attaching the lens mount Insert the lens mount u up into the focus assembly v and secu...

Page 10: ...g the episcopic illuminator EPI Locate the cone u over the EPI v and secure it with the grub screw w Locate the EPI into the focus assembly x and secure it with the grub screw y Connecting the EPI Ins...

Page 11: ...the underside of the stage x are clean and free of any debris Loosely fit the stage bolts y in position B1 B2 and B3 also in diagram v to a light finger tight tension If this is a video system do not...

Page 12: ...gaged fully and secured WARNING To comply with safety regulations easy access to the mains socket must be maintained Y Axis Z Axis if fitted From camera USB to controller USB to controller X Axis Main...

Page 13: ...n be removed the relevant stage securing procedure should be carried out Securing the stage 150mm x 100mm 200mm x 100mm With the stage assembled see page 5 and aligned see above secure the stage as fo...

Page 14: ...rn the head to align the head crosshair with the alignment plate see inset Tighten the securing screw Remove the alignment plate If you need to remove the stage for any reason re attach the alignment...

Page 15: ...the front right hand corner into view Use the relevant adjustable glass support to bring the surface of the glass into sharp focus Repeat for the remaining 2 corners Repeat the above steps if necessar...

Page 16: ...Y axis control X axis control Coarse focus control Fine focus control On off switch Substage light dimmer Episcopic light dimmer Ringlight dimmer Iris control All desktop control systems configured b...

Page 17: ...pply Maximum relative humidity of 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C This system is an accurate industrial gauging instrument To achieve the optimum acc...

Page 18: ...e the graticules v 2 off into position and secure them with the lock nuts and grubscrews w 2 per graticule and the retaining bolts x To focus and centralize each graticule loosen the appropriate retai...

Page 19: ...cedure should only be carried out by authorised service personnel Please contact your local Vision Engineering branch for assistance Episcopic LED replacement Remove the episcopic assembly u from the...

Page 20: ...ideo camera Optics Swift PRO Duo and Elite Patented twin pupil monoscopic infinity corrected optical system with pre centred crossline graticule to both eyes Option of custom designed graticule pre ce...

Page 21: ...ervice calibration record Serial numbers System serial number Stage serial number PSU serial number Service information Service type Comments Date of service Date of next service Company Signature Sys...

Page 22: ......

Page 23: ...in transit damage caused by misuse neglect or carelessness or damage resulting from either improper servicing or modification by other than Vision Engineering approved service personnel Further this...

Page 24: ...sioneng com Vision Engineering Ltd Italia Via G Paisiello 106 20092 Cinisello Balsamo MI Italia Tel 39 02 6129 3518 Email info visioneng it Vision Engineering South East Asia P 03A 20 Impian Meridian...

Reviews: