background image

DL30x60-IR850/UDC/-a

Operation

7 OPERATION

CAUTION

Physiological effects by flashing lights

Working under flashing lights can cause effects such as

headache, nausea, or epileptic seizures.

Avoid exposure to certain kinds of flashing lights or

stroboscopes.

Wear protective goggles.

If you have a known history of epilepsy, do not work or stay

in areas where there are flashing lights or stroboscopes.

CAUTION

Impairment of eye-sight due to dazzling.

Do not look during operation directly in LED lighting or whose

rays.

Wear protective goggles.

In the event of dazzling, allow sufficient time for the eyesight

to adapt to the ambient illumination before commencing

other activities.

CAUTION

Danger of burns due to hot surfaces.

The housing of the device can reach temperatures

exceeding 55 °C during operation.

Do not touch the device.

Allow the surface to cool down before touching.

28

999.995.533.10-en-1.2

© Vision & Control GmbH 2019

Summary of Contents for DL30x60-IR850/UDC/-a

Page 1: ...for Use DL30x60 IR850 UDC a LED area light diffuse illumination Luminous colour Infrared 850 nm Instructions for Use DL30x60 IR850 UDC a LED area light diffuse illumination Luminous colour Infrared 85...

Page 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Page 3: ...Identification Designation Description DL LED area light diffuse illumination 30x60 Dimensions light emitting surface 60 mm x 30 mm IR850 Wavelength Infrared 850 nm UDC User Defined Controller Flasha...

Page 4: ...2 Notices on the device 15 5 Technical Data 16 5 1 General Parameters 16 5 2 Electrical Parameters 18 5 3 Photometric Parameters 20 5 4 Conditions for Operation Storage and Transport 21 5 5 Technical...

Page 5: ...DL30x60 IR850 UDC a Table of Contents 8 1 Maintenance 31 8 2 Service 32 9 Disposal 33 10 EU Declaration of Conformity 34 Vision Control GmbH 2019 999 995 533 10 en 1 2 5...

Page 6: ...DL30x60 IR850 UDC a 6 999 995 533 10 en 1 2 Vision Control GmbH 2019...

Page 7: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potent...

Page 8: ...ons of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Page 9: ...ual and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the main...

Page 10: ...es of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with mediu...

Page 11: ...ice and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric s...

Page 12: ...in straight 2 m 1 11 612 Cable with M8 socket 4 pin straight 3 m 1 11 613 Cable with M8 socket 4 pin straight 5 m Connection cable with 4 pin M8 socket and open cable end with ferrules 4 x 0 5 PUR IP6...

Page 13: ...DLC3005 1 30 212 Connection cable DLC operating voltage supply Designation Description Order no Connection cable DLC3005 1 m 1 30 222 Connection cable DLC3005 2 m Connection cable with 2 pin PTSM plu...

Page 14: ...4 DEVICE DESCRIPTION 4 1 Device Views 2 3 1 4 Image 1 Device view 1 Light emitting surface 2 Casing 3 Connection cable with 4 pin M8 connector 4 2 x M3 mounting hole depth 6 mm on each side 14 999 995...

Page 15: ...Following instructions are provided on the device Type plate Vision Control 98527 Suhl Germany Type XXXXXXXXXXX No XXXXXXXX 1 3 2 Image 2 Type plate 1 Device designation 2 Manufacturer information 3...

Page 16: ...anodised Optical material PMMA Housing dimensions 65 mm x 35 mm x 23 mm without connector Dimensions light emitting surface 60 mm x 30 mm Weight 92 g Degree of protection IP IP 50 Safety class Class I...

Page 17: ...ending radius cable fixed at least 5 x cable diameter Bending radius cable moved at least 10 x cable diameter Bending cycles at least 4 million Robot suitable no Connector Parameter Characteristic Con...

Page 18: ...meter Min Max Continuous operation LED current ILED 0 4 A 1 Forward voltage ULED at ILED Max 5 7 V 6 9 V Power consumption Ptot 2 4 W 1 Flash mode Pulse mode LED current ILED 8 0 A 2 Forward voltage U...

Page 19: ...F Duty Cycle Power on time Power off time Image 3 Pulse load ADVICE To take advantages of the vicolux smart light technology enter the following Light Code in the user interface of your smart light co...

Page 20: ...ral bandwidth 1 30 nm Continuous operation Radiance 100 W m sr Flash mode Pulse mode Radiance 1 575 W m sr 1 The wavelengths stated are maintained as from an LED current of 0 04 A Spectral Emission Re...

Page 21: ...original packaging For accessories connected devices and components observe the specific information in the associated instructions for use Ambient Conditions Operation Storage Transport Temperature 0...

Page 22: ...ical Drawings light emitting surface M8 connector 2 x M3 depth 6 on both sides 5 150 65 60 30 35 25 23 7 75 5 7 75 20 25 2 x M3 depth 6 on both sides Image 5 Technical drawings dimensions in mm 22 999...

Page 23: ...together with the device out of the carton 2 Fold out the tucked in sides on the bottom of the cardboard Loosening the film and forming an insertion pocket 3 Remove the device out of the insertion poc...

Page 24: ...de energised state To mount the device tapped holes are located at the sides 2 2 1 1 1 2 x M3 tapped hole on both sides Maximum screw in depth 6 mm Distance between the tapped holes 25 mm 2 2 x M3 tap...

Page 25: ...light lighting controller is not hot plug capable Connect or disconnect lights during operation may destroy the lights Connect or disconnect lights only if the lighting controller is in the off and d...

Page 26: ...assignment 1 3 2 4 Image 6 M8 male plug 4 pin Connection diagram 3 BU 4 BK 1 BN WH 2 ILED ILED NC NC Pin Core colour Signal Description 1 BN brown ILED LED anode positive current input 2 WH white NC D...

Page 27: ...light lighting controllers When using a vicolux smart light lighting controller the light is configured via the user interface DLC Server Control Center Refer to the Instructions of Use DLC Server Co...

Page 28: ...are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly in LED lighting or whose rays Wear protective goggles In the event of dazzling...

Page 29: ...olux smart light lighting controller NOTICE Damage caused by incorrect connecting and disconnecting The vicolux smart light lighting controller is not hot plug capable Connect or disconnect lights dur...

Page 30: ...r continuous operation apply a constant current ILED to the lighting Flash operation For pulse or flash operation apply current pulses ILED to the lighting Observe the specified parameters see Electri...

Page 31: ...tside with a damp cloth Remove excessive dirt with an approved anodised aluminium cleaner Refer to the instructions of the cleaner The connectors must be clean and dry before the device is connected a...

Page 32: ...glad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective devic...

Page 33: ...separately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Page 34: ...rial environments DIN EN 61000 6 4 2011 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and measur...

Page 35: ...DL30x60 IR850 UDC a Vision Control GmbH 2019 999 995 533 10 en 1 2 35...

Page 36: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...