pictor M1817
Commissioning
© Vision & Control GmbH 2014
999.994.528.10-en-1.4
32
7.2 Mounting
DAMAGE OF PROPERTY
Cable damaged by a bending radius that is too small and the lack of a
strain relief clamp.
•
Comply with the specified minimum bending radius.
•
Cables must generally be mounted with a strain relief clamp.
•
Use cables corresponding to the specification (see data sheet).
Mounting of cables
When mounting the cable to the device, hold the device and plug the cable into
the connector.
Mounting the device
To install the device, a mounting block with two tapped holes M6 and a 1-32
UN 2A thread is located at the bottom.
Distance between the tapped holes
25 mm
Maximum screwed-in depth
7 mm
Maximum tightening torque
10 Nm
Table 9: Properties of the tapped holes
Summary of Contents for 4-20-327
Page 62: ......