6.3 Mounting the accessories

Mount the Lens Holder

a

a

1.)

2.) 3.)

1. Loosen the M5 hexagon nuts (a) on the lens holder.
2. Slide the lens holder to the desired location on the lighting.
3. Tighten the M5 hexagon nuts alternately hand-tight in small steps.

Mount the Filter adapter (slip-on adapter)

1.)

2.) 3.)

a

a

a

1. Loosen the M3 threaded pins (a) of the slip-on adapter.
2. Attach the slip-on adapter on the lighting.
3. Tighten the M3 thread pins alternately hand-tight in small steps.
Then screw the filter into the internal thread of the slip-on adapter.

22

999.995.417.10-en-1.1

© Vision & Control GmbH 2021

Summary of Contents for 1-33-239

Page 1: ...ONTROL Instructions for Use TZB10 IR850 P SL Telecentric Lights Luminous colour Infrared 850 nm Instructions for Use TZB10 IR850 P SL Telecentric Lights Luminous colour Infrared 850 nm 999 995 417 10...

Page 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Page 3: ...33 239 Product Identification Designation Description TZB Telecentric Lights 10 Luminous field diameter in mm IR850 Luminous colour Infrared 850 nm P Power LED SL SL vicolux smart light Flashable LED...

Page 4: ...15 5 Technical Data 16 5 1 General Parameters 16 5 2 Electrical Parameters 17 5 3 Photometric Parameters 18 5 4 Conditions for Operation Storage and Transport 19 5 5 Technical Drawings 20 6 Commissio...

Page 5: ...uture reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potenti...

Page 6: ...s of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1 3...

Page 7: ...l and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the mainte...

Page 8: ...s of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medium...

Page 9: ...safety instructions are referred to separately at the relevant points in this manual DANGER IR radiation emitted from this product IR radiation is not visible to humans During operation do not stare i...

Page 10: ...1 x Instructions for Use TZB10 IR850 P SL 1 x Safety label optical radiation 1 x 3 2 Accessories Lens holder Designation Description Order no Lens Holder d35 5 Holder for telecentric lenses and lighti...

Page 11: ...oller Designation Description Order no DLC 3005 Digital lighting controller wall mounting continuous operation 4 8 A flash operation 18 A 1 30 202 DLC 3005 R Digital lighting controller rail mounting...

Page 12: ...cable Type A Micro B 1 m included in scope of delivery DLC to connect the DLC3005 to a PC USB 2 0 Type A plug to micro B plug 1 30 207 Connection cable M8 4 pin straight plug 4A 60V Designation Descr...

Page 13: ...onnection cable with 4 pin M8 socket and open cable end with wire end ferrules 4 x 0 5 mm 5A 30V PUR IP67 straight plug 1 11 614 Extension cable M8 4 pin 5A 30V Designation Description Order no Extens...

Page 14: ...1 Device Views 7 2 3 4 6 6 6 5 1 Image 1 Device view 1 Casing 2 Light emitting surface 3 Identification plate 4 Warning notice 5 Note screw in depth 6 Mounting surface with mounting holes 7 Connector...

Page 15: ...ed on the device Warning notice Image 2 Notice optische Strahlung Type plate Type TZB10 XXXX P SL SN XXXXXXXX 1 2 Image 3 Type plate 1 Device designation 2 Serial number Notice Screw in depth screw in...

Page 16: ...e of protection IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Continuous operation Risk group 1 Flash mode Risk group 1 Overheat protection TMAX 1 80 C 1 The LED o...

Page 17: ...ters The LED overheating protection is not guaranteed Parameter Min Nom 1 Max Continuous operation LED current ILED 0 8 A Forward voltage ULED at ILED Max 3 0 V Power consumption Ptot 2 4 W Flash mode...

Page 18: ...vergence angle 2 1 6 Luminous field diameter 1 11 5 mm Luminous efficacy of radiation 0 1 lm W Continuous operation Irradiance 1 107 W m2 Illuminance 1 Radiance 2 38 4 kW m2sr Luminance 2 Flash mode I...

Page 19: ...rve the specified ambient conditions when transporting and storing the device For accessories connected devices and components observe the specific information in the associated instructions for use A...

Page 20: ...tra e 16 98527 Suhl 1 2 3 4 5 1 2 3 4 5 A A B B C C D D M8 connector TZB10 XXXX P 24V TZB10 XXXX HP 24V l i g h t e m i t t i n g s u r f a c e 1 1 5 3 5 5 2 x M4 depth 6 15 6 15 23 10 58 13 23 33 7 I...

Page 21: ...the tucked in sides on the bottom of the cardboard The film loosens and forms an insertion pocket 3 Remove the device out of the insertion pocket 4 Dispose the packing material 6 2 Mounting the Device...

Page 22: ...Tighten the M5 hexagon nuts alternately hand tight in small steps Mount the Filter adapter slip on adapter 1 2 3 a a a 1 Loosen the M3 threaded pins a of the slip on adapter 2 Attach the slip on adap...

Page 23: ...Label Due to the individual assembly and installation options the device is supplied with the safety label optical radiation After completing all assembly work attach the safety label to the device so...

Page 24: ...connecting The vicolux smart light lighting controller is not hot plug capable Connect or disconnect lights during operation may destroy the lights Connect or disconnect lights only if the lighting co...

Page 25: ...ht vicolux Image 9 Connection diagram vicolux smart light Pin Core colour Signal Description 1 BN brown ILED LED anode positive current input 2 1 WH white BD Data Channel for vicolux smart light modul...

Page 26: ...void exposure to certain kinds of flashing lights or stroboscopes Wear protective goggles If you have a known history of epilepsy do not work or stay in areas where there are flashing lights or strobo...

Page 27: ...olux smart light lighting controller is not hot plug capable Connect or disconnect lights during operation may destroy the lights Connect or disconnect lights only if the lighting controller is in the...

Page 28: ...eaning the optical surfaces NOTICE Follow the specified cleaning sequence Never use dry cloths for cleaning This allows dust and other contaminants to be rubbed into the lens surface thereby damaging...

Page 29: ...ad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device...

Page 30: ...parately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done i...

Page 31: ...l environments DIN EN IEC 61000 6 4 2020 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and measu...

Page 32: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...

Reviews: