VisioFocus mini 06700 Operating Instructions Manual Download Page 16

15

Keep dry

Crossed-out wheeled bin (WEEE and batteries) 

Instructions for disposal

: this product contains electrical and 

electronic components and batteries that may contain materials 

which, if disposed with general waste, could be damaging to the en-

vironment. Residents of the European Union must follow specific dis-

posal or recycling instructions for this product. Residents outside the 

European Union must dispose or recycle this product in accordance 

with local laws or regulations that apply.

WARRANTY

Tecnimed s.r.l. guarantees this product against any lack of conformity for 24 

months as of the date of purchase (indicated on the cash register receipt or other 

fiscal document). Follow the instructions given by your Dealer for the technical 

service procedures. 

This warranty does not cover the batteries and any damage caused by defective 

or run down batteries or damage to the casing due to carelessness or improper 

use. The warranty is also voided if:

- the product is tampered with, damaged or used improperly;

- the label on the back bearing the serial number is removed, damaged or rende-

red illegible;

- the product is opened or repaired by unauthorized personnel; 

- the product has been damaged due to non-compliance with the instructions 

given in this manual.

If Technical Service is required, contact the Manufacturer or your Dealer. 

In case the Product was purchased through an Online-store, warranty service 

can only be provided through the Internet Seller, where the product was pur-

chased. In case of any lack of conformity, the product will be either repaired or 

replaced, as decided by the Manufacturer or Dealer, at their sole discretion. Any 

repaired or replaced product does not extend the original warranty beyond the 

period of 2 years from original date of purchase.

If, after technical evaluation, the Product is found not to be covered by the terms 

and conditions of this Warranty (because no lack of conformity is found), Tecni-

med reserves the right to charge a handling fee for technical check and delivery.

Under no circumstance may Tecnimed be held responsible for damages related 

to the improper use of the product or for costs exceeding the original price of the 

product.

Summary of Contents for mini 06700

Page 1: ...Operating instructions EN Rev 9 6700 2021 09 Read these instructions carefully before using the thermometer CAUTION read the warnings 06700...

Page 2: ...e 3 Sensor at the bottom of the waveguide 4 Aiming light 5 FACE button LED 6 FACE button for forehead temperature readings 7 HOME button LED 8 HOME button for other readings 9 MEMORY button 10 MEM but...

Page 3: ...0 and 40 0 C 60 8 and 104 0 F It can also work if room temperature is in the ranges 10 0 15 9 C 50 0 60 7 F and 40 1 45 0 C 104 1 113 0 F but accuracy is not gua ranteed see also par 13 3 If the devi...

Page 4: ...sor and the most delicate part of the thermometer It must be kept clean and intact Any damage dust or dirt will alter the temperature reading 12 Do not handle the thermometer for longer than strictly...

Page 5: ...h the projection Please note that that body temperature varies among individuals moreo ver individual temperature varies according to the measurement s site and throughout the day also in response to...

Page 6: ...ld it down The two aiming lights and the light of the face button turn on and you will begin to see the temperature reading projected onto the forehead between or overlaid to two dots While keeping th...

Page 7: ...e lights are harmless Precision is not guaranteed but such reading can be considered a valid approximation of one s body temperature In adults such reading is also indicated when one has oil or make u...

Page 8: ...the Mem button the projection will show the letter A Ambient alternating with the ambient temperature value 6 MEMORY FUNCTION The Mem button lets you call up the last 9 temperature readings Proceed a...

Page 9: ...let you take a measurement as the result would not be correct On the contrary it will activate an Automatic Quick Calibration System AQCS Now you have two possibilities 1 Wait about 5 minutes without...

Page 10: ...bilize for 20 minutes before taking a temperature reading or run a manual quick calibration MQCS par 8 Remove the batteries if you do not expect to use the thermometer for a long time 10 CLEANING CLEA...

Page 11: ...lash before moving the thermometer make certain that there are no mobile or cordless telephones in the vicinity DESCRIPTION the projection shows CAL and or a count down in seconds PROBLEM the thermome...

Page 12: ...MEANING ATTENTION The temperature is 40 0 C 104 0 F or more DESCRIPTION the projection reads Hi 2 PROBLEM reading with face button the temperature detected exceeds the limit for operation with this bu...

Page 13: ...ture reading is too high make certain that the conditions outlined in the warnings have been met par 2 7 The thermometer appears blocked or does not revert to stand by after being idle for 20 seconds...

Page 14: ...or Hi 4 respectively Ambient temperature shown when in stand by Measurement range 5 0 45 0 C 41 0 113 0 F Accuracy 1 0 C 1 8 F 13 2 General specifications Power supply 2 AAA LR03 alkaline batteries 1...

Page 15: ...standards EN 60601 1 EN 60601 1 2 EN 60601 1 6 EN 60601 1 11 EN 62366 EN 62471 EN 62304 EN 80601 2 56 ASTM E 1965 98 Full responsibility for the conformance of this product to the standards is assume...

Page 16: ...ged or used improperly the label on the back bearing the serial number is removed damaged or rende red illegible the product is opened or repaired by unauthorized personnel the product has been damage...

Page 17: ...66 US 7 651 266B2 US 8 128 280 US 8 821 010 EP 1 283 983 EP 1 886 106 EP 2577242 B1 KR 10 1898897 CN 103026192B Other international patents pending Manufactured in Italy by TECNIMED srl P le Cocchi 12...

Reviews: