Vishay TSSP57038H Manual Download Page 8

TSSP57038H

www.vishay.com

Vishay Semiconductors

  

 

Rev. 1.3, 10-Apr-2019

8

Document Number: 82798

THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT

ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT 

www.vishay.com/doc?91000

LABEL

Standard bar code labels for finished goods

The standard bar code labels are product labels and used

 

for identification of goods. The finished goods are packed in

 

final packing area. The standard packing units are labeled

 

with standard bar code labels before transported as finished

 

goods to warehouses. The labels are on each packing unit 
and contain Vishay Semiconductor GmbH specific data.

DRY PACKING

The reel is packed in an anti-humidity bag to protect the

 

devices from absorbing moisture during transportation and

 

storage.

FINAL PACKING

The sealed reel is packed into a cardboard box.

 

 

 

RECOMMENDED METHOD OF STORAGE

Dry box storage is recommended as soon as the aluminum

 

bag has been opened to prevent moisture absorption. The

 

following conditions should be observed, if dry boxes are

 

not available:

• Storage temperature 10 °C to 30 °C

• Storage humidity 

 60 % RH max.

After more than 168 h under these conditions moisture

 

content will be too high for reflow soldering.

In case of moisture absorption, the devices will recover to

 

the former condition by drying under the following condition:

192 h at 40 °C + 5 °C / - 0 °C and < 5 % RH (dry air / 
nitrogen) or 

 

96 h at 60 °C + 5 °C and < 5 % RH for all device containers

 

or 

 

24 h at 125 °C + 5 °C not suitable for reel or tubes.

An EIA JEDEC

®

 standard J-STD-020 level 3 label is included

 

on all dry bags.

VISHAY SEMICONDUCTOR GmbH STANDARD BAR CODE PRODUCT LABEL

 (finished goods)

PLAIN WRITING

ABBREVIATION

LENGTH

Item-description

-

18

Item-n

u

mber

INO

8

Selection-code

SEL

3

LOT-/serial-n

u

mber

BATCH

10

Data-code

COD

3 (YWW)

Plant-code

PTC

2

Q

u

antity

QTY

8

Accepted by

ACC

-

Packed by

PCK

-

Mixed code indicator

MIXED CODE

-

Origin

Company logo

Long bar code top

Type

Length

Item-n

u

mber

N

8

Plant-code

N

2

Se

qu

ence-n

u

mber

X

3

Q

u

antity

N

8

Total length

-

21

Short bar code bottom

Type

Length

Selection-code

X

3

Data-code

N

3

Batch-n

u

mber

X

10

Filter

-

1

Total length

-

17

Aluminum bag

Label

Reel

15973

Summary of Contents for TSSP57038H

Page 1: ... Up to 2 m for presence sensing Uses modulated bursts at 38 kHz PIN diode and sensor IC in one package Low supply current External metal shield Visible light is suppressed by IR filter Insensitive to supply voltage ripple and noise Supply voltage 2 5 V to 5 5 V Material categorization for definitions of compliance please see www vishay com doc 99912 DESCRIPTION The TSSP57038H is a compact infrared...

Page 2: ...velope signal Out to μC ABSOLUTE MAXIMUM RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT Supply voltage VS 0 3 to 6 V Supply current IS 5 mA Output voltage VO 0 3 to VS 0 3 V Output current IO 5 mA Junction temperature Tj 100 C Storage temperature range Tstg 25 to 85 C Operating temperature range Tamb 25 to 85 C Power consumption Tamb 85 C Ptot 10 mW ELECTRICAL AND OPTICAL CHARACTERISTICS Tamb ...

Page 3: ... Signal IR diode TSAL6200 IF 0 4 A 30 pulses f f0 t 10 ms Output Signal td 1 tpo 2 1 7 f0 td 15 f0 2 tpi 5 f0 tpo tpi 6 f0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 1 10 100 1000 10 000 100 000 t po Output Pulse Width ms Ee Irradiance mW m2 Output pulse width Input burst length λ 950 nm optical test signal Fig 1 Ee t VO VOH VOL t 600 µs 600 µs t 60 ms ton toff 94 8134 Optical Test Signal Output Sign...

Page 4: ...benefit from the lower gain of these sensors because they are less sensitive to stray signal from the emitter simplifying the mechanical design Example for a sensor hardware There should be no common window in front of the emitter and detector in order to avoid crosstalk via guided light through the window 0 2 0 4 0 6 0 8 1 0 1 2 1 4 1 6 1 8 2 0 2 3 4 5 E e min Sensitivity mW m 2 VS Supply Voltage...

Page 5: ... GND GND GND 0 75 0 05 4 x 0 75 3 0 35 0 05 8 x 1 5 3 0 3 0 3 0 3 0 7 1 7 3 25 Proposed pad layout from component side dim for reference only 4 3 4 3 0 35 0 8 2 75 4 x 0 75 3 3 x technical drawings according to DIN specifications All dimensions in mm Not indicated tolerances 0 1 Drawing No 6 550 5316 01 4 Issue 2 12 02 14 3 x 0 45 1 2 1 2 3 4 5 8 7 6 Marking area 0 4 Pin 1 identification 0 475 All...

Page 6: ... there is a temperature difference between the component and the circuit board it should be verified that the temperature of the device is accurately being measured Handling after reflow should be done only after the work surface has been cooled off Manual Soldering Use a soldering iron of 25 W or less Adjust the temperature of the soldering iron below 300 C Finish soldering within 3 s Handle prod...

Page 7: ...IONS in millimeters Reel size Y TT1 Ø 180 2 1500 pcs Unreel direction X Tape position coming out from reel 2 0 5 Ø 13 0 2 Ø 21 0 8 Label posted here Ø Y Ø 60 min 18 4 max 12 4 Parts mounted Empty leader 400 mm min 100 mm min with cover tape Direction of pulling out Empty trailer 200 mm min X 2 1 8 2 4 Ø 1 5 1 75 0 3 5 5 12 Technical drawings according to DIN specifications Drawing No 9 700 5380 01...

Page 8: ...e absorption The following conditions should be observed if dry boxes are not available Storage temperature 10 C to 30 C Storage humidity 60 RH max After more than 168 h under these conditions moisture content will be too high for reflow soldering In case of moisture absorption the devices will recover to the former condition by drying under the following condition 192 h at 40 C 5 C 0 C and 5 RH d...

Page 9: ...ecific data BAR CODE PRODUCT LABEL example 1 Calculated shelf life in sealed bag 12 months at 40 C and 90 relative humidity RH 3 After bag is opened devices that will be subjected to reflow solder or other high temperature process must be 4 Devices require bake before mounting if a Humidity Indicator Card reads 10 for level 2a 5a devices or 60 for level 2 devices when read at 23 5 C b 3a or 3b are...

Page 10: ...s are not binding statements about the suitability of products for a particular application It is the customer s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application Parameters provided in datasheets and or specifications may vary in different applications and performance may vary over time A...

Reviews: