- Kit amplified outputs
CONFIGURATION OF THE AMPLIFIED AUDIO OUTPUTS
GRAPHIC EQUALIZER
In order to start the display screening.
1.
Recall
MENU
:
________
ORGAN STYLE
VOICES
TEMPERAMENT
íäìõ_______Ö
2.
Through button [FIELD
] set the cursor on field “
SET UP
” and press [ENTER]:
_______òäô õï______Ö
TREMULANT
REVERBERATION
EQUALIZER
3.
Through button [FIELD
] set the cursor on field “
EQUALIZER
” and press [ENTER]:
___EQUALIZER íäìõ___
INT. EQUALIZER
EXT. EQUALIZER
SpkOUT EQUALIZER
4.
Through button [FIELD
] set the cursor on field “
SpkOUT EQUALIZER
” and press [ENTER]
and you will see the parameters for the equalizer adjustment in the display.
____SPK OUT. EQ.____
_
FREQ:
60 Hz
ØØ ª
GAIN: +4
dB
ØØØØØ
5.
The displayed parameters and ist functioning are the same as those of the equalizers for the internal
amplification and line outputs. Please revert to the organ owner’s manual.
13