EN - 56
Legend ‘70s
– User Manual
System menu
PEDAL SETUP section
The
PEDAL
SETUP
menu provides the parameters to configure the pedals connected to the PEDAL jack on the
rear panel.
To access this menu, enter the
SYSTEM
page and place the cursor on the
PEDAL SETUP
field, then press the
data entry dial.
Parameter name
Description
Sustain Type
Type of pedal connected to the PEDAL [SUSTAIN] connector.
Values:
Half-Damper:
continuous control sustain pedal, to be used with the half-pedaling technique.
Switch:
foot switch.
Triple:
Studiologic SLP-3D triple pedal.
Sustain Polarity
Polarity of the pedal connected to the PEDAL [SUSTAIN] connector.
Values:
Auto:
polarity is automatically detected when switching on the instrument.
Open
(when
Sustain Type: Switch
)
:
Normally open pedal (N.O.)
Closed
(when
Sustain Type: Switch
)
:
Normally closed pedal (N.C.).
Type1
(with
Sustain Type: Half-Damper
)
:
pedal such as Yamaha FC3A.
Type2
(with
Sustain Type: Half-Damper
)
:
pedal such as Roland DP-10.
NB
-
Do not press the pedal while switching on the instrument and when selecting polarity.
-
This parameter has no effect if
Sustain Type
is set to
Triple
.
Sustain Range
Position and range covered by the pedal connected to the PEDAL [SUSTAIN] connector. This
page also allows the user to calibrate the sustain pedal (page
Values:
between 0 and 100%
FS1 Polarity
FS2 Polarity
Polarity of the foot switch connected to PEDAL [FOOT SWITCH 1] and [FOOT SWITCH 2].
Values:
Auto:
polarity is automatically detected when switching on the instrument.
Open:
normally open pedal (N.O.).
Closed:
normally closed pedal (N.C.).
NB
Do not press the pedal while switching on the instrument and when selecting polarity.
FC1 Type
FC2 Type
Type of foot controller connected to PEDAL [FOOT CONTROLLER 1] and [FOOT CONTROLLER
2].
Values:
Type1:
pedal with RTS connector, such as Yamaha FC7.
Type2:
pedal with TRS connector, such as Fatar VP/25.
TYPE 1
TYPE 2
FC1 Range
FC2 Range
Position and range covered by the pedal connected to PEDAL [FOOT CONTROLLER1] and
[FOOT CONTROLLER 2].
This page also allows the user to calibrate the foot controller (page
Values:
between 0 and 100%
Prog +/- Polarity
Polarity of the two-switch foot switch connected to PEDAL [P / -].
Values:
Auto:
polarity is automatically detected when switching on the instrument.
Open:
normally open pedal (N.O.).
Closed:
normally closed pedal (N.C.).
NB
-
When using a two-switch foot switch with opposite polarities, select the
Auto
setting.
-
Do not press the pedal while switching on the instrument and when selecting polarity.
Ring
Ring
Sleeve
Tip
Tip
Sleeve
Ring
Sleeve
Tip
Tip
Sleeve
Ring
Wiper
GND
Supply
Supply
GND
Wiper
Summary of Contents for Legend '70s Artist
Page 1: ...Edition 1 0 User Manual EN Manuale Utente IT ...
Page 2: ......
Page 70: ......
Page 144: ......
Page 145: ......