19 / 36
4.1.6
Feeding material and bleeding the dispenser for the first time
Connect the material supply (feed line, cartridge) to the material inlet (1A and 1B) of
the dispenser.
Place the eco-DUOMIX in a vertical position.
Mount the calibration adapter (36).
On both dispenser halves perform
Tip:
Connecting a hose to the calibration adapter can protect the eco-DUOMIX450 from
being wetted with the material.
* When filling for the first time, the blocking medium is first removed from inside the
dispenser (stator).
Pressurise the material.
Connect the drive unit to the power supply
and run it slowly until material escapes
from the calibration adapter (36) without
bubbles.*
Unscrew the bleed screw (12) and sealing
washer (8) to bleed.
Tighten the bleed screw (12) and the
sealing washer (8) again.
Remove leaking material with a cloth.
NOTE
When cleaning the dispenser, never use the same cloth for both materials,
as the components will react.
Fig. 11
S12345
S12
34
5
ec
o-PE
N45
0
ec
o-DUO
1A
1B
8
12
C
36