CRU/MD1U/VRU-SERIES 

Installation Instruction  

ERP: IIS00217 

Recessed Grid (T-Bar) 

Hard Ceiling Flange Cont’d 

Size 

Width 

Length 

1x2 

10-7/8 in. 

22-7/8 in. 

1x3 

10-7/8 in. 

34-7/8 in. 

1x4 

10-7/8 in. 

46-7/8 in. 

2x2 

22-7/8 in. 

22-7/8 in. 

2x4 

22-7/8 in. 

46-7/8 in. 

Ceiling Cut-Out Dimensions: 

1.  Fixture is designed for use with 1”/1 ½” T-bar grid systems with vertical 

grid T thickness of less than 1/4” with a maximum height of 1 ½”. Grid 

systems can be installed standard 12, 24 or 48” centerline spacing of 

grid. 

2.  Fixture housing lays into grid. Ensure four (4) swing arms are in the 

stowed position as shown. If securing fixture to the superstructure with 

hanger wire (by others) loop wire through holes on swing arm attach 

bracket. Position door frame into housing opening and start all screws by 

hand. Tighten all screws to seal door frame to fixture. 

Frame (not supplied) 

1-5/8” Unistrut (or equal) 

Ceiling cut-out 

Swing-out Support Brackets 

(4-pcs) 

Width 

Length 