![Visco IT-OUT250 User Manual Download Page 5](http://html.mh-extra.com/html/visco/it-out250/it-out250_user-manual_1030733005.webp)
www.viscoo.eu
By default,there are two master cards marked
MASTER CARD ADD
and
MASTER
CARD DELETE
,but you should know that the master card can be authorized by users
at any time.That means any two user cards can be authorized to master cards,When
registered new master cards, the old master cards are invalid automatically.
Authorize master cards:
7.Unlock Operations
Unlocking of ID Card
When the registered user card has been shown to ID card window, the LED indicator
(the first lock:red; the second lock:blue) lights up, the buzzer sounds,and the electric
door strike is unlocked.
Note1:if the user card control one lock only,show the user card to release the first
lock.red indicator lights up.
Note2:if the user card control two locks,show the user card to ID card window in
standby mode,the red&blue indicator blink for 1.5s alternately. During this ti-
me,press "CALL" button to release the second
lock.Otherwise,release the first lock if there
isn't any operation within 1.5 seconds.
• If 10 times unauthorized access cards are continuously attempted, the release
function is forbidden and the showing card operation is disabled for 60 seconds.
• When DIP3 switch is set to 1,the relay 2 doesn't respond the second lock,that's to
say,showing user cards controlled two locks or pressing unlock 2nd on monitor
can not release the second lock.During this time,After continuously showing ac-
cess card 10 times,the relay 2 will be closed for 60 seconds,the blue LED-relay 2
will be illuminated for 60 seconds,and the buzzer will continuously sound about 8
times.If the system is connected alarm,the alarm function will be activated.
www.viscoo.eu
IT-OUT250-F Mounting
Adjusting Camera Angle