CONNECTING YOUR WIRELESS SECURITY SYSTEM
ING YOUR WIRELESS SECURITY SYSTEM
ING YOUR WIRELESS SECURITY SYSTEM
ING YOUR WIRELESS SECURITY SYSTEM
4
5
6
3
2
1
AWAY
OFF
HOME
DC INPUT
TERMINAL BLOCK
RESET
VOLUME
SIREN
TEL
LINE
Note: Please make sure to disconnect all power inputs,
including the back-up batteries, before taking apart the
front cover for necessary technical checking.
DC POWER INPUT (DC INPUT or E+/E-)
The power supply of 12VDC 1A should be plugged into the DC
socket, or connected to these 2 terminals, for the control
console operation.
Note
: Please note the polarity when connecting the power
supply. E+ for “+12VDC” and E- for “Common“.
MANUAL RESET SWITCH [RESET]
If an unexpected alarm is caused during the installation, press
this button once to stop the alarm and reset the control console
back to the power-on status. In addition, use this button, with
AWAY and OFF buttons, when proceeding the default process.
VOLUME ADJUSTMENT [VOLUME]
Turn clockwise to the maximum volume of the voice indication
sound level from the internal speaker unit. Turn
counterclockwise to the minimum volume.
VOLUME ADJUSTMENT [SIREN]
Turn clockwise for the maximum volume of the alarm sound
level from the built-in siren unit. Turn counterclockwise to the
minimum volume.
HOUSE PHONE LINE CONNECTOR [TEL]
To connect the telephone line to your house phone set.
INCOMING PHONE LINE [LINE]
To connect the incoming telephone line directly from the phone
jack box installed by the local telephone company.
TERMINAL BLOCKS
CONTINUOUS DC POWER OUTPUT (12V OUT)
A reg12VDC 500mA power output can be supplied for
the general purpose, like the externally connected detectors and
sensors that require the non-stop operation.
COMMON CONNECTION (GND)
A common connection point is provided for wiring connection
purpose.
GENERAL ALARM OUTPUT (ALARM / COM.+N.O. or N.C.)
A 1A dry relay N.O. or N.C. contact is provided for the
programmable alarm output. When the specified alarm(s)
activated, the relay contact will be engaged until the pre-set
alarm time expired. [See section 3
-6-2
]
24-HOUR ALARM OUTPUT (24HRS. / COM.+N.O.)
A 1A dry relay N.O. contact is provided for the general alarm
output. When any 24-hour (i.e. Panic, Medical, Fire, HOME
and Tamper) alarm(s) activated, the relay contact will be
engaged until the pre-set alarm time expired.
LATCHED ALARM OUTPUT (LATCH / COM.+NO.)
A 1A dry relay N.O. contact is provided for the latched alarm
output. When any (i.e. Burglary, Panic, Medical, Fire, HOME
and Tamper) alarm(s) activated, the relay contact will be
engaged until the control console is disarmed.
REMOTE ARM/DISARM INDICATION OUTPUT (ARM)
A
SINK type
voltage will be output during the arming/armed
time period to turn on the ARM LED on the Remote Indication
unit. This voltage will be disconnected at the moment of
disarm command is executed.
REMOTE ALARM INDICATION OUTPUT (ALARM)
A
SINK type
voltage will be output during the alarm time to turn
on the ALARM LED on the Remote Indication unit.
COMMON CONNECTION (GND)
A common connection point is provided for wiring connection
purpose.
TAMPER SWITCH INPUT (TAMP)
Accepts the N.C. type pulse input from the externally connected
tamper switch activation.
WIRED N.C. SENSOR INPUT (BUR1 & BUR2)
Accepts only the N.C. type pulse input from the externally
connected burglary sensors for Zone 24 & Zone 25 protection
purpose. [See sections
3.1.10
&
3.2.10
]
COMMON CONNECTION (GND)
A common connection point is provided for wiring connection
purpose.
REMOTE ARM/DISARM SWITCH INPUT (KEYIN)
A
MOMENTARY
type Key-switch/Keypad can be connected for
the remote arming/disarming purpose and only available for the
AWAY
mode operation.
Note: HOME
mode operation is not available.