7. ADJUSTING THE BIT HEIGHT

Disconnect the machine from the mains 

before making any adjustments to the 

machine

Protector C does not need to be removed in order to 
adjust the bit height (Fig. 4).
Loosen screw D (Fig. 4) using key E (Fig. 4) until the mo-
tor body F can move. Turn the eccentric G (Fig. 4) using 
the same key E (Fig. 4) until the edge of the cutter bit 
with radius H (Fig. 5) is level with the base I (Fig. 5) and 
firmly tighten screw D (Fig. 4) in this position.

8. ADJUSTING THE FEELER

The machine includes feeler C (Figs. 5, 6 and 7) which acts 
as a support guide and determines the depth of same.
We advise routing the desired radius in two or three 
cuts in order to prevent vibrations and marks on the 
finished radius. The feeler must be adjusted for each cut.

First cut:

To adjust the feeler for the first cut, loosen screws J (Fig. 
6) with spanner E (Fig. 6) and move the feeler forward 
until it can go no further.

Last cut:

To adjust the feeler for the last cut, loosen screws J (Fig. 
6) and move the feeler until the edge of bit H (Fig. 6) is 
level with the feeler. Since the bit is spiral, you will have 
to turn it 360° in order to check this (Fig. 6).
To ensure that the edge and the feeler are accurately 
aligned, use support ruler K (Fig. 6). Once the correct 
position of the bit has been established, tighten screws 
J again (Fig. 6).

Intermediate cut:

Should you wish to make the radius in 3 cuts, place the 
feeler in an intermediate position, between the two 
positions explained above.
Before routing radius (Fig. 7) on the work top, do a test 
trim to check that the height of the cutter bit and the 
position of the feeler are correctly set.

9. CHANGING THE BIT

Make sure you place the chuck collet in 

the correct position, otherwise vibrations 

may occur or the part itself my come 

loose (Fig. 12).

Disconnect the machine from the mains 

before performing this operation.

 

To change the cutter bit, first remove the feeler C (Fig. 
6), removing the screws J (Fig. 6). Block the motor shaft 
using key L, unscrew the nut with the key M (Fig. 8), 
remove the worn bit and insert a new one. Hold it in 
position by tightening the nut with key M and let it slide 
until the edge rests on the support surface.
Adjust the height of the bit, as explained in the cor-
responding section (Fig. 5).

10. MAINTENANCE. CARBON 
BRUSHES AND COMMUTATOR

Disconnect the machine from the 

power supply before any maintenance 

operation.

 

Remove the screws N (Fig. 9) that hold the side covers 
O (Fig. 9) and separate them. Remove the brush-holder 
P (Fig. 10) with small screwdriver Q, using one of the 
brush-holder side tabs to lever it out. Push back the end 
of spring R. Keep it in this position to remove the brush 
and replace it with a new genuine Virutex brush. Reinsert 
the brush-holder, ensuring that it is firmly positioned in 
the casing and that each of the brushes exerts a small 
amount of pressure on the collector. Re-attach the 
covers O with the corresponding screws, making sure 
that no wires get caught in the process. It is advisable 
to leave the machine running for 15 minutes after the 
brushes have been changed.
If the collector burns or juts out, it should be serviced 
by a VIRUTEX technical service. Always keep the cable 
and plug in good service condition.

11. LUBRICATION AND CLEANING

The machine comes fully lubricated from the factory and 
does not require special care during its working life. It is 
important to always clean the machine carefully after 
use with a dry air blower.
Keep the power cable in perfect working condition.

12. NOISE LEVEL AND VIBRATIONS

The noise and vibration levels of this device have been 
measured in accordance with European standard EN 
60745-2-17 and EN 60745-1 and serve as a basis for com-
parison with other machines with similar applications.
The indicated vibration level has been determined for 
the device’s main applications and may be used as an 
initial value for evaluating the risk presented by expo-
sure to vibrations. However, vibrations may reach levels 
that are quite different from the declared value under 
other application conditions, with other tools or with 
insufficient maintenance of the electrical device or its 
accessories, reaching a much higher value as a result 

Summary of Contents for FR217S

Page 1: ...Affleureuse d angle Eckentrimmer Fresatrice per angoli Fresadora de topos Frezarka k towa FR217S MANUAL DE INSTRUCCIONES OPERATING INSTRUCTIONS MODE D EMPLOI GEBRAUCHSANWEISUNG MANUALE D ISTRUZIONI MA...

Page 2: ...ngle FR217S 9 DEUTSCH Eckentrimmer FR217S 12 ITALIANO Fresatrice per angoli FR217S 14 PORTUGU S Fresadora de topos FR217S 17 FR217S 19 OLSKI Frezarka k towa FR217S 22 MANUAL DE INSTRUCCIONES OPERATING...

Page 3: ...3 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 C...

Page 4: ...deconectarlam quina quelatensi n dealimentaci n correspondaconlaindicadaenlachapa de caracter sticas Mantenga siempre las manos alejadas del rea de corte y sujete siempre la m quina por el cuerpo cent...

Page 5: ...elA 99dBA Uncertainty K 3dbA Wear ear protection Vibrationtotalvalues ah 2 5m s2 Uncertainty K 1 5m s2 3 STANDARD EQUIPMENT Inside the box you will find the following items 1 FR217S Angle trimmer 2 H...

Page 6: ...the nut with the key M Fig 8 remove the worn bit and insert a new one Hold it in position by tightening the nut with key M and let it slide until the edge rests on the support surface Adjust the heigh...

Page 7: ...he product for environmentally friendly and safe recycling VIRUTEX reserves the right to modify its products without prior notice F R A N A I S FRAISEUSE D ANGLE FR217S Important Avant d utiliser la m...

Page 8: ...w virutex es registre Acceda a toda la informaci n t cnica Access to all technical information Acc s toute l information technique Zugang zu allen technischen Daten Accedere a tutte le informazioni te...

Reviews: