VIRUSKILLER VK-blue User'S Manual & Instructions Download Page 1

 

 

 
 
 
 

World Leading Air Sterilization and 

Purification Equipment 

VK-Blue 

 

 

USER GUIDE & INSTRUCTIONS 

 

 

 
 

 

 
 
 
 
 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 

 

Sales & Design: Radic8 Ltd 

Man & Scythe Building 6 - 8 Churchgate Bolton, BL1 1HL

, UK  

Tel : +44 (0)1204 238823, E-mail: info

@radic8.com

www.radic8.com

 
 

Manufacturer: INBair Co., Ltd 

3F, 15, Beotkkot-ro 12-gil,Geumcheon-gu, Seoul, Korea 

Tel: +82-31-811-1000, E-mail: inbair01

@naver.com

www.inbair.com

 

Made in Korea,  Designed in England

 
 

 
 
 
 
 
 
 
 
 

 

 

 
 

Summary of Contents for VK-blue

Page 1: ...esign Radic8 Ltd Man Scythe Building 6 8 Churchgate Bolton BL1 1HL UK Tel 44 0 1204 238823 E mail info radic8 com www radic8 com Manufacturer INBair Co Ltd 3F 15 Beotkkot ro 12 gil Geumcheon gu Seoul Korea Tel 82 31 811 1000 E mail inbair01 naver com www inbair com Made in Korea Designed in England ...

Page 2: ...tant safety instructions that must be followed to avoid injury Caution This symbol is to bring important information to your attention to avoid the risk of injury or damage to the unit Prohibited This symbol indicates a forbidden action Adhere to these to reduce the risk of injury or damage to the unit Electrical Safety The unit should only be connected to a properly grounded mains power supply wi...

Page 3: ...customer services 3 of 20 Operation Instructions Switch off while cleaning the room After cleaning it is important to properly ventilate the room before using VirusKiller again Switch off while cooking Oils released while cooking may reduce the lifespan of the sterilizing module After cooking the room should be ventilated to remove oils VirusKiller can then be used to remove the remaining smell En...

Page 4: ...at a burning ultra violet light this may permanently damage your eyes Switch off and unplug before performing maintenance Key Parts and Components 1 Air Inflow 2 Santized and Purified Air Outflow 3 Fan 4 Dual Reactor Module Left and Right 5 8 x UVC Lamps and Multiple Nano Tube Filters 6 Fragrance Pod 7 Pre Filter 8 HEPA Filter 9 Carbon Filter Left and Right 5 of 20 Wall Mounting The Reactor Module...

Page 5: ...ller Functions Manual Operation Mode When the power button is pressed the unit emits a beep sounds and begins to operate If the product does not operate ensure the socket is plugged securely into a live properly grounded outlet of the correct voltage 8 of 20 ...

Page 6: ...creases when the UP button is pressed FAN 1 Quiet Mode FAN 2 Normal Mode FAN 3 High Speed Mode 9 of 20 Reducing the Fan Speed Pressing the DOWN button decreases the fan speed FAN 1 Quiet Mode FAN 2 Normal Mode FAN 3 High Speed Mode 10 of 20 ...

Page 7: ... on the remote controller 2 Press MODE button on main body Press either TIMER or MODE to toggle between the timer preset options The unit will automatically switch off when the programme time has passed Pr 3 3 hours preset Pr 6 6 hours preset Pr 9 9 hours preset 12 of 20 ...

Page 8: ...lowing order 0001 Operation time in hours of Sterilizing Module _27d Current temperature FAN3 Fan Speed 13 of 20 To Switch the Unit Off To switch the unit off press the POWER button on the unit or on the remote control Turn the product off and unplug power cord when it is not in use for an extended period of time 14 of 20 ...

Page 9: ...of 20 Replacing the HEPA Filter When the display shows FILT at 2 minute intervals it is time to replace the HEPA filter 2000 hours After replacing the HEPA filter press and hold the UP switch for at least 14 seconds to reset the HEPA timer to zero Changing the Side Carbon Filters After switching off the power open side filter door and replace carbon filter then close the door The HEPA and carbon f...

Page 10: ...8000 hours the operation time displayed by pressing MODE will be a minus figure as shown below The Sterilizing Module should be replaced when recommended otherwise the sterilizing power and the lifespan of the unit will be reduced Circuit overheat error The below error message is displayed when the circuit is overheated Switch off the unit and contact the customer service center Door Open If the d...

Page 11: ... Solutions Replace HEPA filter 19 of 20 Possible Causes Check the room size compared to the product specifications Solutions Select the appropriate model of VirusKiller to suit the space to be covered Possible Causes Check if airflow is restricted Solutions Make sure there is sufficient clearance around the product and that the air inlet and outlet are not blocked by furniture curtains etc Problem...

Page 12: ...pply or output voltage 5 Breakdown or loss of parts caused by unauthorized disassembling or modification 6 Repair or replacement undertaken by unauthorized persons 7 Damages caused by non adherence to the instructions provided in this user guide and as given by the local customer service center 8 Damages caused by careless or improper use 9 Damages caused by operating the product in a corrosive or...