PART A: Basic machine
Shredder
L 60; L60+
©
VIRTUS EQUIPMENT 2018 All rights reserved
Page 33
6.2
Requirements at the application site
The site of application for the machine must exhibit the following
features:
•
Enclosed space.
•
The ground must exhibit sufficient load-bearing capacity (you
can find the machine weight in the C
hapter Technical Data
).
The unevenness of the ground surface may not exceed 5 mm.
•
The machine must be freely accessible from all sides.
•
There must be sufficient room available for operating and
service personnel.
•
Spatial requirements: see
Assembly drawing
. All hinged parts
must be able to be opened completely.
•
Vibration-free environment.
•
The application site must be well-lit.
•
The machine may not be exposed to direct radiation caused by
radiators or the sun.
•
Room temperature: +5° to +40°C
•
Relative atmospheric humidity according to DIN 40040:
15 to 70 % (indoor)
By humidity levels higher than 70 %, apply anticorrosive
agent to the metallic-finished machine parts. Insulation for the
tropics is also necessary.
•
The machine may not be operated within range of static
discharges or strong magnetic fields as this could lead to faults
in the machine control system.