MOUNTING/INSTALLATION GUIDE

OPERATION

Soulis serves as a continuous, proactive air defense system to provide minimal risk in indoor

environments by eliminating airborne viruses, surface pathogens, as well as mold and bacteria. 

Soulis has 

99.99% pathogen reduction

 efficacy testing. (Assured Bio, Oak Ridge, TN.)

Soulis  is  intended  for  use  indoors  in  healthcare  facilities,  fitness  facilities,  nursing  home 

facilities, places of worship, municipal facilities, educational institutions, large venues, etc.

Upon receipt of Soulis check for any potential damage and inclusion of all equipment required 

to use the device properly. Refer to Device Description for components.

To avoid electric shock and device damage, plug into an appropriate 115V outlet using the 

power cord provided. Secure any hanging power chords to U shaped Hanging Yoke provided 

in packaging.

Do not obstruct airflow to or from the device.

Soulis is required to be ceiling or wall-mounted above 7ft with a required 115V 115v recepticle 

if hard mounted with Ventorlux provided mounting equipment.

Soulis should only be placed in a location that allows for maximum airflow into and out of the 

unit.

To engage Soulis connect power cord and click the switch ON(I). To turn Soulis off, click the 

switch OFF(O).

Cleaning the outside of Soulis is not considered maintenance and may be performed by 

the operator. Use a dry rag to remove dust from the device exterior. The device must be 

disconnected from the power source before cleaning.

Changing a fuse is not considered maintenance and may be performed by the operator. To 

change the fuse safely the following steps are provided:

1. 

Disconnect/unplug the device from the 115V power source.

2. Remove the fuse from its holder. (Additional fuse secured inside fuse holder)
3. Inspect the fuse wire. If there is a visible gap in the wire or a dark or metallic smear 

inside the glass then the fuse is blown and needs to be replaced.

4. Replace the fuse.
5. After moving, cleaning, or changing the fuse the unit must be reinstalled or 

remounted as previously installed before operation.

WARNING: 

 T

o reduce the risk of electric shock, do not expose to water.

This device contains UV lights which can be harmful to skin and eyes if misused or tampering of 

product occurs.   This product has tested safe for use in occupied spaces for humans, pets, plants, 

and food.

Summary of Contents for SOULIS X1

Page 1: ...AIR PURIFICATION SYSTEM SOULIS X1 Summary Read Carefully to Ensure Proper Usage and Operation ...

Page 2: ...SOULIS X1 OPERATION SAFETY MANUAL ...

Page 3: ...CATIONS 6 04 INSTALLATION INSTRUCTIONS 8 05 OPERATION 10 06 PRODUCT FEATURES 12 07 MAINTENANCE 14 08 WARRANTY 16 TABLE OF CONTENT SOULIS X1 PROVIDES A SAFE ANSWER TO AIR PURIFICATION KILLING HARMFUL AIRBORNE MICRO ORGANISMS Read all safety warnings and instructions Failure to follow warnings and instructions may result in electric shock fire and or serious injury Do not attempt to tamper with the ...

Page 4: ...fuse is blown Replacing a fuse is not considered maintenance and may be performed by operator Prior to changing fuse disconnect the device from power supply and replace the fuse as outlined in Operating Instructions In the event the device continues to short circuit discontinue use and contact the manufacturer at 706 992 8382 16 Removing dust accumulated on the outside of the device is not conside...

Page 5: ......

Page 6: ... designed to be ceiling wall or floor mounted Each unit comes with a 3 8 threaded rod holding hole in the upper section of the hanging yoke as well as a wall or counter mount stand SOULIS X1 MOUNTING INSTALLATION GUIDE ...

Page 7: ...n a location that allows for maximum airflow into and out of the unit To engage Soulis connect power cord and click the switch ON I To turn Soulis off click the switch OFF O Cleaning the outside of Soulis is not considered maintenance and may be performed by the operator Use a dry rag to remove dust from the device exterior The device must be disconnected from the power source before cleaning Chan...

Page 8: ...other micro organisms by cycling air through the device s Photolysis Chamber The air is then exposed to a specific frequency of UVC light causing the Pathogens and other micro organisms to be modified or destroyed The Photolysis chamber ensures no UVC light or Radiation can escape the chamber making it safe to use around people without the use of PPE Personal Protection Equipment Diagram Definitio...

Page 9: ...ctric shock or injury to persons disconnect Soulis from the power supply before cleaning or changing the fuse Cleaning the outside of Soulis is not considered maintenance and may be performed by the operator See Operating Instruction for details Changing a fuse is not considered maintenance and may be performed by the operator SoulisParticle Filters are required during operation 2 Soulis particle ...

Page 10: ...Use this unit only in the manner intended by the manufacturer If you have questions contact customer service at 706 992 8382 1 Grasp plug and remove from the receptacle or other outlet device Do not unplug by pulling on cord 2 Open fuse cover in the center 3 Remove fuse carefully from the fuse holder Grab on both ends 4 Risk of fire Replace fuse only with a 5 amp fuse 5 Insert and close fuse cover...

Page 11: ...Y THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND OBLIGATIONS OF VentorLux OR ITS SUPPLIERS EXPRESS OR IMPLIED VentorLux EXPRESSLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE LIMITATION OF REMEDY Under no circumstances shall VentorLux or any supplier of VentorLux be liable for any loss or damage including but not limited to loss or damage ...

Page 12: ...nfecting chamber discharging disinfected air providing a pathogen free space Tested 100 safe for occupied spaces Soulis is safe for use in the presence of humans animals plants and food and offers 24 7 proactive disinfection of the air Soulis creates approximately 300 Cubic Feet per Minute CFM of clean air creating pathogen free environments Surrounding air is safely and quickly disinfected greatl...

Page 13: ......

Page 14: ......

Page 15: ...NOTES ...

Reviews: