THE RXAIR PORTABLE AIR PURIFIER 

 
Thank you for purchasing a ViraTech RxAir 
portable Air Purification unit. Use this 
product with confidence that it is 
engineered to efficiently kill microbial 
contaminants in your indoor environment.   
 
We recommend that you operate your 
RxAir whenever the property is occupied 
since indoor air is constantly being 
contaminated from a variety of sources. 
 

MAJOR COMPONENTS    

            

The ViraTech RxAir is a flow through indoor 
air purification system which kills over 99% 
of airborne bacteria, as well as other 
contaminants that can cause allergic 
reactions or respiratory issues. It is cleared 
by the FDA as a Class II Medical Device for 
killing bacteria. It is appropriate for any 
hospital, residence or commercial 
establishments concerned about the health 
issues caused by indoor air pollution. 
 

BEFORE USE & PLACEMENT 
 

Carefully remove the unit from the box, 
and set aside all packaging materials. 
 
The unit should be placed in a location 
which pulls the contaminated air away 
from the living or sleeping space. For 
example, in a bedroom, unit could be 
placed in the corner of the bedroom 
furthest from the head of the individual, 
thus pulling untreated air away from 
sleeping individual.  In salons or other 
commercial business, units should be 
placed in the furthest corner from waiting 
area and application area. For highest 
performance and effectiveness always 
place unit furthest from individuals, 
drawing untreated air away from staff 
and customers. 
 

OPERATION of CONTROLS 
 

All controls for the ViraTech RxAir are 
located near the top of the unit.  
 

 

Center button turns unit ON and OFF. 
Momentarily depress this button to 

turn unit on. Press again to turn the 
unit off. 

 

Arrow shaped buttons control fan 
speed. Depress the button repeatedly to 
adjust fan speed to desired level. The 
left button decreases fan speed while 
the right button increases fan speed. 

 

When Maximum or Minimum Speed is 
reached, unit beeps. 

 

 

CHANGING THE SCREEN AND 
CARTRIDGE

 

 

The cartridge is engineered as a sealed 
unit. It is not user serviceable. NO attempt 
should be made to remove end caps to get 
inside the cartridge. Doing so could pose a 
health threat and will void the limited 
warranty.   
 
The cartridge should be changed when the 
indicator turns from GREEN to AMBER or 
STEADY RED. This occurs typically after 
8800 hours of operation (1-4 years based 
on daily hours of use). YOU MUST UNPLUG 
THE UNIT FOR ONE MINUTE TO ALLOW 
THE UNIT TO RESET.  

 
 
 

 
 
 

PARTICULATE SCREEN

 

The particulate screen should be checked 
every 1-3 months. If there are heavy 
concentrations of contaminants in your 
indoor environment, such as pets or dust, 
you need to clean or change the screen 
periodically. To clean, use a mild detergent, 
followed by a thorough rinse with hot water, 
dry and replace. For particulate screen 
replacement see diagram above. 
Replacement cartridges are available where 
RxAir Air Purifiers are sold. Each replacement 
cartridge comes with 4 particulate screens. 

*   Please   check   state   and   local   requirements   
regarding   disposal   of   the   UV   Lamp.      

   

2   

3   

4   

5   