background image

About sleeve cleaning:
Minerals in the water slowly form a coating on the sleeve. This coating must be removed because it 
reduces the amount of UV light reaching the water, thereby reducing disinfection performance. 

About lamp replacement:
The amount of UV light created by the lamp decreases over time, requiring that the lamp be 
replaced. The system will automatically notify you when it is time to replace the lamp (the lamp 
should last approximately 24 months). 

Equipment required:

Cloth must be 

soft, lint-free, and 

chemical-free. No 

clean-wipes. 

Scale remover 

such as CLR

TM

 or 

Lime-Away

TM

#2 Phillips 

screw driver 

Cotton swab. 

Clean cotton, 

latex or plastic 

gloves are 

preferred.

Part

Lamp

Sleeve

Length

UVMAX G & Pro10

602854

602974

15.1“

UVMAX H & Pro20

602855

602975

26.7“

UVMAX J, K & Pro30, Pro50

602856

602976

36.5“

Reviews: