WARNING – 

To guard against injury, basic safety precautions should be observed, including the following:

1.   READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

2.   DANGER – To avoid possible electric shock, special care should be taken since water is employed in the use of this system. 

Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do 
not attempt repairs yourself; refer to an authorized service facility.

3.   CAUTION - Do not operate with broken or faulty parts as this may result in exposure to ultraviolet radiation. Contact supplier 

for replacement parts.

4.  Do not operate the system if it has a damaged cord or plug, or if it is malfunctioning or if it has been dropped or damaged in 

any manner.

5.   Always unplug the system, shut off water flow and release water pressure before servicing or cleaning. Never yank cord to 

remove from outlet; grasp the wall plug and pull to disconnect.

6. 

 Do not use the system for other than intended use. The use of attachments not recommended or sold by the manufacturer may 
cause an unsafe condition.

7. 

To prevent risk of electrical shock, connect this system only to a properly grounded, grounding-type power supply receptacle 
that is protected by a Ground Fault Circuit Interrupter (GFCI). Inspect performance of GFCI as per manufacturer’s suggested 
maintenance schedule. If an extension cord is used, ensure it is of a sufficient rating and accepts the plug from this system; 
never use an adapter.

8.   Visually inspect this system prior to installation. If the quartz sleeve or lamp is broken, cracked or damaged in any way, do not 

use. Contact the supplier for replacement parts.

9.   Keep all connections dry and off the ground. Do not touch plug with wet hands.
10.   The light emitted by the lamp will cause serious eye damage and burn unprotected skin. Do not plug system into an electrical 

outlet without first properly securing the lamp into the chamber. Unplug the system prior to removing the lamp from the 
chamber. 

11.   If the UV system malfunctions or fails, water must be boiled prior to consumption until the UV system is operational and the 

water lines have been shocked. System failure is indicated by the system’s audible and visual alarms or the absence of any 
indicator light.

12.   Intended for indoor use only. System must not be exposed to weather elements. In seasonal applications, chamber must be 

drained to prevent freezing.

13.   Installation of this system must be in accordance with local plumbing and electrical codes as well as any and all applicable 

regulations and laws.

14.   SAVE THESE INSTRUCTIONS.

SAFETY INSTRUCTIONS

GROUNDING

This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current 
to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding 
plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and 
ordinances.

DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified 
electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with 
this system – if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use any type of adapter with this 
system.

GROUND FAULT CIRCUIT INTERRUPTER PROTECTION

To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this system 
should only be connected to a properly grounded, grounding-type power supply receptacle that is protected by a Ground Fault Circuit 
Interrupter (GFCI). Inspect operation of GFCI as per manufacturers suggested maintenance schedule.

EXTENSION CORDS

If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors 
that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an 
electrical rating not less than the rating of the system.  A cord rated for less amperes or watts than this system rating may overheat. 
Exercise caution when arranging the cord so that it will not be tripped over or pulled. Do not use damaged extension cords. Examine 
extension cord before using and replace if damaged. Do not abuse extension cord. Keep extension cord away from heat and sharp 
edges. Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank 
cord to pull plug from outlet. Always grasp the plug and pull to disconnect.

WARNING – To prevent risk of electrical shock, connect this system only to a properly grounded, grounding-

type power supply receptacle that is protected by a Ground Fault Circuit Interrupter. Pull plug before 

servicing or replacing lamp. Keep all connections dry and off the ground. Do not touch plug with wet hands.

WARNING – Read manual before installing or servicing this system. Only authorized personnel possessing  

a strong understanding of this system should attempt to replace lamp or service this system. 

WARNING – Do not look directly at UV lamp when it is operating. The light emitted by the lamp will cause 

serious eye damage and burn unprotected skin. 

NOTE – Maximum pressure rating is 125 PSI (8.62 bar)

Summary of Contents for IHS-10

Page 1: ...a only t 31 73 623 8116 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Model IHS12 D4 and IHS12 D4 2 Date of installation Installed by Installer phone Serial Found on label on side o...

Page 2: ...his product must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electrical shock This system is equipped wit...

Page 3: ...OF CONTENTS Overview 4 Specifications 5 Components 6 Dimensions and layout 8 Installation 9 Installing the UV system 9 Disinfecting the water lines 11 Operation 13 Control panel 13 Troubleshooting 14...

Page 4: ...7 grains per gallon Maximum iron 0 3 ppm Minimum UVT 75 Flow Rates Maximum rated flow at dose of 16 mJ cm2 16 GPM 60 LPM Maximum rated flow at dose of 30 mJ cm2 9 GPM 34 LPM Maximum rated flow at dos...

Page 5: ...QUA directly for a referral 1 800 265 7246 North America 519 763 1032 or info viqua com COMPONENTS 4 5 1 Components Power supply mounting bracket Reference card 603069 Power supply includes Power supp...

Page 6: ...05 O ring Sleeve bolt 602665 Sleeve includes O rings 602732 UV Chamber includes Chamber clamp s and Ring clamp Sediment filter 10 HIGH 5 micron CMB 510 HF Carbon filter 20 HIGH 5 micron C2 02 Bracket...

Page 7: ...al Intended to provide emergency water supply in the event that the UV system is unavailable Shut off valve Allows for ease of maintenance of whole home UV disinfection system Whole Home System Provid...

Page 8: ...ng holes located on the metal bracket The supplied lag bolts are suitable for attachment to wood Attachments to other materials will require purchasing of alternative hardware 3 1 2 4 5 7 8 Make all n...

Page 9: ...lace 10 Attach ground green yellow and strain relief red wires from the lamp plug to the ground lug on the chamber Secure both wires with locking screw provided 12 Ground lug Locking screw Ground and...

Page 10: ...the water lines is therefore required after initial system installation and following any period of time during which the system is inoperative whether due to an alarm condition a power failure or fo...

Page 11: ...ll bleach then stop the flow Repeat procedure at all water outlets Remember to include all faucets washing machines toilets outside taps and other water outlets Note You will likely run out of bleach...

Page 12: ...ghts only indicate a problem with the component when flashing red The table below is a list of possible causes and solutions Before replacing parts please contact VIQUA Technical Assistance for any ne...

Page 13: ...ipment downstream of UV system is acting as a breeding ground for pathogens Pathogens are residing in the distribution lines post UV Recontamination from pipe dead ends Ensure UV is the last piece of...

Page 14: ...OTE The UV system is designed to operate continuously and should not be shut off for short periods of time such as over a period of less than three weeks The system will automatically notify you after...

Page 15: ...lamp sleeve assembly Strain relief wires should remain connected Squeeze tabs 1 2 1 2 8 For sleeve cleaning only For lamp or sleeve replacement Clean sleeve and follow steps 9 12 Note Sleeve must be...

Page 16: ...s and sleeve bolt from sleeve Reinstall sleeve bolt with 2 new o rings Screw lamp into sleeve hand tight Caution Over tightening will break the sleeve 1 2 1 2 9 Lamp tab Sleeve bolt 2 1 Make sure lamp...

Page 17: ...Y 14 15 Push safety cap into place Align connections by rotating ring clamp to push lamp plug onto end of lamp ring clamp 17 If lamp was replaced Press and hold Lamp timer reset button for 5 seconds D...

Page 18: ...usage A gradual drop in water pressure after the filtration device is an indication that the pre filter cartridges are nearing the end of their useful life 3 4 5 10 6 7 2 8 1 9 Discard the used cartri...

Page 19: ...ations outlined under the heading General Conditions and Limitations below One Year Limited Warranty for Lamps and Sleeves VIQUA warrants original lamps and sleeves to be free from defects in material...

Page 20: ...520166 R Printed in Canada Copyright 2010 VIQUA aTrojanTechnologies Company Guelph Ontario Canada...

Reviews: