5.4 External control for « E » series (with pilot cable)
Changes of state are done by switching the common thread with one of the other four.
(See table above).
To change speed value, proceed as follows:
In «off» mode, press the keys
3 times (simultaneously).
6. PROTECTON & ERROR CODES
CODE
Default speed setting
Manual setting
1
Priming time
1 mn
0/10 mn
2
Minimum setting
speed
1200 rmp
1200/ 2900 rmp
3
H – washing speed
2900 rmp
1200/ 2900 rmp
4
M – day speed
2400 rmp
1200/ 2900 rmp
5
L – night speed
2000 rmp
1200/ 2900 rmp
6
Priming time
2900 rmp
1200/ 2900 rmp
Do not apply voltage on pilot wires.
+
Brown
=
L – night
Green
M – day
White
H – wash
Red
STOP
!