Chapter 2   Deployment TD 03

 

Manual VIPA HMI 

2-6 

 

HB116E - TD03 - Rev. 07/50 

Project engineering - Deployment TD-Wizard

 

 

TD-Wizard is a project engineering tool for the operating device TD 03 
from VIPA. The TD-Wizard allows you to create a data block that contains 
all parameters and messages for the TD 03. 

You may import the data block in the SIMATIC Manager from Siemens into 
your project and load it to the CPU. After the link-up of the TD 03 with valid 
MPI parameters, the according DB contents are transferred from the CPU 
to the TD 03.  

 

Start the TD-Wizard via double click on 

Type a file name for your STL-file and choose a storage directory or search 
for an already existing STL-file! 

Choose a data block number in Data Block ID. 

 

 

 

Confirm your settings with 

 

Overview

 

Create project 

Summary of Contents for TD 03

Page 1: ...Manual VIPA HMI TD 03 Order no VIPA HB116E_TD03 Rev 07 50...

Page 2: ...Lerrzeichen...

Page 3: ...l was carefully examined to ensure that it conforms with the described hardware and software However discrepancies can not be avoided The specifications in this manual are examined regularly and corre...

Page 4: ...eme of this chapter is the deployment and the project engineering of the TD 03 It contains information about the assembly the connection and the general handling of the TD 03 The chapter closes with a...

Page 5: ...oject engineering Overview 2 5 Project engineering Deployment TD Wizard 2 6 Commissioning 2 15 Operating the TD 03 Overview 2 17 Operating the TD 03 Menu mode 2 18 Firmware update of the TD 03 2 22 Ch...

Page 6: ...Contents Manual VIPA HMI ii HB116E TD03 Rev 07 50...

Page 7: ...following guides An overall table of contents at the beginning of the manual An overview of the topics for every chapter An index at the end of the manual The manual is available in printed form on p...

Page 8: ...must be available to all personnel in the project design department installation department commissioning operation The following conditions must be met before using or commissioning the components de...

Page 9: ...are required for the installation may also be found The chapter closes with the technical data Please consider the safety hints at the beginning of the chapter The following text describes Safety hin...

Page 10: ...s may fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection devices and meticulous attention to the applicable rules and r...

Page 11: ...ake the following precautions Floating instruments must be discharged before use Instruments must be grounded Modifying electrostatic sensitive modules you should only use soldering irons with grounde...

Page 12: ...gineering happens in the projecting tool TD Wizard from VIPA TD Wizard creates a data block containing your presetting that may be accessed by the CPU at need after the connection of the TD 03 Die cas...

Page 13: ...F3 F7 F8 Text Display 2 3 At the TD 03 the connectors are located at the backside VIPA 603 1TD00 X1 DC24V M P I 2 L M X 2 3 4 M 1 3 2 G Attention The simultaneous usage of external power supply and t...

Page 14: ...MP 2 I Multi Point Interface for connection to your CPU via a MPI network The MP2 I jack has the following pin assignment 9pin jack Pin Assignment 1 reserved must not be occupied 2 M24V 3 RxD TxD P Li...

Page 15: ...llation cutting with the dimensions 156mm x 78mm is required Installation values for control cabinets and desks Front panel width max 6mm Installation cutting W x H 156mm x 78mm Installation depth plu...

Page 16: ...ith LED back lighting Number of rows 2 Characters per row 20 Character height mm 5 Keyboard Foil keyboard with 9 keys Number of system keys 5 Function keys 4 Interface MP2 I 9pin D Type jack at the ba...

Page 17: ...iption of commissioning and operation of the TD 03 The chapter closes with a description of the firmware update The following text describes Fast introduction Installation Configuration Commissioning...

Page 18: ...ate Click on Enter the standard size and the number of your messages Click on In the appearing dialog window you can choose the areas where your data is stored in the DB Here normally no changes are n...

Page 19: ...o the CPU it is automatically started up TD 03 TD 03 SHIFT ESC ENTER F4 F3 F2 F1 F5 F6 F7 F8 Text Display 7 MP2I TD Wizard MPI CPU CPU MP2I DB For communication with the CPU the following parameters a...

Page 20: ...the installation in operating tables and control cabinet fronts you need the following front panel cutting 156mm 78mm The fixing technique is integrated in the casing of the TD 03 and accessible via t...

Page 21: ...oncerning control and responds to the application processing of the PLC according to the engineered presetting With concerning project engineering you may monitor res alter process values via the disp...

Page 22: ...the TD 03 You may import the data block in the SIMATIC Manager from Siemens into your project and load it to the CPU After the link up of the TD 03 with valid MPI parameters the according DB contents...

Page 23: ...quests in a configurable language and the according character set The here chosen language has no influence on the text of the user defined message texts that are displayed by the TD 03 At the moment...

Page 24: ...s outputs via the TD 03 i e freeze them at a defined state Forcing takes place at the beginning and at the end of a cycle During the cycle forcing is deactivated If you activate the password protectio...

Page 25: ...ten the TD 03 calls the CPU with a message request The setting of bit memory bytes with function keys is not influenced During operation the behavior of the function keys may be selected within the Me...

Page 26: ...messages simultaneously A 20 character message uses 20Byte in the data block of the CPU Every message is shown in one row of the TD 03 That allows to display two messages at one time A 40 character me...

Page 27: ...s to set an according release bit in your DB Here you define the start address from where on the release bytes are stored in your DB default value 12 Set the start address the messages are stored in s...

Page 28: ...between the insert and the overwrite mode by means of the PC key Einfg Ins The recent mode INS res OVR is shown in the dialog window Via you may enter the next message For the inclusion of process dat...

Page 29: ...ed unsigned or as real number with decimals Real By choosing the positions right of the decimal sign value of an integer can be scaled for the display At a real number you define the number of digits...

Page 30: ...of the decimal sign 2 to 7 two to seven digits right of the decimal sign Bit 3 0 Bit 6 4 S Data size Format 0 no data value 1 word value signed 2 double word value signed 3 word value unsigned 4 doubl...

Page 31: ...external power supply the sticker with the safety information is to be removed before The wiring takes place with spring clamp technology The cabling with spring clamp technique enables a fast and eas...

Page 32: ...aud rate DB no and so on are to be set in the Menu mode By pushing the key in the display mode you reach the Menu mode Navigate at Menu mode with to the entry Terminal Setup and confirm with Set with...

Page 33: ...back to display mode In display mode the cursor entry sign faded out It appears by pushing res To navigate through the menu the following keys are available res jumps to the previous res next menu ent...

Page 34: ...option Activate the according menu option with If the menu item is a variable brings you into the alteration mode This is shown with a blinking of the variable Now you may alter the value with and and...

Page 35: ...r the TD 03 receives its data from a CPU data block you may store several data blocks in the CPU Via the entry Parameter Block you define the wanted DB via its number Navigate on with until you reach...

Page 36: ...y available if enabled in the TD Wizard You may also protect this function with a password Force I O allows you to set in res outputs to a fixed value During the cycle the values may be overwritten by...

Page 37: ...the TD Wizard You activate the password request at value entering during the project engineering of your messages by opening the according dialog via If you ve activated the password protection in the...

Page 38: ...following settings Internet Explorer ftp access ability since V 5 5 Options Internet options register extended in the area Browsing activate Activate directory view for ftp sites activate Use passive...

Page 39: ...r TD 03 is now prepared for data transfer to 6 A click on opens a file selection window Choose the according firmware and start the download with If the error message The selected file doesn t fit to...

Page 40: ...Chapter 2 Deployment TD 03 Manual VIPA HMI 2 24 HB116E TD03 Rev 07 50...

Page 41: ...omagnetic compatibility EMC and how to approach shielding and screening issues The following text describes EMC and possible interference sources Basic rules for ensuring EMC EMC orientated assembly a...

Page 42: ...r applications in harsh industrial environments and complies with EMC requirements to a large degree In spite of this you should implement an EMC strategy before installing any components which should...

Page 43: ...o the time characteristics of the voltage Interference through parallel signal lines Static discharge of the personnel Contactors Inductive coupling Automation System Disruptor inductive coupling line...

Page 44: ...roups High voltage lines power supply lines signal lines data lines Always install high voltage lines and signal or data lines in separate channels or bundles Install signal and data lines as close as...

Page 45: ...lamps Create a single reference potential and ensure that all electrical equipment is grounded wherever possible Ensure that grounding measures are implemented effectively The controllers are grounded...

Page 46: ...ay only get voltage in case of an error The ground must not adopt dangerous contact voltage even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid gro...

Page 47: ...o divide the cables in different groups and install each group itself Group A screened bus and data lines screened analog lines unshielded lines for direct voltage 60V unshielded lines for alternating...

Page 48: ...e installed on metallic cable trays A galvanic connection must be provided for joints between cable trays You must abide by the applicable lightning protection and grounding regulations when installin...

Page 49: ...m 2 Cu for equipotential bonding conductors up to 200m 25mm2 Cu for equipotential bonding conductors exceeding 200m Use copper or galvanized steel for equipotential bonding conductors These must be co...

Page 50: ...recommended that the remove the insulation from the screened cable without cutting the screen and to attach this point to the screening neutral rail Note Potential differences may give rise to an equa...

Page 51: ...f DC activated inductors Connections of AC activated inductors using a diode using a Z diode using a varistor using RC network Every cubicle must be provided with a power outlet for the PGs These outl...

Page 52: ...al contact washer Have the connection been protected from corrosion e g by means of grease Have doors been grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabl...

Page 53: ...word 2 14 Function keys 2 9 Mode 2 19 H Hardware description 1 1 I Installation 2 4 Installation guidelines 3 1 K Keyboard 1 6 2 17 L LCD 1 6 M Menu mode 2 18 Messages 2 10 2 12 Address 2 11 Create 2...

Page 54: ...Index Manual VIPA HMI A 2 HB116E TD03 Rev 07 50 M Stich...

Reviews: