Appendix A - System Reference
106
7700 Series Flash Storage Platform Installation Guide 7.6.3.x
530-0267-00 Rev 02
2.
Verify that each storage pool has a unique name, a correct ACSL, and an owner for each
device (shown in red text in the example above).
Note:
Due to brevity, only two devices are shown in the previous example.
Rescanning all Memory Gateway Devices
Complete the steps in this section to ensure that both Memory Gateways are able to see the state
of all devices assigned to the other Memory Gateway, and it is important that no devices should be
unassigned
.
IMPORTANT
: Complete the following steps on both Memory Gateways.
1.
Issue the following command to inspect the devices and view each device’s Category:
Device Name: BKSC:OTHDISK-MFCN06.001
ACSL: 98:0:3:1 red
Total Sectors: 2147469312
Sector Size: 512
Size: 1048568MB
Category: Virtual Device
Owner: hostname-mg-a
Guid: 5c90e836-7b24-7ee7-2afe-000054c9597b
State: Online
Device Name: BKSC:OTHDISK-MFCN0D.000
ACSL: 98:0:4:0
Total Sectors: 2147469312
Sector Size: 512
Size: 1048568MB
Category: Virtual Device
Owner: hostname-mg-a
Guid: 67706a81-1d59-3eea-31e6-000054c95985
State: Online
.
.
.
Command: getstoragepools executed successfully.
[root@hostname-MG-A ~]#