- 51 -
Start
– the start time of this time segment, increment at 30 minutes. (The end
time of this time segment is implicitly set as the start time of next time segment,
or the start time of the first time segment of the same weekday if it’s the last one.)
Press
+/-
buttons to select the desired start time.
Example: If the user sets the start time of T1/MON as 9:00, T2/MON as 18:00,
T3-T16/MON as N/A (Not Available), then T1/MON is 9:00-18:00,
T2/MON is 0:00-9:00, and 18:00-24:00.
Alarm
– record mode (No, Video, Audio/Video) when certain alarm input is
triggered.
“OFF” is newly added for alarm detection OFF.
Press
+/-
buttons to
change the value.
Motion
– record mode (No, Video, or Audio/Video) when motion is detected for
certain camera.
“OFF” is newly added for motion detection OFF.
Press
+/-
buttons to change the value.
Normal
– normal record mode, including No, V (Video only), or A/V
(Audio/Video). Press
+/-
buttons to change the value.
Note: In a time segment, if both Alarm and Motion are set to “OFF”, the audio/video
will be treated as Normal unless there’s Video Loss.
Scheduled Record – Easy Setup
The Scheduled Record – Easy Setup allows the administrator to use a simpler and
easier way to setup the scheduled record of the system. In Easy Setup, there are
Six
Selectable
Recording Modes:
Alarm+Normal
,
Alarm+Motion
,
Alarm
,