7

DEFROSTING/CONDENSATION/ HYGROMETRY/ VENTILATION 

 
Your beverage center is designed with “Auto-cycle” defrost system. During “Off-cycle” 
the refrigerated surfaces of the beverage center defrost automatically. Defrost water from 
the beverage center storage compartment drains automatically and part of it goes into a 
drainage container, which is located at the back of the beverage center next to the 
compressor. The heat is transferred from the compressor and evaporates any condensation 
that has collected in the pan. Part of the remaining water is collected within the beverage 
center for humidity purposes. 
This system enables the creation of the correct humidity level inside your beverage center 
required by the natural cork to maintain a long lasting seal. 
 

Notes:

 

The water collected by condensation, is therefore recycled. Under extremely dry 

environmental conditions, you may have to add some water into the water container 
provided with your beverage center. 

All units are equipped with a double glazed glass door that has a third internal acrylic 
layer to minimize condensation on the glass door. 
 
The beverage center is not totally sealed; fresh air admission is permitted through the 
drainpipe.  Air is circulated through the uint by means of a fan/fans and the hollow 
shelves. 
 

Notes:

 

During the refrigerating cycle, heat is given off and disperse through the external 

surfaces of the beverage center. Avoid touching the surfaces during those cycles. 
 
 
ADJUSTABLE SHELVES 
 
Adjusting/removing the shelves 

When removing any of these shelves out of the rail compartment, To fit or remove the 

shelf, tilt the shelf as per the diagram and simply pull out, or push in the shelf until it sits 
on the support brackets securely. 

 

 

Summary of Contents for 40BVC

Page 1: ...Armoire vin Beverage Preservation Technology USER MANUAL 40BVC AL V40BVC...

Page 2: ...e R600A WARNINGS The following models use small quantity of R600A iso butane flammable refrigerant in their sealed system as follow AL V40BVC 35g For your safety observe the following recommendations...

Page 3: ...safe recycling DO NOT dispose of the appliance in land fill as the insulation and refrigerant gas contained in these appliances are flammable Allow 24 hours before switching on the Beverage Center Du...

Page 4: ...service person if the grounding instructions are not completely understood If the supply cord is damaged it must be replace by a qualified person in order to avoid electrical hazard Installing your Be...

Page 5: ...e Beverage Center after having it shut off for a long time there will be a few degrees variance between the temperature you have selected and the one indicated on the LED readout This is normal and it...

Page 6: ...of the following if you do not have enough bottles to fill your Beverage Center it is better to distribute the load throughout the Beverage Center so as to avoid all on top or all below type loads Do...

Page 7: ...the actual temperature of the Beverage You will need to wait approximately 12 hours before noticing the effects of temperature adjustment due to the critical mass within a full Beverage Center Once th...

Page 8: ...l Notes The water collected by condensation is therefore recycled Under extremely dry environmental conditions you may have to add some water into the water container provided with your beverage cente...

Page 9: ...Top hinge Right 4 Lock Screws 5 Top hinge Left 6 Lower hinge Left 7 Door While holding the door firmly remove the three lock screws 2 from the lower right hinge module and remove it Fig 1 Remove the...

Page 10: ...draws air from the rear and expels through the metal grid under the door at the front If a kick board is to be placed in front of the ventilation grid another grill must be fitted into the kick board...

Page 11: ...non technician will lead to the warranty being considered as null and void POWER FAILURES In the event of a power interruption all previous temperature settings are automatically erased and it will re...

Page 12: ...ge center The door is opened too often The door is not closed completely The temperature control is not set correctly The door gasket does not seal properly The light does not work Not plugged in The...

Page 13: ...kg REFRIGERANT R134a R600a 0 Units with no heater will not raise its internal temperature if the ambient temperature where the unit is located is lower than the set temperature 1 Subject to changes a...

Page 14: ...Copyright All rights are reserved All photocopying reproduction translation whether partial or total are strictly prohibited without prior written consent from VINTEC www vintec cellar com...