Vintage Air 491241 Manual Download Page 4

4

www.vintageair.com

901441 REV B 1/30/19, PG 4 OF 9

Control Panel Dimensions

Control Panel Installation

Select a suitable location for the control panel, considering heater control valve location, wiring harness

length and operator convenience.
After selecting a location for the control panel, mask the area 1 ½” (tall) x 4 ½” (wide).
Using the dimensions provided above, mark or scribe the control panel opening location onto the dash.

When you are certain that the dimensions and markings are correct, cut the dash to make the control

panel opening. 

NOTE: Measure twice. Cut once. This opening MUST be a precise fit. Cut the opening

undersize, and then file to fit. The mounting screws only hold the panel against the dash. They do

not locate the panel laterally. If the opening is oversized, the panel may shift during use.
Install the control panel face through the opening in the dash. Place the control panel PC board assembly

behind the dash, and secure it to the control panel face using the (4) 8-32 x 3/8” screws (See Figure 1 and

2a, Page 5). NOTE: When tightening the control panel mounting screws, hand tighten until the

screw contacts the back side of the dash. Then, using a screwdriver, tighten an additional 1/2

turn. Do not overtighten, as this may cause damage to the PC board or the dash.
Install the control panel knobs (See Figure 1, Page 5).
Plug the control panel wiring harness into the control panel and the ECU on the evaporator (See Figure 2,

Page 5).
Wire according to the wiring diagram on Page 7.

1.

2.
3.

4.

5.
6.

7.

3.3175”

1.440”

Ø.3438 (11/32)”

Ø.4375 (7/16)”

NOTE: Do not install the (2) control panel knobs onto the control panel assembly until the panel has 

been installed in the dash. For knob removal after installation, refer to the Control Panel Removal 

instructions on Page 6. DO NOT attempt to remove the knobs using pliers.

2.880”

Level This Line

1.0438”

.700”

Summary of Contents for 491241

Page 1: ...pany Streamline Gen IV ProLine Ellipse Panel Black Anodized 491241 901441 REV B 1 30 19 PG 1 OF 9 18865 Goll St San Antonio TX 78266 Phone 800 862 6658 Sales sales vintageair com Tech Support tech vin...

Page 2: ...unning the engine with the heater on before evacuating Leak check and charge to specifications The Proper Amount of Refrigerant is Critical to Proper System Operation Vintage Air Recommends Our System...

Page 3: ...amline Gen IV ProLine Ellipse Before beginning installation open all packages and check contents of shipment Please report any shortages directly to Vintage Air within 15 days After 15 days Vintage Ai...

Page 4: ...control panel face through the opening in the dash Place the control panel PC board assembly behind the dash and secure it to the control panel face using the 4 8 32 x 3 8 screws See Figure 1 and 2a P...

Page 5: ...Panel PC Board Assembly Rear View Side View Thread Into Back Side of Control Panel Face Opening in Dash ECU 232007 VUR Gen IV Universal Control Harness Control Panel Face Snug Against Back Side of Das...

Page 6: ...rol panel face See Figure 3 below Hold the PC board assembly and pull it away from the dash until the board comes loose from the control panel face See Figure 4 below NOTE The control panel knobs will...

Page 7: ...VUR 232002 VUA CIRCUIT BREAKER 30 AMP WIDE OPEN THROTTLE SWITCH OPTIONAL DASH LAMP IF USED Dash Lamp Is Used Only With Type 232007 VUR Harness Warning Always Mount Circuit Breaker As Close to the Batt...

Page 8: ...emperature lever knob all the way to cold and then back it off to the desired vent temperature For heat operation move the temperature lever knob all the way to hot and then adjust to the desired vent...

Page 9: ......

Page 10: ...9 www vintageair com 901441 REV B 1 30 19 PG 9 OF 9 Packing List Control Panel Kit 491241 No 1 Qty 1 Part No 491241 Description Streamline Gen IV ProLine Ellipse Checked By Packed By Date 1...

Reviews: