- 4 -
Fig. 1.2 DIMENSIONS (in)
The specifications and dimensions are listed as follows:
Model
Exhaust CFM
Cabinet Size
(cu ft)
Electrical
Weight(lb)
WM-1500cd
Rear Exhaust
120
90
115V/60Hz/4A
50
WM-
1500cted
Top Exhaust
120
90
115V/60Hz/4A 50
WM-2500cd
Rear Exhaust
180
200
115V/60Hz/5A
55
WM-
2500cted
Top Exhaust
180
200
115V/60Hz/5A 55
NOTES:
•
Also see the voltage, frequency and current specified on the label at the
cooling unit.
•
The rated capacity is determined under the cabinet and ambient
temperatures of 55
°
F and 75
°
F with R13 interior and R19 exterior
insulations. Any lower cabinet temperature, higher ambient temperature
and less insulation will cause reducing capacity and may not maintain
55
°
F.
•
The ambient temperatures for WM-1500CD shall not be higher than 78
°
F
or lower than 50
°
F in order to operate properly.
•
The ambient temperatures for WM-2500CD shall not be higher than 95
°
F
or lower than 50
°
F in order to operate properly.