Vingtor Stentofon VSP-211M-L User Manual Download Page 3

Station Operation

To make a call to another station:
1.  Set the extension number (00 - 19) of the station you 

wish to call:

 

Select the first digit by setting the 

Group

 switch to 

either 0 or 1.

 

Select the second digit by setting the rotary switch (

Line 

Selector

) to numbers from 0 to 9 (numbers 10 and 11 

are blocked).

 

Example: to make a call to extension number 15, set the 

Group

 switch to 1 and the rotary switch to 5.

2.  Turn the crank clockwise until a loud beeping tone is 

heard from the station.

 

About 5 to 6 turns will be required.

3.  Lift the handset, press the button on the handset and 

keep it pressed during the entire conversation.

you may now converse with full power and without distortion 
for a guaranteed period of 20 minutes. 

Troubleshooting

Problem 1

The VSP-M station does not receive calls. There is no signal tone. 
The issue could be that no extension number is set. 

Possible solution: 

 

Verify that the station has the correct address for the extenstion 
number set on the DIP switches (see Figure 1). 

Problem 2

VSP station receives calls from both groups.

Possible solutions: 

 

Verify that only DIP switch 11 for GROUP 0 or only DIP 

switch 12 for GROUP 1 are set to the ON position.

 

Remove jumpers from pins J2 and J3. 

Problem 3

When mounting sparepart board, no call tone is heard.

Possible solution:

When using boards with inductors, remove jumpers from pins J6 
and J7/J8 and insert a jumper on pin J9 located to the left of the DIP 
switches.

F

igure 3: Group and Line Selector