On-Wall Surface Mounting

2.1  On-Wall Surface Mount Back Box - TA-1

2.2  On-Wall Surface Mounting Procedure

1.  Mount the back box onto the wall
2.  Fit the gasket onto the back box with the ridged side facing down

 

Plug the AlphaCom cable into the RJ-45 port on the station

3.  Mount the Turbine station onto the back box with the M5 fasteners provided applying 

1.5 Nm torque

76 mm

150 mm

D6.5 mm

25 mm

120 mm

Mounting holes are to be drilled 

as shown.
Max. recommended screw 

diameter: ISO M6 or ANSI 1/4".

Screw length must be greater 

than 25 mm or 1".

 

A4 stainless steel socket head 

screws/bolts are recommended.

Max. recommended screw

head diameter: 9.5 mm or 3/8".

3”

5.90”

4.72”

1”

0.25”

D

Mounting Hole

Mounting Hole

Mounting Hole

Mounting Hole

Optional washers for extra protection

against corrosive effects between

surfaces are provided. 

They should be placed at the bottom 

of the 4 mounting holes.

Grommets and an M20 cable gland 

are provided.

cable holes

M20

M16

Surface

Mount 

Back Box

Gasket

1

2

Microphone

Washers

Turbine

Station

3

 

L

The Gasket MUST be mounted to 

seal the station!

 

L

Ensure the station is mounted verti-

cally with the microphone aperture 

facing down.

 

L

Ensure there is enough clearance 

under the station so that the micro-

phone aperture is NOT smothered.

 

L

Place the washers at the bottom of 

the 4 mounting holes on the back 

box.

 

L

Use the grommets and M20 cable 

gland provided for the cable holes 

on the back box.

 

L

IP-66 rating is only valid when 

TA-1 Back Box is used