Electrical Connections

Mounting Cable Gland

 

Remove two blind plugs and insert one 

M16 Ex e and one M25 Ex e cable gland. 

Make sure to tighten sufficiently to attain 

IP-66 rating for watertightness, but be 

aware of plastic material limitations.

For complete documentation, see 

Installation & 

Maintenance Procedures for Exigo Ex Access 

Panels & Turbine Ex Intercoms

, Doc. no. 

A100K11499. 

Related Documentation

Document No.

Documentation

A100K11499

Exigo & Turbine Ex Installation & Maintenance Procedures

A100K11460

Exigo Technical Manual

A100K11422

Flowire Installation & Configuration Manual

A100K11471

Exigo User Manual

A100K11194

Turbine Stations Configuration Manual

Accessories & Spare Parts

Item Number

Item Name

Item Description

AK5850HS

AK5850HS

Ex-Approved Headset with plug

1008150025

TAX-2B

Ex-Approved Cable for Headset with PTT Button

1008150030

TAX-3

Ex-Approved Handset with PTT, unterminated

1023533511

EMMAX-1H

Exigo Handheld Industrial Ex Microphone

1000150040

TAX-4

Cable gland kit (10x) for TFIX and EAPFX

1023594100

EGA-1

Button Protection Covers (10x)

1008140250

TA-25

M6 screw kit

  

In order to ensure the required minimum degree of protection, 

the cable glands must be tightened securely. 

  Over-tightening can impair the degree of protection and 

damage the Ex unit. 

    When tightening the cap nut of a cable gland, a suitable tool 

shall be used to prevent the gland from twisting.
If there is an X sign after the Ex certificate number, this indi-

cates that the equipment is subject to special conditions for 

safe use.

Special conditions for safe use:

 

The cable glands shipped with this product have an impact  

resistance of maximum 4J. Due to low impact resistance of the cable 

glands, the units shall only be installed in areas where there is a low 

risk of impact. 

If cable glands supporting high impact (7J) are used, the X 

conditions do not apply.

PRESAFE

14ATEX5209X

IECEX

PRE 14.0029X

Approved

EB / 18.02.2015

A100K11523

The relevant certificates and declarations of conformity may be 

downloaded from www.zenitel.com/customer-service/library

Summary of Contents for 1008123010

Page 1: ...ccess Panels Turbine Ex Intercoms Mounting manual Station overview Installation procedures are the same for all panels in the Industrial Ex series Contents of this delivery Note The unit are equipped with four blind plugs front frame is fastened with 2 unbraco M6 screws Important notes before mounting Improper installation and operation of the Ex access panel will result in the invalidation of the...

Page 2: ...ling the front frame out 5 mm keeping it parallel to the on wall box This is necessary to get clearing for the hinges 3 Pull the right side of the front frame to open the enclosure fully Do NOT open the enclosure to the extent that cables between the front and back parts become taut Opening the Enclosure ...

Page 3: ...t the 4 screw holes in each corner of the on wall box Ø6 4 mm Use Panhead DIN7981 screw for plug or wooden wall Head Ø 10 8 B5 5 x 38 or 45 mm 6 Mounting Plate or Column Fix the unit to the mounting plate or column with 4 screws that fit the 4 screw holes in each corner of the on wall box Ø6 4 mm Use M5 x 20 or 25 with Philips head DIN7985 or Torx Head Ø 10 mm 5 Location Make sure there is a clear...

Page 4: ...hnical Manual A100K11422 Flowire Installation Configuration Manual A100K11471 Exigo User Manual A100K11194 Turbine Stations Configuration Manual Accessories Spare Parts Item Number Item Name Item Description AK5850HS AK5850HS Ex Approved Headset with plug 1008150025 TAX 2B Ex Approved Cable for Headset with PTT Button 1008150030 TAX 3 Ex Approved Handset with PTT unterminated 1023533511 EMMAX 1H E...

Reviews: