Electrical Connections
8
Mounting Cable Gland
Remove two blind plugs and insert one
M16 Ex e and one M25 Ex e cable gland.
Make sure to tighten sufficiently to attain
IP-66 rating for watertightness, but be
aware of plastic material limitations.
For complete documentation, see
Installation &
Maintenance Procedures for Exigo Ex Access
Panels & Turbine Ex Intercoms
, Doc. no.
A100K11499.
Related Documentation
Document No.
Documentation
A100K11499
Exigo & Turbine Ex Installation & Maintenance Procedures
A100K11460
Exigo Technical Manual
A100K11422
Flowire Installation & Configuration Manual
A100K11471
Exigo User Manual
A100K11194
Turbine Stations Configuration Manual
Accessories & Spare Parts
Item Number
Item Name
Item Description
AK5850HS
AK5850HS
Ex-Approved Headset with plug
1008150025
TAX-2B
Ex-Approved Cable for Headset with PTT Button
1008150030
TAX-3
Ex-Approved Handset with PTT, unterminated
1023533511
EMMAX-1H
Exigo Handheld Industrial Ex Microphone
1000150040
TAX-4
Cable gland kit (10x) for TFIX and EAPFX
1023594100
EGA-1
Button Protection Covers (10x)
1008140250
TA-25
M6 screw kit
In order to ensure the required minimum degree of protection,
the cable glands must be tightened securely.
Over-tightening can impair the degree of protection and
damage the Ex unit.
When tightening the cap nut of a cable gland, a suitable tool
shall be used to prevent the gland from twisting.
If there is an X sign after the Ex certificate number, this indi-
cates that the equipment is subject to special conditions for
safe use.
Special conditions for safe use:
The cable glands shipped with this product have an impact
resistance of maximum 4J. Due to low impact resistance of the cable
glands, the units shall only be installed in areas where there is a low
risk of impact.
If cable glands supporting high impact (7J) are used, the X
conditions do not apply.
PRESAFE
14ATEX5209X
IECEX
PRE 14.0029X
Approved
EB / 18.02.2015
A100K11523
The relevant certificates and declarations of conformity may be
downloaded from www.zenitel.com/customer-service/library