background image

50

90716577.L.E  19-09-2003  8:49  Pagina 50

Summary of Contents for Idea 16577

Page 1: ...MA LU ME GI VE SA DO ON 0 4 8 12 16 20 T3 T2 T1 ...

Page 2: ...3 Electronic chronothermostat for the ambient air temperature control 90716577 L E 19 09 2003 8 49 Pagina 3 ...

Page 3: ... the assigned value can also be set between 0 1 C and 0 9 C The chronothermostat is supplied through 3 1 5 V LR03 AAA alkaline batteries not delivered lasting approximately 1 year A 2 minutes power reserve is granted to allow the batteries replacement without losing the set regulations Index 1 Description 5 2 Data display and external controls 6 3 Internal controls 8 4 Setting the present time and...

Page 4: ...ent 14 Decrease temperature hour day etc 15 Increase temperature hour day etc 16 Multifunction 17 Exclusion of the installation 6 2 Data display and external controls Data display 1 Time scale of the daily program diagram The blinking point in the diagram matches the time displayed 2 Temperature levels 3 Digital thermometer 4 Digital clock MA LU ME GI VE SA DO ON 0 4 8 12 16 20 T3 T2 T1 1 17 5 4 3...

Page 5: ... the equipment by both sides picture 3 1 and take it out to the stop picture 3 1 To insert the equipment again press the two side lugs 1 on the symbol and push it thoroughly 2 until it comes to the stop picture 3 2 2 1 1 picture 3 2 90716577 L E 19 09 2003 8 49 Pagina 8 ...

Page 6: ...T1 T2 T3 Setting the hysteresis the maximum gap between the ambient air temperature and the assigned value 21 Selection of the HEATING or AIR CONDITIONING program 22 Time decrease on the daily program diagram 23 Time increase on the daily program diagram 24 Selection of the day of the week 25 Copy of the program 90716577 L E 19 09 2003 8 49 Pagina 10 ...

Page 7: ...Press the pushbutton or to set the hour value 13 MA LU 0 4 8 16 20 ME GI VE SA DO ON T3 T2 T1 12 MA LU 0 4 8 16 20 ME GI VE SA DO ON T3 T2 T1 12 4 3 Press the pushbutton the indicator of the day of the week blinks Press the pushbutton or to set the day of the week 4 4 To end the operation press the pushbuttone the two points between the hour and the minutes figures blink 60 seconds after the last ...

Page 8: ...elect the desired program press the pushbutton 5 1 HEATING Program The HEATING program provides two different daily thermic cycles one from Monday to Friday picture 5 1 1 and one for Saturday and Sunday picture 5 1 2 15 MA LU ME GI VE SA DO ON 0 4 8 12 16 20 T3 T2 T1 5 1 1 HEATING program thermic cycle from Monday to Friday Temperature levels T1 16 C T2 18 C T3 20 C 5 1 2 HEATING program thermic c...

Page 9: ...til a new temperature or a new operating mode is selected The ambient air temperature will be displayed about 5 seconds after the last setting To verify at any moment the set temperature value press twice the pushbutton 16 5 2 AIR CONDITIONING program The AIR CONDITIONING program provides a single thermic cycle for the whole week MA LU ME GI VE SA DO ON 0 4 8 12 16 20 T3 T2 T1 5 2 1 AIR CONDITIONI...

Page 10: ...ature see paragraph 6 18 7 1 1 Press once the pushbutton h01 is displayed Set the desired number of hours pressing the pushbutton or from 1 to 99 hours Note The hour in which the setting is done is included in the countdown and is considered a whole hour 7 TIME DELAY MANUAL operation If you wish to keep the manual temperature for a certain time hours or days you can use the TIME DELAY MANUAL opera...

Page 11: ...35 C Example If the level of T1 corresponds to 15 C and the level of T3 to 22 C the level of T2 can be varied from 15 1 C to 21 9 C 8 1 2 Press the pushbutton the range of temperatures of T1 and the temperature value to be changed are displayed Set the desired temperature value pressing the pushbutton or Press the pushbutton to confirm the operation and to proceed with the next temperature value 2...

Page 12: ...ONING program 23 8 2 2 Press the pushbutton the range of temperatures of T1 and the temperature value to be changed are displayed Set the desired temperature value pressing the pushbutton or Press the pushbutton to confirm the operation and to proceed with the next temperature value To change the value of T2 and T3 repeat the instructions indicated in paragraph 8 2 2 At the end of the settings of ...

Page 13: ...m 24 9 Own setting of the DAILY PROGRAM Take out the body of the equipment MA LU ME GI VE SA DO ON T3 T2 T1 0 4 8 12 16 20 MA LU 0 4 8 12 16 20 ME GI VE SA DO ON T3 T2 T1 9 1 Press the pushbutton and put the day indicator of the display on the LU position Monday 25 MA LU 0 4 8 12 16 20 ME GI VE SA DO ON T3 T2 T1 9 3 Select the desired temperature level pressing the pushbutton or MA LU 0 4 8 12 16 ...

Page 14: ...et program is also suitable for the next days press the pushbutton 27 MA LU 0 4 8 12 16 20 ME GI VE SA DO ON T3 T2 T1 9 7 At the end of the settings press the pushbutton the present time and day will be displayed About 10 seconds after the last setting the equipment automatically ends the operation storing all the settings Insert again the body of the equipment Note At any moment it is possible to...

Page 15: ...t for the desired day 28 10 JOLLY Program The equipment is provided with a JOLLY program suitable for holidays or festivities during the week etc This program can be started at any moment of the day and kept in operation till the end of that day or else it can be scheduled for any day of the week The preset thermic cycle is the cycle provided for Saturday and Sunday see paragraph 5 but it is also ...

Page 16: ...ive under a security level MA LU 0 4 8 12 16 20 ME GI VE SA DO ON T3 T2 T1 30 Proceed if you wish with the own setting of the Jolly program as indicated in paragraphs 8 and 9 excluding 9 5 and 9 6 MA LU 0 4 8 12 16 20 ME GI VE SA DO ON T3 T2 T1 10 3 Press the pushbutton to restore the AUTOMATIC operating mode The JOLLY program will start at 0 o clock of the selected day The JOLLY program may be ca...

Page 17: ...ature see paragraph 11 32 12 1 1 Press once the pushbutton h01 is displayed Set the desired number of hours pressing the pushbutton or from 1 to 99 hours Note The hour in which the setting is done is included in the countdown and is considered a whole hour 12 TIME DELAY ANTIFREEZE operation The time delay antifreeze operation is used to maintain a safety temperature for a certain time hours or day...

Page 18: ...ake out the body of the equipment Press the pushbutton the installation working time is displayed for about 5 seconds 35 13 2 To reset the timer and start a new count press the pushbutton while the figures of the installation working time are still displayed Insert again the body of the equipment MA LU ME GI VE SA DO ON T3 T2 T1 0 4 8 12 16 20 14 Display of the temperature levels Take out the body...

Page 19: ...n The chronothermostat can also be used only as a thermometer and a clock excluding any control on the heating or on the air conditioning installation This operating mode is particularly useful in case the equipment is not in use for a long period in case of maintenance or of a long absence etc 15 1 Exclusion of the installation during the HEATING program MA LU 0 4 8 12 16 20 ME GI VE SA DO ON T3 ...

Page 20: ...countdown and after that the AUTOMATIC operating mode is restored 16 1 Time delay exclusion of the HEATING PROGRAM Exclude the heating installation as indicated in paragraph 15 1 16 1 1 Programming by hours 39 15 2 1 Press once the pushbutton instead of the daily program diagram the indicator under the symbol is displayed confirming the exclusion of the temperature control The ambient air temperat...

Page 21: ...by hours and or in paragraph 16 1 2 programming by days 40 16 1 2 1 Press twice the pushbutton d01 is displayed Set the desired number of days pressing the pushbuttons or from 1 to 99 days Note The day in which the setting is done is included in the countdown and is considered a whole day 16 1 1 2 Press the pushbutton or to restore the AUTOMATIC operating mode before the end of the countdown MA LU...

Page 22: ...t the body of the equipment MA LU 0 4 8 12 16 20 ME GI VE SA DO ON T3 T2 T1 17 1 Press the pushbutton and at the same time the pushbutton Stop first the pressure on the pushbutton and after the pushbutton Insert again the body of the equipment MA LU 0 4 8 12 16 20 ME GI VE SA DO ON T3 T2 T1 17 Cancellation of the own programs If you wish to restore the equipment to its starting set of data and pro...

Page 23: ...on or to set the desired value To end the operation press the pushbutton or wait about 10 seconds then insert again the body of the equipment 19 Hysteresis The hysteresis the maximum gap between the ambient air temperature and the assigned value can be set between 0 1 C and 0 9 C The equipment is delivered with a factory preset hysteresis of 0 2 C suitable for high inertia equipments as for instan...

Page 24: ... again picture 20 2 46 Press the two sides lugs 1 on the symbol and take the body of the equipment completely out 2 picture 20 2 2 1 1 47 Insert again the body of the equipment ATTENTION An incorrect insertion of the batteries will seriously damage the equipment The time to replace the batteries is about 2 minutes after which the clock setting is lost and the count of the installation working time...

Page 25: ...3 temperature levels programmable from 2 C to 35 C with the possibility of assigning a different temperature level to each hour every day of the week Antifreeze temperature programmable between 2 C and 35 C Ambient air temperature detection every 15 seconds Hysteresis programmable from 0 1 C to 0 9 C Reading resolution 0 1 C Precision 0 3 C Liquid crystals data display Installation working timer f...

Page 26: ...50 90716577 L E 19 09 2003 8 49 Pagina 50 ...