Configuration procedure ("Standard” Mode):
• Press and hold down the
key
• Press the
key too and hold them down until the
key starts flashing.
• Release the keys.
• Press and hold down the key you wish to configure (
1 / 2 / 3 / 4
).
• Wait for the indoor station to emit an audible warning.
• Release the key.
• Call the indoor station from the outdoor station you want to perform a direct self-start:
- On entrance panels with keys, press the key corresponding to the indoor station on which the key is being configured.
- On alphanumeric entrance panels, enter the ID corresponding to the indoor station on which the key is being configured and
confirm with the call key.
• At the end of the procedure described above, the indoor station emits a signal to confirm that the operation has been successful
and it is called by the outdoor station.
Configuration of a key for self-start of a specific outdoor station ( , , , ,
)
Configuration procedure ("Simplified” Mode):
1. Press the key to be programmed and hold it down for at least 6 s.
2. When the indoor station has emitted a “beep”, release the key being programmed.
3. From the outdoor station concerned, within 60s, make a call to the indoor station being programmed.
4. A high tone confirms the end of the procedure. The indoor station will be called by the outdoor station concerned.
3
4
1
> 6s
beep
beep
2
< 60 s
N.B. (*): for entrance panels with push buttons press the call button corresponding to the indoor station, for alphanumerical entrance
panels, type in the ID code and confirm with the call key.