3.2 - Description of the input functions
51
Step by step (N.O.):
Sequential control input, to control the full gate travel.
Operating according to the setting for parameters P39 and P03:
P39 = 0, P39 = 1 input 51 operating according to parameter P03.
P39 = 2 input 51 only controls the opening.
P03 = 1 collective, input 51
- not active in opening
- in pause it reloads the pause time if automatic closing is active and suspends the pause if the input remains engaged (for connecting coils
or a timer), re-closes if automatic closing is not active
- in closing it re-opens.
P03 = 2 sequential Opens, Stop, Closes, Stop, Opens.
P03 = 3 sequential Opens, Closes, Opens
52
Pedestrian (N.O.):
Control input to open the gate for pedestrians as input 51 but at pedestrian distance
61
Stop (N.C.):
Stops the gate.
If not used, jumper with the common (99)
62
Closing photocell - PHC (N.C.):
If not used, jumper with the common (99)
63
Photocell - PH (N.C.):
Operating according to the setting for parameter P06:
P06 = 1 Photocell:
- with the gate stopped, does not allow the gate to open
- during opening stops the movement and when released proceeds with opening
- with the gate open, does not allow closing and when released will reload the pause time
- in closing stops the movement and when released reopens the gate
P06 = 2 Sensitive edge with NC clean contact:
- with the gate stopped, does not allow the gate to open
- in opening disengages, re-closes after the pause time if automatic closing is active
- with the gate open, does not allow closing and when released will reload the pause time
- in closing disengages and opens
P06 = 3 8.2 KΩ balanced sensitive edge (8K2)
Same behaviour as the NC sensitive edge
If not used, jumper with the common (99) and set P06 = 1
4 - Connecting accessories
4.1 - Key switch and control devices
EDS1
Step-by-step control
Pedestrian control
99
52
63
51
99 61 62
COM
COM
N.O.
N.O.
N.C. N.C.
PED
COM
P.
P.