Viale Vicenza, 14 - I 36063 Marostica VI
Tel. +39 0424 488 600 - Fax (Italia) +39 0424 488 188 - Fax (Export) +39 0424 488 709
www.vimar.eu
Instruction sheet
E-way
02741-02742-02743-02744-02745-02746-02749-02750-02753-02754-02759-02760
CONNECTIONS.
OPERATION.
• The lamp provides auxiliary lighting in the event of a mains power failure.
• When the mains power returns the lamp will automatically switch off and the green LED will switch on.
• Battery charging takes place continuously when there is mains voltage.
LED SIGNALLING
.
Green Led flashing
= Fast charge
Green Led continuous
= Normal charge
Yellow Led Off
= Normal operation of the emergency lamp
Yellow Led On
= Emergency lamp in the inibition mode
USE
.
• Permanent (
SA
): the lamp is always on (typical used for indicator lighting).
• Non-Permanent (
SE
): the lamp only switches on when there is a mains power cut (typical used for
emergency lighting).
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for electrical systems in the
country where the products are installed.
CONFORMITY TO STANDARDS.
LV directive. Standards EN 60598-1, EN 60598-2-22, EN 60598-2-2.
EMC directive. Standards EN 61547, EN 61000-3-2, EN 61000-3-3, EN 55015.
SE SA B A
INHIBITION
SE SA B A
REST MODE
INHIBITION / REST MODE
B A
B
A
bridge
02795
REST CONTROL
02795
POWER
EMERGENCY
STATE
ON
OFF
EMERGENCY
MODE
A
B
Fig. 3
SE
SA
230V~
50Hz
A
B
5 4 3 2 1
6
SE
B
A
230V~
02795
REST MODE
(OPTIONAL)
-
NON MANTAINED (SE)
WIRING DIAGRAMS
REST CONTROL
02795
POWER
EMERGENCY
STATE
ON
OFF
EMERGENCY
MODE
A
B
If the 02795 is available, move the switch on the board as in Fig.3
Always connect the main voltage SE
Fig. 1
SE
SA
230V~
50Hz
A
B
5 4 3 2 1
6
- MANTAINED (SA)
SE
WIRING DIAGRAMS
230V~
50Hz
SA
B
A
230V~
02795
REST MODE
(OPTIONAL)
REST CONTROL
02795
POWER
EMERGENCY
STATE
ON
OFF
EMERGENCY
MODE
A
B
If the 02795 is available, move the switch on
the board as in Fig.3
Always connect the main voltage SE
Fig. 2
COD.
LAMP
AUT.
BATTERY
6W - G5
NiCd 6V 2,5Ah
NiCd 6V 0,8Ah
NiCd 6V 2,5Ah
NiCd 6V 1,3Ah
NiMH 6V 3,3Ah
3h
1h
3h
1h
3h
11W - 2G7
11W - 2G7
FLUX (lm)
FLUX (lm)
SE
SA
78
139
135
195
215
–
–
–
02741
6W - G5
NiCd 6V 0,8Ah
1h
99
–
NiCd 6V 1,3Ah
NiMH 6V 3,3Ah
–
–
8W - G5
8W - G5
8W - G5
8W - G5
1h
3h
142
143
288
290
NiCd 6V 1,8Ah
NiMH 6V 4Ah
NiCd 6V 1,8Ah
NiMH 6V 4Ah
312
294
284
308
445
445
24W - 2G11
24W - 2G11
24W - 2G11
24W - 2G11
1h
3h
1h
3h
BATTERY
12h
12h
12h
12h
12h
24h
12h
24h
12h
24h
12h
24h
POWER
3
3
3
3
3
3
11
11
W
3
3
16
16
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2
02742
02743
02744
02745
02746
02753
02754
02749
02750
02759
02760
Surface mounting emergency lighting device, supply voltage 230 V~ 50 Hz,
rechargeable battery. Provided with lamp.
GENERAL CHARACTERISTICS.
• Power supply: 230 V~ 50 Hz .
• Indicator green Led for the presence of the power supply and for the charge of the battery.
• Indicator yellow led for the inhibition mode.
• Operation with rechargeable Ni-Cd and NiMH batteries.
• Constant current electronic device for the charge of the battery.
• Electrical protection device for the excessive discharge of battery.
• Possibility to be put in the stand-by mode by remote control 02795 (optional)
• Plastic body in accordance with the rules in force.
• Protection degree: IP40.
• Insulating class: II
.
INSTALLATION.
The following procedure must be performed by qualified personnel only.
1) Remove the transparent cover pushing with a screwdriver;
2) Unhook the body of the lamp from the base with a screwdriver;
3) Drill if necessary one of the three possible entries for the power supply cable and fix the base to
the wall using the holes on the base;
4) Make the connections illustrated in figures 1 or 2;
5) Hook the body to the base making release the tooth;
6) Hook the transparent cover to the base making release the tooth.
Important: In the case of flush mounting the product must be installed with the LED facing
uppermost.
BATTERIES
:
It is recommended to substitute each battery every four years or when the nominal autonomy is not
guaranteed. The model and the date of production of the battery are written on it. Fill the field with
the date of the first starting.
Warning: The Ni-Cd and Ni-MH batteries are sold uncharged: the first charge must be 48h long.
WARNING:
Dispose of batteries in the specific differentiated collection bins.
1.
1.
2.
3.
3.
USER INFORMATION IN COMPLIANCE WITH DIRECTIVE 2002/96 (RAEE)
In order to prevent damage to the environment and human health as well as incurring administrative sanctions, appliances
bearing this symbol must be disposed of separately from urban waste, or handed in to the distributor when buying a new
one. Appliances marked with the above symbol must be collected in conformity with the instructions issued by the local
authorities in charge of waste disposal. For more information call the free-phone number 800-862307.