Vimar By-alarm 01722 Manual Download Page 3

Viale Vicenza, 14

36063 Marostica VI - Italy

www.vimar.com

49400900B0  02  1810

!

By-alarm

01722

By-alarm curtain detector, with dual technology, to protect entrances 

and openings such as doors, windows, covered terraces, corridors 

and French doors, surface mounting.

The device is a dual technology curtain sensor with an angle of aperture of 140° 
by 15°. 

CHARACTERISTICS

• Power supply: 12 Vdc ± 30%
• Absorption: 40 mA max
• Microwave: strip 8 dBm 10.525 GHz
• RFI immunity: 0.1 / 500 MHz 3 V/m
• RF transmission power: < 3  mW (5 dBm)
• Alarm time: 3 s
• Operating temperature: - 10..+55 °C
• Ambient humidity: 95%
• Degree of safety: 2 (EN 50131-2-4)
• Ambient class: II (EN 50131-2-4)

LED indicators

• Red: Infrared detection
• Green: Microwave detection
• Red+Green: Alarm

FUNCTIONALITY

• Adjustable range
• Selectable detection sensitivity
• Microstrip microwave 10.525 GHz
• Anti-flicker circuit
• Remote LED viewing
• Installation height up to 4 m
• Sealed optics
• Coverage 140° x 15° for 4 m
• End of line impedance (DEOL) can be selected on board 13 values

LINE BALANCING

The detector is equipped with selectable end-of-line resistors to connect the device 
to control panels with Double Balancing (DEOL).
To achieve Double Balancing, use the corresponding jumpers to select the Tamper 
resistors (series) and Alarm on J1; finally connect the EOL output to the control 
panel zone input.

Caution: By leaving the jumpers open as per factory settings the detector will 
remain configured like any sensor with NC contacts.

Connection for Vimar By-alarm system 

Follow the double balancing instructions depending on the desired mode and 
select values 3k3 for TAMPER and 4k7 for ALARM.

DETECTOR CONFIGURATION

Microwave capacity adjustment

Using the trimmer, set the minimum value, go to the end of the area to protect 
and, with the LEDs off, move your body under the area to protect and check the 
microwave detections via the GREEN LED. 
If the LED does not light up, increase the range by turning the trimmer clockwise 
and repeat the test until you obtain the required conditions.

N.B. The microwave range should always be set to the minimum necessary.

Detection modes

• Low 

sensitivity: SENS jumper open

Detection mode suited for protecting closed entrances or entrances with obsta-
cles that cannot be quickly crossed (e.g. doors, windows, etc.).

• 

High sensitivity: SENS jumper closed

Detection mode suited for protecting open entrances that can be quickly crossed 
(e.g. corridors, etc.). 

Viewing detections 

LED

 jumper open: LED viewing enabled (LED ON) 

LED

 jumper closed: LED viewing disabled (LED OFF) 

If you want to enable viewing the LEDs in LED OFF mode, simply disconnect and 
reconnect the power supply to the detector that will thus go into LED ON mode 
for 40 min.

When powering up the detector in any case goes into LED ON mode for 40 min 
regardless of the settings in order to run the coverage test.

INSTALLATION RULES

• Installation should be carried out by qualified personnel in compliance with the 

current regulations regarding the installation of electrical equipment in the country 
where the products are installed.

• For installation, use halogen-free shielded cables suitable for installation with 

Category 1 power cables (U0 = 400 V) art. 01734.E (2x0.50mm

2

 + 4x0.22mm

2

). 

The length of the connections must not exceed 100 m.

• The device should be mounted horizontally in the middle, at the top of the area to 

be protected, with the lens pointing down. 

It is recommended to never aim the 

sensor with the lens facing upward

.

• Its coverage in width is equal to twice the height of installation (for example, if it is 

in the middle of a window 1 m tall, its width coverage will be 2 m - see Figure 2 in 
COVERAGE DIAGRAMS).

• Remove the front panel and remove the board by pressing on the finger; then cut 

the pre-punched holes on the base and fix the bottom with the two screws and 
plugs. 
In order to increase RFI immunity use a shielded cable with the shielding grounded 
only on the control panel side. 

Finger

• Power up the detector that will then run a self test for 60 s; afterwards, proceed 

with configuration.

STANDARD COMPLIANCE

Standard EN 50131-2-4.
RED directive.
Standards EN 60950-1, EN 50130-4, EN 50130-5, EN 61000-6-3, EN 300 440, EN 
301 489-3 e EN 62479.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU.
The full text of the EU declaration of conformity is on the product sheet available at 
the following Internet address: www.vimar.com.

!

Clarification

AT

BE

BG

CY

HR

DK

EE

FI

FR

DE

EL

IE

IT

LV

LT

LU

MT

NL

PL

PT

GB

CZ

RO

SK

SI

ES

SE

HU

Cable outlet

WEEE - Information for users

If the crossed-out bin symbol appears on the equipment or packaging, this means the pro-
duct must not be included with other general waste at the end of its working life. The user 
must take the worn product to a sorted waste center, or return it to the retailer when pur-
chasing a new one. Products for disposal can be consigned free of charge (without any new 
purchase obligation) to retailers with a sales area of at least 400 m

2

, if they measure less 

than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of 
the used device, or its subsequent recycling, helps avoid the potential negative effects on 
the environment and people’s health, and encourages the re-use and/or recycling of the 
construction materials.

Summary of Contents for By-alarm 01722

Page 1: ...rivelatore che si porterà così nella modalità LED ON per 40 min All accensione il rivelatore entra comunque nella modalità LED ON per 40 min indipedentemente dalle impostazioni per dar modo di effettuare il test di copertura REGOLE DI INSTALLAZIONE L installazione deve essere effettuata da personale qualificato con l osservanza delle disposizioni regolanti l installazione del materiale elettrico i...

Page 2: ...azione visualizzazione led SENS Ponticelli per impostazione sensibilità A EOL DEOL ALARM 12 V TAMPER EOL TAMPER ALARM DEOL LED GATEWATCH B SENS 2K2 Tamper 1K TAMP ALARM M M J1 3K3 4K7 5K6 6K8 6K8 5K6 4K7 3K3 2K2 1K 820 DIAGRAMMI DI COPERTURA COLLEGAMENTI doppio bilanciamento 1 m 4 m 3 m 2 m 1 m 1 m 2 m 3 m 4 m 2 m 3 m 4 m Area di rilevazione Infrarosso Microonda TAMPER S EXT S INT 12V RELÈ 2 ALLAR...

Page 3: ...wing the LEDs in LED OFF mode simply disconnect and reconnect the power supply to the detector that will thus go into LED ON mode for 40 min When powering up the detector in any case goes into LED ON mode for 40 min regardless of the settings in order to run the coverage test INSTALLATION RULES Installation should be carried out by qualified personnel in compliance with the current regulations reg...

Page 4: ...NS Jumpers for setting sensitivity A EOL DEOL ALARM 12 V TAMPER EOL TAMPER ALARM DEOL LED GATEWATCH B SENS 2K2 Tamper 1K TAMP ALARM M M J1 3K3 4K7 5K6 6K8 6K8 5K6 4K7 3K3 2K2 1K 820 COVERAGE DIAGRAMS CONNECTIONS double balancing 1 m 4 m 3 m 2 m 1 m 1 m 2 m 3 m 4 m 2 m 3 m 4 m Detection area Infrared Microwave TAMPER S EXT S INT 12V RELÈ 2 ALLARME RELÈ 1 T T NC NO C NC NO C L 6 L 5 L 4 L 3 L 2 L 1 ...

Reviews: