background image

Viale Vicenza 14

36063 Marostica VI - Italy

www.vimar.com

02973  03  2207

WEEE - User information

The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life must be collected separately 

from other waste. The user must therefore hand the equipment at the end of its life cycle over to the appropriate municipal centres for the 

differentiated collection of electrical and electronic waste. As an alternative to independent management, you can deliver the equipment 

you want to dispose of free of charge to the distributor when purchasing a new appliance of an equivalent type. You can also deliver 

electronic products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a 

sales area of at least 400 m

2

. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal 

of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice 

of reusing and/or recycling materials used in manufacture.

 INSTALLATION RULES.

• Installation and configuration must be carried out by qualified persons in compliance with 

the current regulations regarding the installation of electrical equipment in the country where 
the products are installed.

• The C-NO contact of the relay must be protected against overloads by installing a device, 

fuse or automatic 1-way switch, with a rated current not exceeding 10 A.

• Do not connect a SELV circuit to the C-NO terminals as there is no double insulation on the 

L-N terminals

• The device must be installed in a flush mounting box or surface mounting box with the 

related mounting frames and cover plates, at a height of 1.5 m above floor level, in a suitable 
position for the correct detection of the room temperature, avoiding installation in recesses, 
behind doors and curtains, areas affected by heat sources or subject to the flow of forced 
heating/cooling ventilation sources or affected by atmospheric factors. Avoid in particular 
installation on perimeter walls or in association with devices which generate heat (e.g. 
dimmers or lamps).

CHARACTERISTICS.

• Rated supply voltage: 100-240 V~, 50/60 Hz.
• Dissipated power: 0.55 W.
• RF transmission power: < 100mW (20dBm).
• Frequency range: 2400-2483.5 MHz.
• Terminals:

- 2 terminals (L and N) for line and neutral
- 2 terminals for external temperature probe (art. 02965.1 and 20432-19432-14432) 

Maximum length of the external sensor connection cable: 10 m.
Use a twisted cable with a minimum cross-section of 0.5 mm

2

 (art. 01840).

- 2 C-NO relay terminals.

• Relay output with voltage-free contact: 5(2) A 240 V~
• Input for external sensor (art. 02965.1-20432-19432-14432) with the following functions: XX

-  replacement of the internal sensor
-  average with the internal one
-  screed temperature limitation

• Current settable setpoint: 4°C - 40°C.
• Temp. measurement precision (integrated probe): 0.5°C b15°C and 30°C, 0.8°C at 

the extremes

• For use for Heating/Air Conditioning (winter/summer).
• Operating modes: Automatic, Manual, Reduction, Absence, Protection, Off, Timed Manual
• Temperature control algorithms: ON/OFF or configurable PID
• 4 front buttons for control and configuration/reset
• RGB LED for configuration status (flashing blue) and output status (configurable colour) sig-

nalling

• Operating temperature: T40 (0 °C +40 °C) (indoor use)
• Protection degree: IP30
• ErP classification (EU Reg. 811/2013): - ON/OFF: class I, contribution 1%. - PID: class IV, 

contribution 2%.

• Device in class II
• Number of manual cycles: 3,000
• Number of automatic cycles: 100,000
• Type of contact opening: micro-disconnection
• Type of action: 1BU
• Tracking index: PTI175
• State of pollution: 2 
• Rated pulse voltage: 4000 V
• Software class: A
• Reading resolution: 0.1 °C 
• Settings resolution: 0.1 °C 
• Update of temperature displayed: every 10 s 
• Room temperature display: 0 °C +40 °C
• Hysteresis adjustable via App: from 0.1 °C to 1 °C 
• Hourly temperature setting (via App)
• Room temperature during transportation: -25 °C +60 °
• Clock error: ≤ 1 s per day
• With the View Wireless App, the Installer configures the thermostat and creates climate 

control programmes.

• With the View Wireless App and the View App, the Administrator creates or modifies climate 

control programmes.

• Controllable via View App, Alexa, Google, Siri and Homekit voice assistantfor

OPERATION.

In Bluetooth technology mode, the device should configured using the View Wireless App. 
The App can be used to set the following parameters:
• Lighting in standby: high, medium, low, off; default = medium
• Circular ring indication selection: automatic or monochrome; default = automatic
• RGB colour selection: in the event of monochrome, possibility of setting the colour
• Temperature calibration for heating: between -5°C and +5°C with default = 0°C
• Temperature calibration for air conditioning: between -5°C and +5°C with default = 0°C
• External probe use: deactivated, average with the internal one, replacing the internal one; 

default = deactivated

• Relay output status: normally open, normally closed; default = normally open
• Control type: On/Off, PID; default = On/Off

• Hysteresis for On/Off control: between 0.1°C and 1°C; default = 0.2°C
• Proportional band for PID control: between 0.5°C and 5°C; default = 3°C
• Integrative time for PID control: between 5 min and 120 min; default = 20 min
• Derivative time for PID control: between 0 and 255 s, disabled; default = 0
• Cycle time for PID control: between 10 min and 30 min; default = 10 min
The View Wireless App can also be used to associate a magnetic or wired contact of art. 
03980 to turn off the temperature control system in the event of an open window; in this case, 
the time for reaction and reactivation of contact opening and closing can be set:
• Reaction time: between 0 minutes (instantaneous) and 30 minutes; default = 0 minutes
•  Reactivation time (time after which the thermostat is reactivated even without closing the 

window): between 0 (disabled) and 12 hours; default = 1 hour.

The View App can be used to set: 
• Time schedules (times and temperature levels T1, T2 and T3)
• Setpoint for all operating modes (Manual, Reduction, Absence, Protection)
• Manual operation time: between 1 min and 23 hours (with 1-min steps); default = 60 min

USE.

The front buttons, the display, the dial and the lighting of the circular ring around the display 
can be used to set and display all the operating modes of the thermostat.
Use the dial to set a new setpoint. In particular, for operation in Bluetooth technology: 
- in automatic operating mode, turn the dial for the thermostat to switch to manual operation 

for a period of time which can be set on the View App; 

- in manual operation or reduction mode, the thermostat remains in this mode and the setpoint 

is that set on the dial.

REGULATORY COMPLIANCE.

RED Directive. RoHS directive. ErP directive.
EN 60730-2-7, EN 60730-2-9, EN 301 489-17, EN 300 328, EN 62479, EN 63000 standards.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text 
of the EU declaration of conformity is on the product sheet available on the following website: 
www.vimar.com
Temperature control device regulation (EU) no. 811/2013.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.

The Apple, iPhone and iPad logos are trademarks of Apple Inc., registered in the United States and in other Countries 
and Regions. App Store is a service trademark of Apple Inc. Google is a trademark of Google LLC. Amazon, Alexa and 
all related logos are trademarks of Amazon.com, Inc. or its affiliates.

Reviews: