7.3  Access to the motor fan

JBRB ECOWATT

®

 VCHV PR 04 to 38

JBRB ECOWATT

®

 PR VCHV 48 to 92

To access all the compartments of the unit, unlock the 4 toggles, then remove the top of the unit using the 
handles. The suction, discharge and motor compartments are fully accessible for cleaning.

Summary of Contents for JBRB ECOWATT PR VCHV

Page 1: ...ATION WIRING COMMISSIONING MAINTENANCE AFNOR CERTIFICATION ISO 14001 Environnement AFNOR CERTIFICATION ISO 9001 Q u a l i t JBRB ECOWATT PR VCHV VMC Collective housing Tertiary premises ventilation Ap...

Page 2: ...5 ELECTRIC CONNECTION 14 5 1 Preliminary precautions 14 5 2 Electrical characteristics 15 5 3 Electrical connection of the proximity switch 15 5 4 Electrical connection of the Start Stop command 16 5...

Page 3: ...orrosive chemicals 1 2 Safety instructions Wear the appropriate PPE Personal Protective Equipment before any work is carried out Before installing the ventilation unit make sure that the support and t...

Page 4: ...s sizes 48 to 92 High performance reaction turbine in galvanized steel INTZ padlockable proximity switch mounted wired ECM direct current motor out of the air stream 04 to 22 IP44 class B single phase...

Page 5: ...maintain a constant pressure in the network The pressure set point is adjustable from the control buttons of the VCHV control box The operation is fully automatic This mode of operation is programmed...

Page 6: ...abs 100 0 500 1000 1500 2000 2500 Qv m3 h 0 50 100 150 200 250 300 350 400 P W abs JBRB ECOWATT PR VCHV 30 JBRB ECOWATT PR VCHV 38 100 Qv m3 h P Pa stat 0 100 200 300 400 500 600 700 0 500 1000 1500 2...

Page 7: ...000 5000 6000 0 200 400 600 800 1000 1200 1400 P W abs Qv m3 h 100 0 1000 2000 3000 4000 5000 6000 7000 8000 JBRB ECOWATT PR VCHV 82 JBRB ECOWATT PR VCHV 92 100 P Pa stat 0 100 200 300 400 500 600 0 1...

Page 8: ...WATT PR 22 767 683 701 511 355 709 661 252 237 252 239 45 JBRB ECOWATT PR 30 1019 820 873 568 400 892 797 267 271 267 271 64 JBRB ECOWATT PR 38 1153 938 971 631 500 1036 907 306 331 306 331 78 IS vers...

Page 9: ...47 267 271 67 JBRB ECOWATT PR 38 1468 1024 631 500 400 1396 908 306 281 306 331 83 IS version 27 mm JBRB ECOWATT PR VCHV 48 70 82 92 Horizontal discharge Configuration D D2 D2 F B C F I J C B Directio...

Page 10: ...22 756 683 701 511 355 709 661 252 237 45 JBRB ECOWATT PR 30 973 820 873 565 400 892 797 267 271 64 JBRB ECOWATT PR 38 1106 938 971 637 500 1036 907 306 331 78 IS version 27 mm JBRB ECOWATT PR VCHV 48...

Page 11: ...276 930 566 400 355 1238 797 267 247 67 JBRB ECOWATT PR 38 1426 1025 637 500 400 1396 909 306 281 83 IS version 27 mm JBRB ECOWATT PR VCHV 48 70 82 92 Refoulement vertical Configuration D C B D2 D2 F...

Page 12: ...han dles are only used to open the lid of the cabinet JBRB ECOWATT PR VCHV 04 to 38 JBRB ECOWATT PR VCHV 48 to 92 3 3 Choice of location JBRB ECOWATT PR VCHV 04 to 38 JBRB ECOWATT PR VCHV 48 to 92 C...

Page 13: ...rge allowed if connected to an air duct system The fixing method of the unit must be dimen sioned in such a way as to ensure that it is held securely in the event of a fire 3 5 Assembly of accessories...

Page 14: ...oud 90 doubleaspiration 90 M Orientation rejet horizontal Orientation rejet vertical Enligne L Doubleaspiration D Modulablecoud 90 doubleaspiration 90 M Orientation rejet horizontal Orientation rejet...

Page 15: ...ECOWATT PR VCHV 30 0 60 2 6 0 60 1 2 JBRB ECOWATT PR VCHV 38 0 70 3 1 0 70 1 3 JBRB ECOWATT PR VCHV 48 0 72 3 1 0 72 1 5 JBRB ECOWATT PR VCHV 70 1 24 5 4 1 24 2 6 JBRB ECOWATT PR VCHV 82 1 40 6 0 JBR...

Page 16: ...the diagrams for switching from factory wiring to adding an on off command 5 4 1 JBRB ECOWATT PR VCHV 04 to 22 models Factory wiring Adding the start stop command 24V 0 10V Out Gnd 0 20mA out N L V Gn...

Page 17: ...1 VCHV Controller VENTIDRIVE EC motor controller 5 5 Connection of the pressure switch Open the door of the unit by unscrewing the 2 screws with a 13 mm wrench Pass the cable through the 2nd cable gl...

Page 18: ...ts maximum rotation speed to ex tract the smoke At this time for unit sizes 04 to 22 an auxiliary fan will start up to cool the motorized fan of the C4 unit A push button on the side of the unit allow...

Page 19: ...e motor fan JBRB ECOWATT VCHV PR 04 to 38 JBRB ECOWATT PR VCHV 48 to 92 To access all the compartments of the unit unlock the 4 toggles then remove the top of the unit using the handles The suction di...

Page 20: ...otor turbine assembly then remove the motor turbine assembly Put in position the new motor turbine assembly on the 2 lugs Screw the 4 screws M8x20 without tightening them Screw the 2 M8x80 screws into...

Page 21: ...cable from the switch Unlock the 4 toggles then remove the top of the unit using the handles Disconnect the 2 quick connectors on the command support B 1 1 Unscrew the screw inside the command part t...

Page 22: ...ontroller for JBRB ECOWATT 38 three phase 1571210002 Controller 1 VENTIDRIVE 0 7kW Controller for JBRB ECOWATT 48 single phase 1571250003 Controller 1 VENTIDRIVE 1 5kW Controller for JBRB ECOWATT 48 t...

Page 23: ...23 24 NT00000749 JBRB ECOWATT PR VCHV AN 211115...

Page 24: ...ncern of improvement of the material the manufacturer reserves the right to proceed without notice to any technical modification VIM Les pr s de M gy Sud SOUDAN CS 60120 79401 ST MAIXENT L ECOLE CEDEX...

Reviews: